128 research outputs found

    Microwave radiation induced magneto-oscillations in the longitudinal and transverse resistance of a two dimensional electron gas

    Full text link
    We confirm the existance of magneto-resistance oscillations in a microwave-irradiated two-dimensional electron gas, first reported in a series of papers by Zhudov et al. and Mani et al. In our experiments, on a sample with a more moderate mobility, the microwave induced oscillations are observed not only in the longitudinal - but also in the transverse-resistance (Hall resistance). The phase of the oscillations is such that the decrease (increase) in the longitudinal resistance is accompanied by an increase (decrease) in the absolute value of the Hall resistance. We believe that these new results provide valuable new information to better understand the origin of this interesting phenomenon.Comment: Accepted for publication in journal of Solid State Comunication

    Measuring service quality of public dental health care facilities in Kelantan, Malaysia

    Get PDF
    This study investigates patients' expectations and perceptions of service quality in public dental health care and measures their "satisfaction gap." This descriptive study involved 481 dental outpatients in Kelantan, Malaysia. A modified SERVQUAL 20-item instrument was used to assess patients' expectations before and perceptions after receiving dental treatment. The "satisfaction gap" was then measured. Results showed that patients visiting for management of dental pain were more satisfied (P = .007) than those visiting with appointment. The most significant service quality dimensions were related to responsiveness, assurance, and empathy of the dental health care providers. There was a significant difference between the patients' expectations and their perceptions of service provided (P < .01) with regard to all dimensions. In conclusion, dental service providers should give emphasis to the compassionate and emotional aspects of care and to remember that they are integral components of quality service

    The microwave induced resistance response of a high mobility 2DEG from the quasi-classical limit to the quantum Hall regime

    Full text link
    Microwave induced resistance oscillations (MIROs) were studied experimentally over a very wide range of frequencies ranging from ~20 GHz up to ~4 THz, and from the quasi-classical regime to the quantum Hall effect regime. At low frequencies regular MIROs were observed, with a periodicity determined by the ratio of the microwave to cyclotron frequencies. For frequencies below 150 GHz the magnetic field dependence of MIROs waveform is well described by a simplified version of an existing theoretical model, where the damping is controlled by the width of the Landau levels. In the THz frequency range MIROs vanish and only pronounced resistance changes are observed at the cyclotron resonance. The evolution of MIROs with frequency are presented and discussed.Comment: 4 pages, presented at EP2DS, to be published in Physica

    Radiation-induced oscillatory magnetoresistance as a sensitive probe of the zero-field spin splitting in high mobility GaAs/AlGaAs devices

    Get PDF
    We suggest an approach for characterizing the zero-field spin splitting of high mobility two-dimensional electron systems, when beats are not readily observable in the Shubnikov-de Haas effect. The zero-field spin splitting and the effective magnetic field seen in the reference frame of the electron is evaluated from a quantitative study of beats observed in radiation-induced magnetoresistance oscillations.Comment: 4 pages, 4 color figure

    Denture marking: a mandatory procedure to aid forensic identification

    Get PDF
    Purpose - The purpose of this paper is to highlight the significance of placing identification marks on dentures. Design/methodology/approach - This paper reviews the legislation with regard to denture marking in certain countries, various methods of denture marking and describes a simple, inexpensive, paper-based labelling system. Findings - Various methods have been proposed for denture marking but it is important to use a method that is simple, practical, affordable and universally acceptable. Practical implications - The identification of unknown or missing persons by means of denture marking is a very successful method of identification in forensic investigation. It is also useful for patients residing in hospitals and community homes where dentures could be misplaced, particularly during cleaning by personnel where there is a chance of loss or mix-up. The importance of denture marking should be emphasized by all law-enforcing authorities and should be promoted among all dentists, towards making it a compulsory routine dental procedure throughout the world. Originality/value - In Malaysia, denture marking, as recommended by its Ministry of Health, uses a unique coding system which can readily provide information about the wearer in whichever part of the world the person is found. The method applied is simple, practical and affordable and can easily be adapted by others. It can be of great value during times of crisis

    Rapid and deep-scale ubiquitylation profiling for biology and translational research

    Get PDF
    Protein ubiquitylation is involved in a plethora of cellular processes. While antibodies directed at ubiquitin remnants (K-ɛ-GG) have improved the ability to monitor ubiquitylation using mass spectrometry, methods for highly multiplexed measurement of ubiquitylation in tissues and primary cells using sub-milligram amounts of sample remains a challenge. Here, we present a highly sensitive, rapid and multiplexed protocol termed UbiFast for quantifying ~10,000 ubiquitylation sites from as little as 500 μg peptide per sample from cells or tissue in a TMT10plex in ca. 5 h. High-field Asymmetric Waveform Ion Mobility Spectrometry (FAIMS) is used to improve quantitative accuracy for posttranslational modification analysis. We use the approach to rediscover substrates of the E3 ligase targeting drug lenalidomide and to identify proteins modulated by ubiquitylation in models of basal and luminal human breast cancer. The sensitivity and speed of the UbiFast method makes it suitable for large-scale studies in primary tissue samples

    Far-infrared photo-conductivity of electrons in an array of nano-structured antidots

    Full text link
    We present far-infrared (FIR) photo-conductivity measurements for a two-dimensional electron gas in an array of nano-structured antidots. We detect, resistively and spectrally resolved, both the magnetoplasmon and the edge-magnetoplasmon modes. Temperature-dependent measurements demonstrates that both modes contribute to the photo resistance by heating the electron gas via resonant absorption of the FIR radiation. Influences of spin effect and phonon bands on the collective excitations in the antidot lattice are observed.Comment: 5 pages, 3 figure

    Clusters in the inner spiral arms of M51: the cluster IMF and the formation history

    Get PDF
    We study the cluster population in a region of 3.2x3.2 kpc^2 in the inner spiral arms of the intergacting galaxy M51, at a distance of about 1 to 3 kpc from the nucleus, based on HST--WFPC2 images taken through five broadband and two narrowband filters. We found 877 cluster candidates and we derived their ages, initial masses and extinctions by comparing their energy distribution with the Starburst99 cluster models. We describe the 3 and 2-dimensional least-square energy fitting method that was used (3DEF, 2DEF). The lack of [OIII] emission in even the youngest clusters with strong H-alpha emission, indicates the absence of the most massive stars and suggests a mass upper limit of about 25 to 30 solar masses. The mass versus age distribution of the clusters shows a drastic decrease in the number of clusters with age, which indicates that cluster disruption is occurring on a timescale of about 10 Myr for low mass clusters. The cluster initial mass function for clusters younger than 10 Myr has an exponent of alpha = 2.0 (+- 0.05) We derived the cluster formation history from clusters with an initial mass larger than 10^4 solar masses. There is no evidence for a peak in the cluster formation rate within a factor two at about 200 to 400 Myr ago, i.e. at the time of the interaction with the companion galaxy NGC 5194.Comment: 15 pages, 15 figures. Accepted for publication by Astronomy and Astrophysic

    Magnetotransport in two-dimensional electron gas at large filling factors

    Full text link
    We derive the quantum Boltzmann equation for the two-dimensional electron gas in a magnetic field such that the filling factor ν1\nu \gg 1. This equation describes all of the effects of the external fields on the impurity collision integral including Shubnikov-de Haas oscillations, smooth part of the magnetoresistance, and non-linear transport. Furthemore, we obtain quantitative results for the effect of the external microwave radiation on the linear and non-linear dcdc transport in the system. Our findings are relevant for the description of the oscillating resistivity discovered by Zudov {\em et al.}, zero-resistance state discovered by Mani {\em et al.} and Zudov {\em et al.}, and for the microscopic justification of the model of Andreev {\em et al.}. We also present semiclassical picture for the qualitative consideration of the effects of the applied field on the collision integral.Comment: 28 pages, 19 figures; The discussion of the role of the effect of the microwave field on the distribution function is revised (see also cond-mat/0310668). Accepted in Phys. Rev.
    corecore