25 research outputs found

    Compatible Transformations for a Qudit Decoherence-free/Noiseless Encoding

    Full text link
    The interest in decoherence-free, or noiseless subsystems (DFS/NSs) of quantum systems is both of fundamental and practical interest. Understanding the invariance of a set of states under certain transformations is mutually associated with a better understanding of some fundamental aspects of quantum mechanics as well as the practical utility of invariant subsystems. For example, DFS/NSs are potentially useful for protecting quantum information in quantum cryptography and quantum computing as well as enabling universal computation. Here we discuss transformations which are compatible with a DFS/NS that is composed of d-state systems which protect against collective noise. They are compatible in the sense that they do not take the logical (encoded) states outside of the DFS/NS during the transformation. Furthermore, it is shown that the Hamiltonian evolutions derived here can be used to perform universal quantum computation on a three qudit DFS/NS. Many of the methods used in our derivations are directly applicable to a large variety of DFS/NSs. More generally, we may also state that these transformations are compatible with collective motions.Comment: 30 pages, replaced with published versio

    Quantum key distribution based on orthogonal states allows secure quantum bit commitment

    Full text link
    For more than a decade, it was believed that unconditionally secure quantum bit commitment (QBC) is impossible. But basing on a previously proposed quantum key distribution scheme using orthogonal states, here we build a QBC protocol in which the density matrices of the quantum states encoding the commitment do not satisfy a crucial condition on which the no-go proofs of QBC are based. Thus the no-go proofs could be evaded. Our protocol is fault-tolerant and very feasible with currently available technology. It reopens the venue for other "post-cold-war" multi-party cryptographic protocols, e.g., quantum bit string commitment and quantum strong coin tossing with an arbitrarily small bias. This result also has a strong influence on the Clifton-Bub-Halvorson theorem which suggests that quantum theory could be characterized in terms of information-theoretic constraints.Comment: Published version plus an appendix showing how to defeat the counterfactual attack, more references [76,77,90,118-120] cited, and other minor change

    Performance of three small-scale wastewater treatment plants. A challenge for possible re use

    No full text
    The study focused on the assessment of the performance of three WWTPs in Greece by the estimation of the microbiological and chemical quality of influent and effluent sewage. Physicochemical parameters were recorded (temperature, pH, COD, BOD, suspended solids, conductivity), and meteorological data were collected (air temperature, rain). Microbiological parameters were analyzed (Escherichia coli, total coliforms, bacteriophages, Salmonella, human adenoviruses, Candida, Pseudallescheria boydii, helminths, parasites Cryptosporidium ssp., and Giardia spp.). Statistically significant correlations among the various aforementioned parameters were investigated, in an attempt to propose appropriate processing performance indicators. Furthermore, the study aimed to assess current joint ministerial decision (JMD) on wastewater reuse, for irrigation purposes; to evaluate its practicability and its potential for public health protection. In the vast majority, outlet samples from all three studied WWTPs were not appropriate for irrigation reuse purposes based on BOD50 and suspended solids limit values, set by the current JMD, for both limited and unrestricted irrigation applications. Reductions for E. coli, total coliforms, and bacteriophages were found to range between 2–3, 1.5–2.5, and 2–4 log10 values, respectively. Salmonella spp. was detected in outlet sewage samples from Patra (PAT), Arachova (ARH), and Livadeia (LEV), at 23 % (3/13), 33 % (4/12), and 38 % (5/13), respectively. Molds were detected at 92.3 % (12/13), 100 % (13/13), and 91.6 % (11/12), respectively, while Candida was found at 85 % (11/13), 67 % (8/12), and 46 % (6/13). A high prevalence of Pseudallescheria boydii, in outlet samples from all studied WWTPs is an important public health issue, which underlines the need for further studies on this emerging fungal pathogen in wastewater reuse applications. Pseudallescheria boydii was found at 85 % (11/13), 67 % (8/12), and 46 % (6/13), respectively. Helminths were found in both inlet and outlet samples, of all studied WWTPs, at 100 %. Human adenoviruses, were detected at high percentages in outlet samples at 76.9 % (10/13), 92.3 % (12/13), 84.6 % (11/13), respectively, while no influence of UV irradiation was recorded on the entry and exit loads of human adenoviruses. No influence of meteorological parameters was found on the microbiological and chemical parameters, with the exception of a weak positive correlation between environmental temperature and bacteriophages. A moderate positive correlation was found between BOD and suspended solids, bacteriophages, and total coliforms, bacteriophages and E. coli, and bacteriophages and adenoviruses. A significant positive correlation was found between total coliforms and E. coli, COD and BOD, and suspended solids and COD. No correlations were proved between human pathogens and bacterial indicator parameters. Collectively, our findings underlined the unsuitability of the current JMD on wastewater reuse in Greece, or public health protection. The study is expected to support the development of a public health risk assessment model based on quantitative risk assessment on the use of treated wastewater for irrigation purposes in Greece. © 2015, Springer-Verlag Berlin Heidelberg

    Attitudes of general dental practitioners in Europe to the microbial risk associated with dental unit water systems

    No full text
    Dental Unit Water Systems (DUWS) are used in dental practices to provide water for cooling of dental equipment and irrigation of the oral cavity. However, they have been demonstrated to be contaminated with micro-organisms. There are currently no European Union (EU) Commission guidelines for the microbial quality of water discharged by DUWS. This study was part of an EU research programme to investigate the microbial contamination of DUWS in general dental practice (GDP) in the UK, Denmark, Germany, The Netherlands, Ireland, Greece and Spain. To undertake a questionnaire survey on the type of DUWS in use and determine the attitude of GDPs to the risk of microbial infection from DUWS. The questionnaire was written and translated into the language of each country before being posted to each participating dentist. Dentists were asked to complete the questionnaire survey and return it by post. The major findings were that the majority of dentists did not clean, disinfect or determine the microbial load of their DUWS, and that dentists would welcome regular monitoring and advice on maintaining their DUWS; the introduction of guidelines; and recommendations on controlling the microbial load of DUW

    Comparison of the Efficacies of Disinfectants To Control Microbial Contamination in Dental Unit Water Systems in General Dental Practices across the European Union

    No full text
    Water delivered by dental unit water systems (DUWS) in general dental practices can harbor high numbers of bacteria, including opportunistic pathogens. Biofilms on tubing within DUWS provide a reservoir for microorganisms and should be controlled. This study compared disinfection products for their ability to meet the American Dental Association's guideline of <200 CFU · ml(−1) for DUWS water. Alpron, BioBlue, Dentosept, Oxygenal, Sanosil, Sterilex Ultra, and Ster4Spray were tested in DUWS (n = 134) in Denmark, Germany, Greece, Ireland, The Netherlands, Spain, and the United Kingdom. Weekly water samples were tested for total viable counts (TVCs) on yeast extract agar, and, where possible, the effects of products on established biofilm (TVCs) were measured. A 4- to 5-week baseline measurement period was followed by 6 to 8 weeks of disinfection (intermittent or continuous product application). DUWS water TVCs before disinfection ranged from 0 to 5.41 log CFU · ml(−1). Disinfectants achieved reductions in the median water TVC ranging from 0.69 (Ster4Spray) to 3.11 (Dentosept) log CFU · ml(−1), although occasional high values (up to 4.88 log CFU · ml(−1)) occurred with all products. Before treatment, 64% of all baseline samples exceeded American Dental Association guidelines, compared to only 17% following commencement of treatment; where tested, biofilm TVCs were reduced to below detectable levels. The antimicrobial efficacies of products varied (e.g., 91% of water samples from DUWS treated with Dentosept or Oxygenal met American Dental Association guidelines, compared to 60% of those treated with Ster4Spray). Overall, the continuously applied products performed better than those applied intermittently. The most effective products were Dentosept and Oxygenal, although Dentosept gave the most consistent and sustained antimicrobial effect over time

    A study of the evolution of the third COVID-19 pandemic wave in the Athens metropolitan area, Greece, through two cross-sectional seroepidemiological surveys: March, June 2021

    No full text
    We studied the third coronavirus disease 2019 (COVID-19) pandemic wave in Athens metropolitan area (3 738 901 inhabitants) through two seroepidemiological surveys. Persons presenting in 12 healthcare facilities across Athens in March and June 2021 were studied (764 and 901, respectively). Immunoglobulin G antibodies against severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) spike protein were measured by a chemiluminescent microparticle immunoassay. In March the seroprevalence rate was 11.6%, meaning that 435 208 residents of Athens had evidence of immunity. The respective values in June were 55.7% and 2 082 568 residents. The highest seroprevalence rates attributed to SARS-CoV-2 infection were recorded in persons &lt;18 years (16.3% in March and 31.6% in June), while immunity was mainly vaccine-induced in persons 18–64 years and &gt;65 years. Infection-attributed immunity also increased in older-age groups. Wide ranges in seroprevalence rates were noted across areas in March and June. The highest seroprevalence rates were recorded in Piraeus (47.2%) and West Attica (37.5%). However, the highest increase (&gt;5 times) occurred in Piraeus and the South Section of Athens, which are among the most densely populated areas in Athens. In both study periods, history of COVID-19 or febrile episode, and having a cohabitant with COVID-19 were associated with increased risk for seropositivity among unvaccinated persons (p values &lt;0.001 for all). Residing in Piraeus, the South Section or West Attica was associated with increased risk for seropositivity in June (p values &lt;0.001). Wide heterogeneity in seroprevalence rates was found across areas in Athens, which is mainly attributed to population density. The impact of population mobility and socioeconomic status should be explored. © 2021 Wiley Periodicals LLC
    corecore