14 research outputs found

    Molecular Imaging of Pulmonary Tuberculosis in an Ex-Vivo Mouse Model Using Spectral Photon-Counting Computed Tomography and Micro-CT

    Get PDF
    Assessment of disease burden and drug efficacy is achieved preclinically using high resolution micro computed tomography (CT). However, micro-CT is not applicable to clinical human imaging due to operating at high dose. In addition, the technology differences between micro-CT and standard clinical CT prevent direct translation of preclinical applications. The current proof-of-concept study presents spectral photon-counting CT as a clinically translatable, molecular imaging tool by assessing contrast uptake in an ex-vivo mouse model of pulmonary tuberculosis (TB). Iodine, a common contrast used in clinical CT imaging, was introduced into a murine model of TB. The excised mouse lungs were imaged using a standard micro-CT subsystem (SuperArgus) and the contrast enhanced TB lesions quantified. The same lungs were imaged using a spectral photoncounting CT system (MARS small-bore scanner). Iodine and soft tissues (water and lipid) were materially separated, and iodine uptake quantified. The volume of the TB infection quantified by spectral CT and micro-CT was found to be 2.96 mm(3) and 2.83 mm(3), respectively. This proof-of-concept study showed that spectral photon-counting CT could be used as a predictive preclinical imaging tool for the purpose of facilitating drug discovery and development. Also, as this imaging modality is available for human trials, all applications are translatable to human imaging. In conclusion, spectral photon-counting CT could accelerate a deeper understanding of infectious lung diseases using targeted pharmaceuticals and intrinsic markers, and ultimately improve the efficacy of therapies by measuring drug delivery and response to treatment in animal models and later in humans

    A hybrid 2D/3D user interface for radiological diagnosis

    Get PDF
    This paper presents a novel 2D/3D desktop virtual reality hybrid user interface for radiology that focuses on improving 3D manipulation required in some diagnostic tasks. An evaluation of our system revealed that our hybrid interface is more efficient for novice users and more accurate for both novice and experienced users when compared to traditional 2D only interfaces. This is a significant finding because it indicates, as the techniques mature, that hybrid interfaces can provide significant benefit to image evaluation. Our hybrid system combines a zSpace stereoscopic display with 2D displays, and mouse and keyboard input. It allows the use of 2D and 3D components interchangeably, or simultaneously. The system was evaluated against a 2D only interface with a user study that involved performing a scoliosis diagnosis task. There were two user groups: medical students and radiology residents. We found improvements in completion time for medical students, and in accuracy for both groups. In particular, the accuracy of medical students improved to match that of the residents

    MARS-MD: Rejection based image domain material decomposition

    Get PDF
    This paper outlines image domain material decomposition algorithms that have been routinely used in MARS spectral CT systems. These algorithms (known collectively as MARS-MD) are based on a pragmatic heuristic for solving the under-determined problem where there are more materials than energy bins. This heuristic contains three parts: (1) splitting the problem into a number of possible sub-problems, each containing fewer materials; (2) solving each sub-problem; and (3) applying rejection criteria to eliminate all but one sub-problem's solution. An advantage of this process is that different constraints can be applied to each sub-problem if necessary. In addition, the result of this process is that solutions will be sparse in the material domain, which reduces crossover of signal between material images. Two algorithms based on this process are presented: the Segmentation variant, which uses segmented material classes to define each sub-problem; and the Angular Rejection variant, which defines the rejection criteria using the angle between reconstructed attenuation vectors

    Reducing beam hardening effects and metal artefacts in spectral CT using Medipix3RX

    No full text
    MARS Spectral DataStudies on beam hardening and metal artefact reduction using Medipix All Resolution System (MARS) spectral scanner were carried out. Four datasets are provided - titanium phantom, titanium scaffold, magnesium scaffold and titanium mesh. Each of these datasets are organized as raw data, preprocessed and MARS-ART reconstruction. The 'RAW DATA' directory contains dicom files representing darkfield images, open beam images and raw projection images. The 'PREPROCESSED' directory contains darkfield corrected, normalized and ring-filtered projection images in tif format. The 'MARS-ART RECONSTRUCTION' directory contains full volume reconstruction in tif format for all the energy bins using algebraic reconstruction technique. Projections are taken for every camera position during the spectral scans and MARS-ART software directly operates on unstitched projections. The geometrical information for every projection image can be accessed from the dicom tags associated with each dicom file

    MARS pre-clinical imaging: the benefits of small pixels and good energy data

    No full text
    Images from MARS spectral CT scanners show that there is much diagnostic value from using small pixels and good energy data. MARS scanners use energy-resolving photon-counting CZT Medipix3RX detectors that measure the energy of photons on a five-point scale and with a spatial resolution of 110 microns. The energy information gives good material discrimination and quantification. The 3D reconstruction gives a voxel size of 70 microns. We present images of pre-clinical specimens, including excised atheroma, bone and joint samples, and nanoparticle contrast agents along with images from living humans. Images of excised human plaque tissue show the location and extent of lipid and calcium deposition within the artery wall. The presence of intraplaque haemorrhage, where the blood leaks into the artery wall following a rupture, has also been visualised through the detection of iron. Several clinically important bone and joint problems have been investigated including: site-specific bone mineral density, bone-metal interfaces (spectral CT reduces metal artefacts), cartilage health using ionic contrast media, gout and pseudogout crystals, and microfracture assessment using nanoparticles. Metallic nanoparticles have been investigated as a cellular marker visible in MARS images. Cell lines of different cancer types (Raji and SK-BR3) were incubated with monoclonal antibody-functionalised AuNPs (Herceptin and Rituximab). We identified and quantified the labelled AuNPs demonstrating that Herceptin-functionalised AuNPs bound to SK-BR3 breast cancer cells but not to the Raji lymphoma cells. In vivo human images show the bone microstructure. Fat, water, and calcium concentrations are quantifiable

    Assessment of metal implant induced artefacts using photon counting spectral CT

    No full text
    The aim is to perform qualitative and quantitative assessment of metal induced artefacts of small titanium biomaterials using photon counting spectral CT. The energy binning feature of some photon counting detectors enables the measured spectrum to be segmented into low, mid and high energy bins in a single exposure. In this study, solid and porous titanium implants submerged in different concentrations of calcium solution were scanned using the small animal MARS photon counting spectral scanner equipped with a polyenergetic X-ray source operated at 118 kVp. Five narrow energy bins (7-45 keV, 45-55 keV, 55-65 keV, 65-75 keV and 75-118 keV) in charge summing mode were utilised. Images were evaluated in the energy domain (spectroscopic images) as well as material domain (material segmentation and quantification). Results show that calcium solution outside titanium implants can be accurately quantified. However, there was an overestimation of calcium within the pores of the scaffold. This information is critical as it can severely limit the assessment of bone ingrowth within metal structures. The energy binning feature of the spectral scanner was exploited and a correction factor, based on calcium concentrations adjacent to and within metal structures, was used to minimise the variation. Qualitative and quantitative evaluation of bone density and morphology with and without titanium screw shows that photon counting spectral CT can assess bone-metal interface with less pronounced artefacts. Quantification of bone growth in and around the implants would help in orthopaedic applications to determine the effectiveness of implant treatment and assessment of fracture healing
    corecore