9 research outputs found

    Total hip replacement. Results of a postal survey of current practice on the cement fixation of the acetabular cup in the UK

    Get PDF
    Previous finite element studies and laboratory investigations on reconstructed acetabulum joints show that long-term fixation of the acetabular cup in total hip replacements (THRs) is influenced by surgical fixation techniques. The aim of this study is to determine and understand the reasons of current practice in the cement fixation of the acetabular cup in THRs in the UK. Following a pilot study, a postal survey was carried out among 1350 orthopaedic consultants. Response rate was 40% and data obtained from the returned questionnaires provided information about the current practice of 431 consultants with an average of 16.5 years of experience and who perform an average of 55 cemented THR operations annually. The survey showed wide variations in the fixation methods of the acetabular component. 95% of the respondents use cement to fix the acetabular cup, 46% maintain the subchondral bone and 63 % use a flanged acetabular cup. The numbers of anchorage holes drilled vary from zero to thirty-six and drill diameters vary from 2 to 15 mm. Anchorage hole depths vary from 3 to 20 mm. Given the variability of surgical fixation methods, further studies need to be carried out to determine how fixation techniques could be improved to increase the longevity of the acetabular component in THRs. Further investigations could lead to a better understanding of the factors that contribute to the stability of THRs

    Cement Gun Performance Matters

    No full text

    In Vivo Assessment of Bone Ingrowth Potential of Three-Dimensional E-Beam Produced Implant Surfaces and the Effect of Additional Treatment by Acid Etching and Hydroxyapatite Coating

    Get PDF
    The bone ingrowth potential of three-dimensional E-beam-produced implant surfaces was examined by histology and compared to a porous plasma-sprayed control. The effects of acid etching and a hydroxyapatite (HA) coating were also evaluated by histology. Specimens were implanted in the distal femur of 10 goats. Histological analysis of bone ingrowth was performed 6 weeks after implantation. The E-beam-produced surfaces showed significantly better bone ingrowth compared to the plasma-sprayed control. Additional treatment of the E-beam surface structures with a HA coating, further improved bone ingrowth potential of these structures significantly. Acid etching of the E-beam structures did not influence bone ingrowth significantly. In conclusion, the HA-coated, E-beam-produced structures are promising potential implant surface
    corecore