7 research outputs found
Combining quantitative and qualitative breast density measures to assess breast cancer risk
Abstract Background Accurately identifying women with dense breasts (Breast Imaging Reporting and Data System [BI-RADS] heterogeneously or extremely dense) who are at high breast cancer risk will facilitate discussions of supplemental imaging and primary prevention. We examined the independent contribution of dense breast volume and BI-RADS breast density to predict invasive breast cancer and whether dense breast volume combined with Breast Cancer Surveillance Consortium (BCSC) risk model factors (age, race/ethnicity, family history of breast cancer, history of breast biopsy, and BI-RADS breast density) improves identifying women with dense breasts at high breast cancer risk. Methods We conducted a case-control study of 1720 women with invasive cancer and 3686 control subjects. We calculated ORs and 95% CIs for the effect of BI-RADS breast density and Volpara™ automated dense breast volume on invasive cancer risk, adjusting for other BCSC risk model factors plus body mass index (BMI), and we compared C-statistics between models. We calculated BCSC 5-year breast cancer risk, incorporating the adjusted ORs associated with dense breast volume. Results Compared with women with BI-RADS scattered fibroglandular densities and second-quartile dense breast volume, women with BI-RADS extremely dense breasts and third- or fourth-quartile dense breast volume (75% of women with extremely dense breasts) had high breast cancer risk (OR 2.87, 95% CI 1.84–4.47, and OR 2.56, 95% CI 1.87–3.52, respectively), whereas women with extremely dense breasts and first- or second-quartile dense breast volume were not at significantly increased breast cancer risk (OR 1.53, 95% CI 0.75–3.09, and OR 1.50, 95% CI 0.82–2.73, respectively). Adding continuous dense breast volume to a model with BCSC risk model factors and BMI increased discriminatory accuracy compared with a model with only BCSC risk model factors (C-statistic 0.639, 95% CI 0.623–0.654, vs. C-statistic 0.614, 95% CI 0.598–0.630, respectively; P < 0.001). Women with dense breasts and fourth-quartile dense breast volume had a BCSC 5-year risk of 2.5%, whereas women with dense breasts and first-quartile dense breast volume had a 5-year risk ≤ 1.8%. Conclusions Risk models with automated dense breast volume combined with BI-RADS breast density may better identify women with dense breasts at high breast cancer risk than risk models with either measure alone
Automated and Clinical Breast Imaging Reporting and Data System Density Measures Predict Risk for Screen-Detected and Interval Cancers
BackgroundIn 30 states, women who have had screening mammography are informed of their breast density on the basis of Breast Imaging Reporting and Data System (BI-RADS) density categories estimated subjectively by radiologists. Variation in these clinical categories across and within radiologists has led to discussion about whether automated BI-RADS density should be reported instead.ObjectiveTo determine whether breast cancer risk and detection are similar for automated and clinical BI-RADS density measures.DesignCase-control.SettingSan Francisco Mammography Registry and Mayo Clinic.Participants1609 women with screen-detected cancer, 351 women with interval invasive cancer, and 4409 matched control participants.MeasurementsAutomated and clinical BI-RADS density assessed on digital mammography at 2 time points from September 2006 to October 2014, interval and screen-detected breast cancer risk, and mammography sensitivity.ResultsOf women whose breast density was categorized by automated BI-RADS more than 6 months to 5 years before diagnosis, those with extremely dense breasts had a 5.65-fold higher interval cancer risk (95% CI, 3.33 to 9.60) and a 1.43-fold higher screen-detected risk (CI, 1.14 to 1.79) than those with scattered fibroglandular densities. Associations of interval and screen-detected cancer with clinical BI-RADS density were similar to those with automated BI-RADS density, regardless of whether density was measured more than 6 months to less than 2 years or 2 to 5 years before diagnosis. Automated and clinical BI-RADS density measures had similar discriminatory accuracy, which was higher for interval than screen-detected cancer (c-statistics: 0.70 vs. 0.62 [P < 0.001] and 0.72 vs. 0.62 [P < 0.001], respectively). Mammography sensitivity was similar for automated and clinical BI-RADS categories: fatty, 93% versus 92%; scattered fibroglandular densities, 90% versus 90%; heterogeneously dense, 82% versus 78%; and extremely dense, 63% versus 64%, respectively.LimitationNeither automated nor clinical BI-RADS density was assessed on tomosynthesis, an emerging breast screening method.ConclusionAutomated and clinical BI-RADS density similarly predict interval and screen-detected cancer risk, suggesting that either measure may be used to inform women of their breast density.Primary funding sourceNational Cancer Institute
Recommended from our members
Automated and Clinical Breast Imaging Reporting and Data System Density Measures Predict Risk for Screen-Detected and Interval Cancers: A Case-Control Study.
Background:In 30 states, women who have had screening mammography are informed of their breast density on the basis of Breast Imaging Reporting and Data System (BI-RADS) density categories estimated subjectively by radiologists. Variation in these clinical categories across and within radiologists has led to discussion about whether automated BI-RADS density should be reported instead. Objective:To determine whether breast cancer risk and detection are similar for automated and clinical BI-RADS density measures. Design:Case-control. Setting:San Francisco Mammography Registry and Mayo Clinic. Participants:1609 women with screen-detected cancer, 351 women with interval invasive cancer, and 4409 matched control participants. Measurements:Automated and clinical BI-RADS density assessed on digital mammography at 2 time points from September 2006 to October 2014, interval and screen-detected breast cancer risk, and mammography sensitivity. Results:Of women whose breast density was categorized by automated BI-RADS more than 6 months to 5 years before diagnosis, those with extremely dense breasts had a 5.65-fold higher interval cancer risk (95% CI, 3.33 to 9.60) and a 1.43-fold higher screen-detected risk (CI, 1.14 to 1.79) than those with scattered fibroglandular densities. Associations of interval and screen-detected cancer with clinical BI-RADS density were similar to those with automated BI-RADS density, regardless of whether density was measured more than 6 months to less than 2 years or 2 to 5 years before diagnosis. Automated and clinical BI-RADS density measures had similar discriminatory accuracy, which was higher for interval than screen-detected cancer (c-statistics: 0.70 vs. 0.62 [P < 0.001] and 0.72 vs. 0.62 [P < 0.001], respectively). Mammography sensitivity was similar for automated and clinical BI-RADS categories: fatty, 93% versus 92%; scattered fibroglandular densities, 90% versus 90%; heterogeneously dense, 82% versus 78%; and extremely dense, 63% versus 64%, respectively. Limitation:Neither automated nor clinical BI-RADS density was assessed on tomosynthesis, an emerging breast screening method. Conclusion:Automated and clinical BI-RADS density similarly predict interval and screen-detected cancer risk, suggesting that either measure may be used to inform women of their breast density. Primary Funding Source:National Cancer Institute
Recommended from our members
Mammographic texture and risk of breast cancer by tumor type and estrogen receptor status
Background: Several studies have shown that mammographic texture features are associated with breast cancer risk independent of the contribution of breast density. Thus, texture features may provide novel information for risk stratification. We examined the association of a set of established texture features with breast cancer risk by tumor type and estrogen receptor (ER) status, accounting for breast density. Methods: This study combines five case–control studies including 1171 breast cancer cases and 1659 controls matched for age, date of mammogram, and study. Mammographic breast density and 46 breast texture features, including first- and second-order features, Fourier transform, and fractal dimension analysis, were evaluated from digitized film-screen mammograms. Logistic regression models evaluated each normalized feature with breast cancer after adjustment for age, body mass index, first-degree family history, percent density, and study. Results: Of the mammographic features analyzed, fractal dimension and second-order statistics features were significantly associated (p < 0.05) with breast cancer. Fractal dimensions for the thresholds equal to 10% and 15% (FD_TH10 and FD_TH15) were associated with an increased risk of breast cancer while thresholds from 60% to 85% (FD_TH60 to FD_TH85) were associated with a decreased risk. Increasing the FD_TH75 and Energy feature values were associated with a decreased risk of breast cancer while increasing Entropy was associated with a decreased risk of breast cancer. For example, 1 standard deviation increase of FD_TH75 was associated with a 13% reduced risk of breast cancer (odds ratio = 0.87, 95% confidence interval 0.79–0.95). Overall, the direction of associations between features and ductal carcinoma in situ (DCIS) and invasive cancer, and estrogen receptor positive and negative cancer were similar. Conclusion: Mammographic features derived from film-screen mammograms are associated with breast cancer risk independent of percent mammographic density. Some texture features also demonstrated associations for specific tumor types. For future work, we plan to assess risk prediction combining mammographic density and features assessed on digital images. Electronic supplementary material The online version of this article (doi:10.1186/s13058-016-0778-1) contains supplementary material, which is available to authorized users
Recommended from our members
Automated volumetric breast density measures: differential change between breasts in women with and without breast cancer.
BackgroundGiven that breast cancer and normal dense fibroglandular tissue have similar radiographic attenuation, we examine whether automated volumetric density measures identify a differential change between breasts in women with cancer and compare to healthy controls.MethodsEligible cases (n = 1160) had unilateral invasive breast cancer and bilateral full-field digital mammograms (FFDMs) at two time points: within 2 months and 1-5 years before diagnosis. Controls (n = 2360) were matched to cases on age and date of FFDMs. Dense volume (DV) and volumetric percent density (VPD) for each breast were assessed using Volpara™. Differences in DV and VPD between mammograms (median 3 years apart) were calculated per breast separately for cases and controls and their difference evaluated by using the Wilcoxon signed-rank test. To simulate clinical practice where cancer laterality is unknown, we examined whether the absolute difference between breasts can discriminate cases from controls using area under the ROC curve (AUC) analysis, adjusting for age, BMI, and time.ResultsAmong cases, the VPD and DV between mammograms of the cancerous breast decreased to a lesser degree (- 0.26% and - 2.10 cm3) than the normal breast (- 0.39% and - 2.74 cm3) for a difference of 0.13% (p value < 0.001) and 0.63 cm3 (p = 0.002), respectively. Among controls, the differences between breasts were nearly identical for VPD (- 0.02 [p = 0.92]) and DV (0.05 [p = 0.77]). The AUC for discriminating cases from controls using absolute difference between breasts was 0.54 (95% CI 0.52, 0.56) for VPD and 0.56 (95% CI, 0.54, 0.58) for DV.ConclusionThere is a small relative increase in volumetric density measures over time in the breast with cancer which is not found in the normal breast. However, the magnitude of this difference is small, and this measure alone does not appear to be a good discriminator between women with and without breast cancer