4,905 research outputs found

    Exact O(g^2 alpha_s) top decay width from general massive two-loop integrals

    Full text link
    We calculate the b-dependent self-energy of the top quark at O(g^2 \alpha_s) by using a general massive two-loop algorithm proposed in a previous article. From this we derive by unitarity the O(\alpha_s) radiative corrections to the decay width of the top quark, where all effects associated with the bb quark mass are included without resorting to a mass expansion. Our results agree with the analytical results available for the O(\alpha_s) correction to the top quark width

    Development of a Consensus Statement for the Definition, Diagnosis, and Treatment of Acute Exacerbations of Idiopathic Pulmonary Fibrosis Using the Delphi Technique.

    Get PDF
    © 2015, The Author(s).Introduction: There is a lack of agreed and established guidelines for the treatment of acute exacerbations of idiopathic pulmonary fibrosis (AE-IPF). This reflects, in part, the limited evidence-base underpinning the management of AE-IPF. In the absence of high-quality evidence, the aim of this research was to develop a clinician-led consensus statement for the definition, diagnosis and treatment of AE-IPF. Methods: A literature review was conducted to obtain published material on the definition and treatment of AE-IPF. The results of this review were circulated to an online panel of clinicians for review. Statements were then shared with ten expert respiratory clinicians who regularly treat patients with IPF. A Delphi technique was then used to develop a consensus statement for the definition, diagnosis and treatment of AE-IPF. During the first round of review, clinicians rated the clarity of each statement, the extent to which the statement should be included and provided comments. In two subsequent rounds of review, clinicians were provided with the group median inclusion rating for each statement, and any revised wording of statements to aid clarity. Clinicians were asked to repeat the clarity and inclusion ratings for the revised statements. Results: The literature review, online panel discussion, and face-to-face meeting generated 65 statements covering the definition, diagnosis, and management of AE-IPF. Following three rounds of blind review, 90% of clinicians agreed 39 final statements. These final statements included a definition of AE-IPF, approach to diagnosis, and treatment options, specifically: supportive measures, use of anti-microbials, immunosuppressants, anti-coagulants, anti-fibrotic therapy, escalation, transplant management, and long-term management including discharge planning. Conclusion: This clinician-led consensus statement establishes the ‘best practice’ for the management and treatment of AE-IPF based on current knowledge, evidence, and available treatments. Funding: Boehringer Ingelheim Ltd., Bracknell, West Berkshire, UK

    Red flags presented in current low back pain guidelines: a review.

    Full text link
    OBJECTIVE: The purpose of this study was to identify and descriptively compare the red flags endorsed in guidelines for the detection of serious pathology in patients presenting with low back pain to primary care. METHOD: We searched databases, the World Wide Web and contacted experts aiming to find the multidisciplinary clinical guideline in low back pain in primary care, and selected the most recent one per country. We extracted data on the number and type of red flags for identifying patients with higher likelihood of serious pathology. Furthermore, we extracted data on whether or not accuracy data (sensitivity/specificity, predictive values, etc.) were presented to support the endorsement of specific red flags. RESULTS: We found 21 discrete guidelines all published between 2000 and 2015. One guideline could not be retrieved and after selecting one guideline per country we included 16 guidelines in our analysis from 15 different countries and one for Europe as a whole. All guidelines focused on the management of patients with low back pain in a primary care or multidisciplinary care setting. Five guidelines presented red flags in general, i.e., not related to any specific disease. Overall, we found 46 discrete red flags related to the four main categories of serious pathology: malignancy, fracture, cauda equina syndrome and infection. The majority of guidelines presented two red flags for fracture ('major or significant trauma' and 'use of steroids or immunosuppressors') and two for malignancy ('history of cancer' and 'unintentional weight loss'). Most often pain at night or at rest was also considered as a red flag for various underlying pathologies. Eight guidelines based their choice of red flags on consensus or previous guidelines; five did not provide any reference to support the choice of red flags, three guidelines presented a reference in general, and data on diagnostic accuracy was rarely provided. CONCLUSION: A wide variety of red flags was presented in guidelines for low back pain, with a lack of consensus between guidelines for which red flags to endorse. Evidence for the accuracy of recommended red flags was lacking

    Skip the Alignment: Degenerate, Multiplex Primer and Probe Design Using K-mer Matching Instead of Alignments

    Get PDF
    PriMux is a new software package for selecting multiplex compatible, degenerate primers and probes to detect diverse targets such as viruses. It requires no multiple sequence alignment, instead applying k-mer algorithms, hence it scales well for large target sets and saves user effort from curating sequences into alignable groups. PriMux has the capability to predict degenerate primers as well as probes suitable for TaqMan or other primer/probe triplet assay formats, or simply probes for microarray or other single-oligo assay formats. PriMux employs suffix array methods for efficient calculations on oligos 10-∼100 nt in length. TaqMan® primers and probes for each segment of Rift Valley fever virus were designed using PriMux, and lab testing comparing signatures designed using PriMux versus those designed using traditional methods demonstrated equivalent or better sensitivity for the PriMux-designed signatures compared to traditional signatures. In addition, we used PriMux to design TaqMan® primers and probes for unalignable or poorly alignable groups of targets: that is, all segments of Rift Valley fever virus analyzed as a single target set of 198 sequences, or all 2863 Dengue virus genomes for all four serotypes available at the time of our analysis. The PriMux software is available as open source from http://sourceforge.net/projects/PriMux

    Submarine landslides in the Santa Barbara Channel as potential tsunami sources

    Get PDF
    International audienceRecent investigations using the Monterey Bay Aquarium Research Institutes (MBARI) Remotely Operated Vehicles (ROVs) "Ventana" and "Tiburon" and interpretation of MBARI's EM 300 30 kHz multibeam bathymetric data show that the northern flank of the Santa Barbara Basin has experienced massive slope failures. Of particular concern is the large (130 km2) Goleta landslide complex located off Coal Oil Point near the town of Goleta, that measures 14.6-km long extending from a depth of 90 m to nearly 574 m deep and is 10.5 km wide. We estimate that approximately 1.75 km3 has been displaced by this slide during the Holocene. This feature is a complex compound submarine landslide that contains both surfical slump blocks and mud flows in three distinct segments. Each segment is composed of a distinct head scarp, down-dropped head block and a slide debris lobe. The debris lobes exhibit hummocky topography in the central areas that appear to result from compression during down slope movement. The toes of the western and eastern lobes are well defined in the multibeam image, whereas the toe of the central lobe is less distinct. Continuous seismic reflection profiles show that many buried slide debris lobes exist and comparison of the deformed reflectors with ODP Drill Site 149, Hole 893 suggest that at least 200 000 years of failure have occurred in the area (Fisher et al., 2005a). Based on our interpretation of the multibeam bathymetry and seismic reflection profiles we modeled the potential tsunami that may have been produced from one of the three surfical lobes of the Goleta slide. This model shows that a 10 m high wave could have run ashore along the cliffs of the Goleta shoreline. Several other smaller (2 km2 and 4 km2) slides are located on the northern flank of the Santa Barbara Basin, both to the west and east of Goleta slide and on the Conception fan along the western flank of the basin. One slide, named the Gaviota slide, is 3.8 km2, 2.6 km long and 1.7 km wide. A distinct narrow scar extends from near the eastern head wall of this slide for over 2km eastward toward the Goleta slide and may represent either an incipient failure or a remnant of a previous failure. Push cores collected within the main head scar of this slide consisted of hydrogen sulfide bearing mud, possibly suggesting active fluid seepage and a vibra-core penetrated ~50 cm of recent sediment overlying colluvium or landslide debris confirming the age of ~300 years as proposed by Lee et al. (2004). However, no seeps or indications of recent movement were observed during our ROV investigation within this narrow head scar indicating that seafloor in the scar is draped with mud

    Realization of logically labeled effective pure states for bulk quantum computation

    Full text link
    We report the first use of "logical labeling" to perform a quantum computation with a room-temperature bulk system. This method entails the selection of a subsystem which behaves as if it were at zero temperature - except for a decrease in signal strength - conditioned upon the state of the remaining system. No averaging over differently prepared molecules is required. In order to test this concept, we execute a quantum search algorithm in a subspace of two nuclear spins, labeled by a third spin, using solution nuclear magnetic resonance (NMR), and employing a novel choice of reference frame to uncouple nuclei.Comment: PRL 83, 3085 (1999). Small changes made to improve readability and remove ambiguitie

    Testing nonperturbative techniques in the scalar sector of the standard model

    Get PDF
    We discuss the current picture of the standard model's scalar sector at strong coupling. We compare the pattern observed in the scalar sector in perturbation theory up to two-loop with the nonperturbative solution obtained by a next-to-leading order 1/N expansion. In particular, we analyze two resonant Higgs scattering processes, ff -> H -> f'f' and ff -> H -> ZZ, WW. We describe the ingredients of the nonperturbative calculation, such as the tachyonic regularization, the higher order 1/N intermediate renormalization, and the numerical methods for evaluating the graphs. We discuss briefly the perspectives and usefulness of extending these nonperturbative methods to other theories
    • …
    corecore