710 research outputs found

    Classic but unexpected: a case of Jefferson fracture.

    Get PDF
    A man was found lying dead next to a ladder, with only a laceration surrounded by an abrasion visible upon external examination. No skull fractures were palpable. A CT scan and MRI showed a Jefferson fracture of the atlas, associated to a posterior displacement of the skull, a fracture of the dens of the axis, and fractures of the bodies of C5 and C6. Jefferson fractures typically result from a blow to the apex of the skull. In such cases, forensic pathologists should suspect the existence of a Jefferson fracture, particularly when no severe injuries are visible externally

    Algunas consideraciones sobre la moneda colonial hispano-americana

    Get PDF

    Bargmann-Michel-Telegdi equation and one-particle relativistic approach

    Full text link
    A reexamination of the semiclassical approach of the relativistic electron indicates a possible variation of its helicity for electric and magnetic static fields applied along its global motion due to zitterbewegung effects, proportional to the anomalous part of the magnetic moment.Comment: 10 pages, LATEX2E, uses amsb

    Gluon distributions in nucleons and pions at a low resolution scale

    Full text link
    In this paper we study the gluon distribution functions in nucleons and pions at a low resolution Q2Q^2 scale. This is an important issue since parton densities at low Q2Q^2 have always been taken as an external input which is adjusted through DGLAP evolution to fit the experimental data at higher scales. Here, in the framework of a model recently developed, it is shown that the hypothetical cloud of {\it neutral} pions surrounding nucleons and pions appears to be responsible for the characteristic valence-like gluon distributions needed at the inital low scale. As an additional result, we get the remarkable prediction that neutral and charged pions have different intrinsic sea flavor contents.Comment: final version to appear in Phys. Rev. D. Discussion on several points enlarge

    Low Q2Q^2 wave-functions of pions and kaons and their parton distribution functions

    Get PDF
    We study the low Q2Q^2 wave-functions of pions and kaons as an expansion in terms of hadron-like Fock state fluctuations. In this formalism, pion and kaon wave-functions are related one another. Consequently, the knowledge of the pion structure allows the determination of parton distributions in kaons. In addition, we show that the intrinsic (low Q2Q^2) sea of pions and kaons are different due to their different valence quark structure. Finally, we analize the feasibility of a method to extract kaon's parton distribution functions within this approach and compare with available experimental data.Comment: 13 pages, 3 postscript figures include

    Coronary CT angiography for the assessment of atherosclerotic plaque inflammation: postmortem proof of concept with histological validation.

    Get PDF
    To evaluate the diagnostic utility of multiphase postmortem CT angiography (PMCTA) to detect plaque enhancement as a surrogate marker of inflammation, using fatal coronary plaques obtained from autopsies following sudden cardiac death. In this retrospective study, we included 35 cases (12 women, 34%; median [IQR] age, 52 [11] years), with autopsy-proven coronary thrombosis, histological examination, and multiphase PMCTA. Two radiologists blinded towards histological findings assessed PMCTA for plaque enhancement of the culprit lesion in consensus. Two forensic pathologists determined the culprit lesion and assessed histological samples in consensus. Cases with concomitant vasa vasorum density increase and intraplaque and periadventital inflammation were considered positive for plaque inflammation. Finally, we correlated radiology and pathology findings. All 35 cases had histological evidence of atherosclerotic plaque disruption and thrombosis; 30 (85.7%) had plaque inflammation. Plaque enhancement at multiphase PMCTA was reported in 21 (60%) and resulted in a PPV of 95.2% (77.3-99.2%) and an NPV of 28.6% (17-43.9%). Median histological ratings indicated higher intraplaque inflammation (p = .024) and vasa vasorum density (p = .032) in plaques with enhancement. We found no evidence of a difference in adventitial inflammation between CT-negative and CT-positive plaques (p = .211). Plaque enhancement was found in 2/3 of fatal atherothrombotic occlusions at coronary postmortem CT angiography. Furthermore, plaque enhancement correlated with histopathological plaque inflammation and increased vasa vasorum density. Plaque enhancement on multiphase CT angiography could potentially serve as a noninvasive marker of inflammation in high-risk populations. Phenotyping coronary plaque more comprehensively is one of the principal challenges cardiac imaging is facing. Translating our ex vivo findings of CT-based plaque inflammation assessment into clinical studies might help pave the way in defining high-risk plaque better. • Most thrombosed coronary plaques leading to fatality in our series had histological signs of inflammation. • Multiphase postmortem CT angiography can provide a noninvasive interrogation of plaque inflammation through contrast enhancement. • Atherosclerotic plaque enhancement at multiphase postmortem CT angiography correlated with histopathological signs of plaque inflammation and could potentially serve as an imaging biological marker of plaque vulnerability

    Postmortem coronary artery calcium score in cases of myocardial infarction.

    Get PDF
    Sudden cardiac death (SCD) related to atherosclerotic coronary artery disease (ACAD) resulting in myocardial infarction is the most prevalent cause of death in western countries. In clinical practice, coronary artery calcium score (CACS) is considered an independent predictor of coronary events, closely related to atherosclerotic burden and is quantified radiologically by the Agatston score being calculated through computed tomography. Postmortem computed tomography (PMCT) allows the visualization and quantification of coronary calcifications before the autopsy. However, it was reported that some patients who died from severe ACAD had a zero CACS in PMCT. In this study, a retrospective evaluation of CACS in adult's myocardial infarction cases related to ACAD, with available CACS and histological slides of coronary arteries, was performed in order to gain a deeper understanding of coronary calcifications and their role in myocardial infarction cases. The CACS was calculated by using the software Smartscore 4.0 after the radiological examination on a 64-row CT unit using a specific cardiac protocol. Thirty-six cases were identified out of 582 autopsies, recorded during a 2-year study period (29 men, 7 women; age 56.3 ± 11.7). CACS was 0-10 in 5 cases (5 men, 44.8 ± 13.7), 11-100 in 8 cases (6 men, 2 women, 53.1 ± 7.7), 101-400 in 13 cases (11 men, 2 women, 57.4 ± 9.6), and > 400 in 10 cases (9 men, 1 woman, 63.1 ± 11.9). Coronary thrombosis was found in 28 cases, histologically identified as plaque erosions in 6 cases and as plaque ruptures in 22 cases. Statistical analyses showed that CACS increases significantly with age (p-value < 0.05) and does not show significant correlation with gender, body weight, body mass index, and heart weight. CACS was significantly higher in plaque ruptures than in plaque erosions (p-value < 0.01). Zero or low CACS on unenhanced PMCT cannot exclude the presence of myocardial infarction related to ACAD. This paradoxical discrepancy between imaging and autopsy findings can be explained considering the histological aspect of fatal coronary plaques

    Numerical study of polarisation-selective side-illuminated pin photodetectors grown on InP substrate for hybridisation on silicon platform

    Get PDF
    Abstract: A monolithic polarisation-selective side-illuminated pin photodetector is described using the coupling properties of symmetric and asymmetric slab optical waveguides. First, a basic structure is proposed, analysed and optimised by modal analysis, leading to a computed polarisation ratio of 15.7 dB. Then the symmetric waveguide is replaced by a multimode diluted waveguide optimised by a genetic algorithm coupled to a beam propagation method. This significantly improves the performance of the device and particularly the computed polarisation ratio, which reaches 21 dB. This InP-based photodetector is suitable for hybridisation on a silicon platform and is compatible with 10 Gbit/s operation

    Development of a protocol for standardized use of a water-soluble contrast agent with polyethylene glycol in post-mortem CT angiography.

    Get PDF
    Computed tomography angiography (PMCTA) is increasingly used in postmortem cases. Standardized validated protocols permit to compare different PMCTA images and make it more easily to defend a case in court. In addition to the well-known technique by Grabherr et al. (2011) which is using paraffin oil as a carrier substance, water-soluble polyethylene glycol 200 (PEG200) can be used in combination with the contrast agent Accupaque® 300. As to date, there exists no standardized protocol for the use of this contrast agent mixture, the aim of this study was to develop a protocol using it. Between 2012 and 2022, 23 PMCTA with PEG200 and Accupaque®300 were performed at the University Centre of Legal Medicine Lausanne (Switzerland) and the Institute of Forensic Medicine Munich (Germany). The images obtained were evaluated regarding the opacification of the vessels and possible artefacts. The best image quality was obtained with a mixing ratio of 1:15 (Accupaque®300:PEG200) and a perfusion volume of 1000 ml in the arterial, 1400 ml in the venous and 350 ml in the dynamic phase. The infusion rates described by Grabherr et al. were confirmed for the three phases. Overall, the opacification of the vessels was diagnostically sufficient. In 13 cases no opacification of the right coronary artery was observed due to a stratification artefact. By using the PMCTA protocol with PEG200 as a carrier, a good overall image quality can be achieved. This protocol offers the possibility to standardize PMCTA with PEG200
    corecore