2,299 research outputs found

    Pain in traumatic upper limb amputees in Sierra Leone.

    Get PDF
    Data on 40 upper limb amputees (11 bilateral) with regard to stump pain, phantom sensation and phantom pain is presented. All the patients lost their limbs as a result of violent injuries intended to terrorise the population and were assessed 10-48 months after the injury. All amputees reported stump pain in the month prior to interview and ten of the 11 bilateral amputees had bilateral pain. Phantom sensation was common (92.5%), but phantom pain was only present in 32.5% of amputees. Problems in translation and explanation may have influenced the low incidence of phantom pain and high incidence of stump pain. In the bilateral amputees phantom sensation, phantom pain and telescoping all showed bilateral concordance, whereas stump pain and neuromas did not show concordance. About half the subjects (56%) had lost their limb at the time of injury (primary) while the remainder had an injury, then a subsequent amputation in hospital (secondary). There was no association between the incidence of phantom pain and amputation irrespective of being primary or secondary

    TRA-957: LONDON ON BIKES – LONDON’S CYCLING MASTER PLAN STRATEGIC CHANGES TO IMPROVE LONDON’S CYCLING CULTURE & INFRASTRUCTURE

    Get PDF
    The City of London, Canada has been implementing cycling infrastructure since the 1980s. The City’s formal cycling master planning efforts to improve the cycling culture within the City were successfully “launched” in 2005 with the development and adoption of the City’s first Cycling Master Plan. The first master plan was followed by a strategic implementation plan which was completed in 2007 and used to guide planning, design and engineering efforts by City staff. The completion and adoption of both of these plans has led to the development of comprehensive off-road network of cycling facilities along the City’s premier Thames River Valley and an initial on-road network

    Hyperglycaemia does not increase perfusion deficits after focal cerebral ischaemia in male Wistar rats

    Get PDF
    Background: Hyperglycaemia is associated with a worse outcome in acute ischaemic stroke patients; yet the pathophysiological mechanisms of hyperglycaemia-induced damage are poorly understood. We hypothesised that hyperglycaemia at the time of stroke onset exacerbates ischaemic brain damage by increasing the severity of the blood flow deficit. Methods: Adult, male Wistar rats were randomly assigned to receive vehicle or glucose solutions prior to permanent middle cerebral artery occlusion. Cerebral blood flow was assessed semi-quantitatively either 1 h after middle cerebral artery occlusion using 99mTc-D, L-hexamethylpropyleneamine oxime (99mTc-HMPAO) autoradiography or, in a separate study, using quantitative pseudo-continuous arterial spin labelling for 4 h after middle cerebral artery occlusion. Diffusion weighted imaging was performed alongside pseudo-continuous arterial spin labelling and acute lesion volumes calculated from apparent diffusion coefficient maps. Infarct volume was measured at 24 h using rapid acquisition with refocused echoes T2-weighted magnetic resonance imaging. Results: Glucose administration had no effect on the severity of ischaemia when assessed by either 99mTc-HMPAO autoradiography or pseudo-continuous arterial spin labelling perfusion imaging. In comparison to the vehicle group, apparent diffusion coefficient–derived lesion volume 2–4 h post-middle cerebral artery occlusion and infarct volume 24 h post-middle cerebral artery occlusion were significantly greater in the glucose group. Conclusions: Hyperglycaemia increased acute lesion and infarct volumes but there was no evidence that the acute blood flow deficit was exacerbated. The data reinforce the conclusion that the detrimental effects of hyperglycaemia are rapid, and that treatment of post-stroke hyperglycaemia in the acute period is essential but the mechanisms of hyperglycaemia-induced harm remain unclear

    Using a hypothetical scenario to assess public preferences for colorectal surveillance following screening-detected, intermediate-risk adenomas: annual home-based stool test vs. triennial colonoscopy

    Get PDF
    Background To assess public preferences for colorectal cancer (CRC) surveillance tests for intermediate-risk adenomas, using a hypothetical scenario. Methods Adults aged 45–54 years without CRC were identified from three General Practices in England (two in Cumbria, one in London). A postal survey was carried out during a separate study on preferences for different first-line CRC screening modalities (non- or full-laxative computed tomographic colonography, flexible sigmoidoscopy, or colonoscopy). Individuals were allocated at random to receive a pack containing information on one first-line test, and a paragraph describing CRC surveillance recommendations for people who are diagnosed with intermediate-risk adenomas during screening. All participants received a description of two surveillance options: annual single-sample, home-based stool testing (consistent with Faecal Immunochemical Tests; FIT) or triennial colonoscopy. Invitees were asked to imagine they had been diagnosed with intermediate-risk adenomas, and then complete a questionnaire on their surveillance preferences. Results 22.1 % (686/3,100) questionnaires were returned. 491 (15.8 %) were eligible for analysis. The majority of participants stated a surveillance preference for the stool test over colonoscopy (60.8 % vs 31.0 %; no preference: 8.1 %; no surveillance: 0.2 %). Women were more likely to prefer the stool test than men (66.7 % vs. 53.6 %; p = .011). The primary reason for preferring the stool test was that it would be done more frequently. The main reason to prefer colonoscopy was its superiority at finding polyps. Conclusions A majority of participants stated a preference for a surveillance test resembling FIT over colonoscopy. Future research should test whether this translates to greater adherence in a real surveillance setting

    Stroke penumbra defined by an MRI-based oxygen challenge technique: 2. Validation based on the consequences of reperfusion

    Get PDF
    Magnetic resonance imaging (MRI) with oxygen challenge (T2* OC) uses oxygen as a metabolic biotracer to define penumbral tissue based on CMRO2 and oxygen extraction fraction. Penumbra displays a greater T2* signal change during OC than surrounding tissue. Since timely restoration of cerebral blood flow (CBF) should salvage penumbra, T2* OC was tested by examining the consequences of reperfusion on T2* OC-defined penumbra. Transient ischemia (109±20 minutes) was induced in male Sprague-Dawley rats (n=8). Penumbra was identified on T2*-weighted MRI during OC. Ischemia and ischemic injury were identified on CBF and apparent diffusion coefficient maps, respectively. Reperfusion was induced and scans repeated. T2 for final infarct and T2* OC were run on day 7. T2* signal increase to OC was 3.4% in contralateral cortex and caudate nucleus and was unaffected by reperfusion. In OC-defined penumbra, T2* signal increased by 8.4%±4.1% during ischemia and returned to 3.25%±0.8% following reperfusion. Ischemic core T2* signal increase was 0.39%±0.47% during ischemia and 0.84%±1.8% on reperfusion. Penumbral CBF increased from 41.94±13 to 116.5±25 mL per 100 g per minute on reperfusion. On day 7, OC-defined penumbra gave a normal OC response and was located outside the infarct. T2* OC-defined penumbra recovered when CBF was restored, providing further validation of the utility of T2* OC for acute stroke management

    Stroke penumbra defined by an MRI-based oxygen challenge technique: 1. validation using [14C]2-deoxyglucose autoradiography

    Get PDF
    Accurate identification of ischemic penumbra will improve stroke patient selection for reperfusion therapies and clinical trials. Current magnetic resonance imaging (MRI) techniques have limitations and lack validation. Oxygen challenge T2* MRI (T2* OC) uses oxygen as a biotracer to detect tissue metabolism, with penumbra displaying the greatest T2* signal change during OC. [14C]2-deoxyglucose (2-DG) autoradiography was combined with T2* OC to determine metabolic status of T2*-defined penumbra. Permanent middle cerebral artery occlusion was induced in anesthetized male Sprague-Dawley rats (n=6). Ischemic injury and perfusion deficit were determined by diffusion- and perfusion-weighted imaging, respectively. At 147±32 minutes after stroke, T2* signal change was measured during a 5-minute 100% OC, immediately followed by 125 μCi/kg 2-DG, intravenously. Magnetic resonance images were coregistered with the corresponding autoradiograms. Regions of interest were located within ischemic core, T2*-defined penumbra, equivalent contralateral structures, and a region of hyperglycolysis. A T2* signal increase of 9.22%±3.9% (mean±s.d.) was recorded in presumed penumbra, which displayed local cerebral glucose utilization values equivalent to contralateral cortex. T2* signal change was negligible in ischemic core, 3.2%±0.78% in contralateral regions, and 1.41%±0.62% in hyperglycolytic tissue, located outside OC-defined penumbra and within the diffusion abnormality. The results support the utility of OC-MRI to detect viable penumbral tissue follow

    Structural insights into RNA processing by the human RISC-loading complex.

    Get PDF
    Targeted gene silencing by RNA interference (RNAi) requires loading of a short guide RNA (small interfering RNA (siRNA) or microRNA (miRNA)) onto an Argonaute protein to form the functional center of an RNA-induced silencing complex (RISC). In humans, Argonaute2 (AGO2) assembles with the guide RNA-generating enzyme Dicer and the RNA-binding protein TRBP to form a RISC-loading complex (RLC), which is necessary for efficient transfer of nascent siRNAs and miRNAs from Dicer to AGO2. Here, using single-particle EM analysis, we show that human Dicer has an L-shaped structure. The RLC Dicer's N-terminal DExH/D domain, located in a short 'base branch', interacts with TRBP, whereas its C-terminal catalytic domains in the main body are proximal to AGO2. A model generated by docking the available atomic structures of Dicer and Argonaute homologs into the RLC reconstruction suggests a mechanism for siRNA transfer from Dicer to AGO2

    Clinical ethics revisited: responses

    Get PDF
    This series of responses was commissioned to accompany the article by Singer et al, which can be found at . If you would like to comment on the article by Singer et al or any of the responses, please email us on [email protected]

    Ethyl 4-hydroxy­methyl-2-methyl­pyridine-5-carboxyl­ate

    Get PDF
    The title compound, C10H13NO3, was obtained as a by-product of the aldolization reaction of furo[3,4-c]pyridin-3(1H)-one with thio­phene-2-carboxaldehyde. The substituents on the pyridine ring are nearly coplanar, with an 8.1 (2)° rotation of the hydroxmethyl group from this plane. The mol­ecules assemble in the crystal structure as chains via O—H⋯N hydrogen bonding between the pyridine N atom and a neighbouring hydroxy­methyl OH group

    Damage avoidance design steel beam-column moment connection using high-force-to-volume dissipators

    Get PDF
    Existing welded steel moment frames are designed to tolerate substantial yielding and plastic rotation under earthquake loads. This sacrificial design approach can lead to permanent, and often irreparable damage when interstory drifts exceed 2%. The experimental seismic performance of a 50% full-scale damage avoidance designed structural steel beam-column connection is presented. The beam-column joint region consists of a top flange-hung beam connected to the column by an angle bracket. High-force-to-volume (HF2V) devices are attached from the column to the beam to provide joint rigidity and energy dissipation as the joint opens and closes. The HF2V devices are connected either below the beam flange or concealed above the beam's lower flange. Reversed cyclic lateral load tests are conducted with drift amplitudes up to 4%. No damage is observed in the principal beam and column structural elements. The need for stiff device connections to achieve optimal device performance is demonstrated, and potential design solutions presented. Stable hysteresis and repeatable energy dissipation for a large number of cycles up to the 4% drift level is observed. It is concluded that superior and repeatable energy dissipation without damage can be achieved for every dynamic motion cycle, in contrast to conventional sacrificially designed welded moment frame connections
    corecore