4,488 research outputs found

    Laser interferometric measurement of ion electrode shape and charge exchange erosion

    Get PDF
    A projected fringe profilometry system was applied to surface contour measurements of an accelerator electrode from an ion thrustor. The system permitted noncontact, nondestructive evaluation of the fine and gross structure of the electrode. A 3-D surface map of a dished electrode was generated without altering the electrode surface. The same system was used to examine charge exchange erosion pits near the periphery of the electrode to determine the depth, location, and volume of material lost. This electro-optical measurement system allowed rapid, nondestructive, digital data acquisition coupled with automated computer data processing. In addition, variable sensitivity allowed both coarse and fine measurements of objects having various surface finishes

    Requirements for long-life operation of inert gas hollow cathodes: Preliminary report

    Get PDF
    An experimental investigation was initiated to establish conditioning procedures for reliable hollow cathode operation via the characterization of critical parameters in a representative cathode test facility. From vacuum pumpdown rates, it was found that approximately 1.5 hours were required to achieve pressure levels within 5 percent of the lowest attainable pressure for this facility, depending on the purge conditions. The facility atmosphere was determined by a residual gas analyzer to be composed of primarily air and water vapor. The effects of vacuum pumping and inert gas purging were evaluated. A maximum effective leakage rate of 2.0 x 10(exp -3)sccm was observed and its probable causes were examined. An extended test of a 0.64 cm diameter Mo-Re hollow cathode was successfully completed. This test ran for 504 hours at an emission current of 23.0 amperes and a xenon flow rate of 6.1 sccm. Discharge voltage rose continuously from 15 to 21 volts over the course of the test. The temperature of the cathode body during the test was relatively stable at 1160 C. Post-test examination revealed ion-bombardment texturing of the orifice plate to be the only detectable sign of wear on the hollow cathode

    Preliminary endurance tests of water vaporizers for resistojet applications

    Get PDF
    Three water vaporizers designed for resistojet applications were built and tested for periods up to 500 h and 250 thermal cycles. Two of the vaporizers were not sensitive to orientation with respect to gravity, an indication of likely compatibility with low-gravity environments. Some temperatures and pressures in the third were impacted by orientation, although operation was always stable. The pressure drop across the sand-filled version increased by 147 percent in 38 h and 19 thermal cycles. Bonding of the sand granules in the downstream end of the heat exchanger was the suspected cause of failure of this vaporizer. Pressure drops across the two sintered stainless steel-filled versions were more gradual. One, with a pore size of 60 microns, showed an 80 percent increase in 500 h and 250 thermal cycles and another, with a 10 microns poresize, showed a 29 percent increase in 350 h and 175 thermal cycles. Testing of the latter metal-filled vaporizer was ongoing as of this writing. Oxidation of the porous metal packing materials in these vaporizers, with subsequent deposition of oxide particles within the pores, was believed to have caused the observed increases in pressure drops

    Reliability of measuring thoracic kyphosis angle, lumbar lordosis angle and straight leg raise with an inclinometer

    Get PDF
    Licensed under the terms of the Creative Commons Attribution non-commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted, non-commercial use, distribution and reproduction in any medium, providing that the work is properly citedPurpose: Several non-invasive measurement methods have been described in the literature for recording thoracic kyphosis, lumbar lordosis and straight leg raise (SLR). However, attempts to quantify the reliability of the inclinometer in these measurements are scarce. In addition, existing reliability studies within the literature were found to use small sample sizes. The aim of this investigation was to examine the intra-rater reliability of the chief investigator (SM), in order to provide clinicians with data that will allow them to better measure sagittal spinal posture and SLR. A blinded test-retest design was performed to determine the intra-rater reliability of thoracic kyphosis, lumbar lordosis and SLR when assessed using an Isomed inclinometer in normals. Methods. Thirty asymptomatic subjects were assessed on two occasions separated by a time interval of 1 hour to reduce investigator memory bias. Thoracic and lumbar measurements were recorded in a relaxed standing position using an inclinometer; SLR of the dominant leg was assessed with subjects in the supine position. Intraclass correlation coefficients (ICC), 95% confidence intervals (CI), and standard errors of measurement (SEM) were analysed to determine measurement reliability. Results. The chief investigator demonstrated excellent intra-rater reliability in the measurements of thoracic kyphosis, lumbar lordosis and SLR. ICC (2,3) values for all three variables exceeded the 0.90 threshold suggesting that the reliability of these measures are acceptable for clinical application. Conclusions. The inclinometer technique employed in this study to record thoracic kyphosis, lumbar lordosis and SLR is a reliable measurement method.Peer reviewe

    Structural and thermal response of 30 cm diameter ion thruster optics

    Get PDF
    Tabular and graphical data are presented which are intended for use in calibrating and validating structural and thermal models of ion thruster optics. A 30 cm diameter, two electrode, mercury ion thruster was operated using two different electrode assembly designs. With no beam extraction, the transient and steady state temperature profiles and center electrode gaps were measured for three discharge powers. The data showed that the electrode mount design had little effect on the temperatures, but significantly impacted the motion of the electrode center. Equilibrium electrode gaps increased with one design and decreased with the other. Equilibrium displacements in excess of 0.5 mm and gap changes of 0.08 mm were measured at 450 W discharge power. Variations in equilibrium gaps were also found among assemblies of the same design. The presented data illustrate the necessity for high fidelity ion optics models and development of experimental techniques to allow their validation

    Import licensing in Kenya

    Get PDF
    This paper gives an account of how the import licensing system in Kenya has developed up to and including the introduction of foreign exchange allocation licensing in December, 1972. This means by which different categories of imports are treated by the authorities are outlined and the theoretical implications of import restrictions discussed. It is postulated that import licensing is the major means of protecting local manufacturers in Kenya. So the appendix tables indicate the import licensing system has evolved to cover a large proportion of imparts entering Kenya. The paper is primarily descriptive and contains no results of empirical work related to this topic

    Introducing national healthcare safety investigation bodies

    Get PDF

    Inhibition of cell proliferation rather than of cell lysis as a measure of immune reactivity in embryo-antigen-challenged mice.

    Get PDF
    An assay system is described in which effector cells added along with suitable target cells inhibit, in a quantitative fashion, the subsequent uptake of 3H-thymidine by those target cells. Effector cells active in this assay, using embryonic fibroblast cells as targets, develop spontaneously in cultures of mouse lymphoid cells, but are apparently different from those described earlier by investigators of activity in cytotoxic assays. Further evidence is presented to show the development of spleen-derived effector cells with cytostatic activity (for embryonic fibroblast target cells) in mice during the course of normal pregnancy, or growth of spontaneously appearing mammary adenocarcinomas. Indeed, such effector cells can also be found within the growing solid mass itself. Different populations of tumour cells isolated from a solid tumour apparently differ in their susceptibility to growth inhibition by tumour-bearer-derived cytostatic effector cells, a phenomenon which may be related to metastatic spread of tumour cells

    Tumour-cell susceptibility to cytotoxic or cytostatic effector cells in vitro and the regulation of tumour-cell growth in vivo.

    Get PDF
    Tumour-cell growth in lung nodules after i.v. transfer to sublethally irradiated mice has been followed after adoptive transfer of different populations of lymphoid cells. Spleen cells deliberately immunized in vitro and in vivo against stimulator cells bearing embryo-associated antigens and which are cytostatic in vitro for targets bearing such antigens, can diminish the number of lung nodules found after i.v. transfer. In contrast, cytotoxic (in vitro) spleen cells, while capable of diminishing local (s.c.) growth of tumour cells, cannot control systemic tumour growth. Within a given solid tumour mass, the subpopulations resistant to cytostatic effector cells in vitro are the ones most likely to produce lung colonies after adoptive transfer in vivo, though they show no more local (s.c.) growth than to cytostatic-sensitive cells in vivo
    • …
    corecore