30 research outputs found

    Treatment of displaced intra-articular calcaneal fractures by ligamentotaxis: current concepts’ review

    Get PDF
    Introduction: A large variety of therapeutic modalities for calcaneal fractures have been described in the literature. No single treatment modality for displaced intra-articular calcaneal fractures has proven superior over the other. This review describes and compares the different percutaneous distractional approaches for intra-articular calcaneal fractures. The history, technique, anatomical and fracture considerations, limitations and the results of different distractional approaches reported in the literature are reviewed. Method: Literature review on different percutaneous distractional approaches for displaced intra-articular calcaneal fractures. Results: Eight studies in which application of a distraction technique was used for the treatment of calcaneal fractures were identified. Because of the use of different classification, techniques, and outcome scoring systems, a meta-analysis was not possible. A literature review reveals overall fair to poor result in 10-29% of patients. Ten up to 26% of patients are unable to return to work after percutaneous treatment of their fracture. A secondary arthrodesis has to be performed in 2-15% of the cases. Infectious complications occur in 2-15%. Some loss of reduction is reported in 4-67%. Conclusion: Percutaneous distractional reduction and fixation appears to be a safe technique with overall good results and an acceptable complication rate, compared with other treatment modalities for displaced intra-articular calcaneal fractures. A meta-analysis, based on Cochrane Library criteria is not possible, because of a lack of level 1 and 2 trials on this subject

    Meniscal tear—a feature of osteoarthritis

    Full text link

    A comparison of the biological effective dose of 50-kV electronic brachytherapy with (192)Ir high-dose-rate brachytherapy for vaginal cuff irradiation

    No full text
    PURPOSE: Advantages for electronic brachytherapy (EBT) of the vaginal cuff include decreased physical dose to the bladder and rectum. Here we compare (192)Ir with EBT using biological effective dose (BED) to account for the different radiobiological effectiveness (RBE) predicted for low-energy x-rays. METHODS AND MATERIALS: Fifteen data sets from five consecutive postoperative endometrial cancer patients treated with EBT were analyzed. Treatment planning was performed using PLATO software. The dose was prescribed as 21Gy in three fractions to a depth of 0.5cm. Physical dose, BED(3), and BED(10) were evaluated for the mucosa, bladder, and rectum. An RBE value of 1.5 was used for BED calculations. RESULTS: Mucosal physical dose is 28.4% greater with EBT (36.6 vs. 28.5Gy, p\u3c0.05). However, the BED(10) is increased by 79.1% (55.6 vs. 99.6Gy, p\u3c0.05) and the BED(3) by 71.5% (118.8 vs. 203.7Gy, p\u3c0.05). The physical dose (dose to 50% volume of the organ) to the bladder (9.3 vs. 6.6Gy, p\u3c0.05) and rectum (7.2 vs. 4.2Gy, p\u3c0.05) are reduced with EBT. BED(3) to the rectum and bladder are also reduced but to a lesser extent (13 vs. 8.3Gy, p\u3c0.05; 18.9 vs. 14.7Gy, p=0.06, respectively). CONCLUSIONS: BED takes into account the higher RBE of low-energy photons generated with EBT and provides a more accurate estimate of the biological effect. When using EBT, physical dose may underestimate the biological effect on the vaginal mucosa and overestimate the benefit for the bladder and rectum. Dose adjustment for EBT based on BED should be considered. rights reserved
    corecore