29 research outputs found

    Vanishing spin alignment : experimental indication of triaxial 28Si+28Si\bf ^{28}Si + {^{28}Si} nuclear molecule

    Full text link
    Fragment-fragment-γ\gamma coincidences have been measured for 28Si+28Si\rm ^{28}Si + {^{28}Si} at an energy corresponding to the population of a conjectured resonance in 56^{56}Ni. Fragment angular distributions as well as γ\gamma-ray angular correlations indicate that the spin orientations of the outgoing fragments are perpendicular to the orbital angular momentum. This differs from the 24Mg+24Mg\rm ^{24}Mg+{^{24}Mg} and the 12C+12C\rm ^{12}C+{^{12}C} resonances, and suggests two oblate 28Si\rm ^{28}Si nuclei interacting in an equator-to-equator molecular configuration.Comment: 14 pages standard REVTeX file, 3 ps Figures -- Accepted for publication in Physical Review C (Rapid Communication

    Development and external validation of prediction models to predict implantable cardioverter-defibrillator efficacy in primary prevention of sudden cardiac death

    Get PDF
    Aims This study was performed to develop and externally validate prediction models for appropriate implantable cardioverter-defibrillator (ICD) shock and mortality to identify subgroups with insufficient benefit from ICD implantation.Methods and results We recruited patients scheduled for primary prevention ICD implantation and reduced left ventricular function. Bootstrapping-based Cox proportional hazards and Fine and Gray competing risk models with likely candidate predictors were developed for all-cause mortality and appropriate ICD shock, respectively. Between 2014 and 2018, we included 1441 consecutive patients in the development and 1450 patients in the validation cohort. During a median follow-up of 2.4 (IQR 2.1-2.8) years, 109 (7.6%) patients received appropriate ICD shock and 193 (13.4%) died in the development cohort. During a median follow-up of 2.7 (IQR 2.0-3.4) years, 105 (7.2%) received appropriate ICD shock and 223 (15.4%) died in the validation cohort. Selected predictors of appropriate ICD shock were gender, NSVT, ACE/ARB use, atrial fibrillation history, Aldosterone-antagonist use, Digoxin use, eGFR, (N)OAC use, and peripheral vascular disease. Selected predictors of all-cause mortality were age, diuretic use, sodium, NT-pro-BNP, and ACE/ARB use. C-statistic was 0.61 and 0.60 at respectively internal and external validation for appropriate ICD shock and 0.74 at both internal and external validation for mortality.Conclusion Although this cohort study was specifically designed to develop prediction models, risk stratification still remains challenging and no large group with insufficient benefit of ICD implantation was found. However, the prediction models have some clinical utility as we present several scenarios where ICD implantation might be postponed.Cardiolog

    Magnetic resonance imaging in patients with cardiac implantable electronic devices

    Get PDF
    In recent years the prevalence of implantation of acardiac implantable electronic device (CIED) has increased due to expanding implantation indications and prolonged life expectancy. Diagnostic strategies increasingly employ magnetic resonance imaging (MRI) to aid therapeutic strategies. In earlier guidelines, MRI was contra-indicated in patients with CIEDs, mainly due to previous reports of severe complications. With the development of MRI-conditional CIEDs and recent evidence concerning non-MRI-conditional CIEDs, MRIs in CIED patients can be safely performed in many hospitals.However, there are several questions that need to be addressed. Which patients can we scan? How can the scans be performed safely? And last but not least, can cardiac MRI provide diagnostic yield in patients with CIEDs?Current European guidelines are rather outdated and vague about patient selection and practical issues. There are national guidelines on this topic but several issues need extra attention and those are addressed in this point of view. It is important to create an environment with proper patient selection without unnecessary MRI scans in CIED patients, but also without unnecessary fear of complications, preventing access to MRI in patients who can benefit from this powerful diagnostic tool

    Comparison of the relation of the ESC 2021 and ESC 2013 definitions of left bundle branch block with clinical and echocardiographic outcome in cardiac resynchronization therapy

    No full text
    IntroductionWe aimed to investigate the impact of the 2021 European Society of Cardiology (ESC) guideline changes in left bundle branch block (LBBB) definition on cardiac resynchronization therapy (CRT) patient selection and outcomes. MethodsThe MUG (Maastricht, Utrecht, Groningen) registry, consisting of consecutive patients implanted with a CRT device between 2001 and 2015 was studied. For this study, patients with baseline sinus rhythm and QRS duration >= 130ms were eligible. Patients were classified according to ESC 2013 and 2021 guideline LBBB definitions and QRS duration. Endpoints were heart transplantation, LVAD implantation or mortality (HTx/LVAD/mortality) and echocardiographic response (LVESV reduction >= 15%). ResultsThe analyses included 1.202, typical CRT patients. The ESC 2021 definition resulted in considerably less LBBB diagnoses compared to the 2013 definition (31.6% vs. 80.9%, respectively). Applying the 2013 definition resulted in significant separation of the Kaplan-Meier curves of HTx/LVAD/mortality (p < .0001). A significantly higher echocardiographic response rate was found in the LBBB compared to the non-LBBB group using the 2013 definition. These differences in HTx/LVAD/mortality and echocardiographic response were not found when applying the 2021 definition. ConclusionThe ESC 2021 LBBB definition leads to a considerably lower percentage of patients with baseline LBBB then the ESC 2013 definition. This does not lead to better differentiation of CRT responders, nor does this lead to a stronger association with clinical outcomes after CRT. In fact, stratification according to the 2021 definition is not associated with a difference in clinical or echocardiographic outcome, implying that the guideline changes may negatively influence CRT implantation practice with a weakened recommendation in patients that will benefit from CRT

    Comparison of the relation of the ESC 2021 and ESC 2013 definitions of left bundle branch block with clinical and echocardiographic outcome in cardiac resynchronization therapy.

    No full text
    INTRODUCTION: We aimed to investigate the impact of the 2021 European Society of Cardiology (ESC) guideline changes in left bundle branch block (LBBB) definition on cardiac resynchronization therapy (CRT) patient selection and outcomes. METHODS: The MUG (Maastricht, Utrecht, Groningen) registry, consisting of consecutive patients implanted with a CRT device between 2001 and 2015 was studied. For this study, patients with baseline sinus rhythm and QRS duration ≥ 130ms were eligible. Patients were classified according to ESC 2013 and 2021 guideline LBBB definitions and QRS duration. Endpoints were heart transplantation, LVAD implantation or mortality (HTx/LVAD/mortality) and echocardiographic response (LVESV reduction ≥15%). RESULTS: The analyses included 1.202, typical CRT patients. The ESC 2021 definition resulted in considerably less LBBB diagnoses compared to the 2013 definition (31.6% vs. 80.9%, respectively). Applying the 2013 definition resulted in significant separation of the Kaplan-Meier curves of HTx/LVAD/mortality (p < .0001). A significantly higher echocardiographic response rate was found in the LBBB compared to the non-LBBB group using the 2013 definition. These differences in HTx/LVAD/mortality and echocardiographic response were not found when applying the 2021 definition. CONCLUSION: The ESC 2021 LBBB definition leads to a considerably lower percentage of patients with baseline LBBB then the ESC 2013 definition. This does not lead to better differentiation of CRT responders, nor does this lead to a stronger association with clinical outcomes after CRT. In fact, stratification according to the 2021 definition is not associated with a difference in clinical or echocardiographic outcome, implying that the guideline changes may negatively influence CRT implantation practice with a weakened recommendation in patients that will benefit from CRT

    Implantable defibrillator therapy and mortality in patients with non-ischaemic dilated cardiomyopathy An updated meta-analysis and effect on Dutch clinical practice by the Task Force of the Dutch Society of Cardiology

    No full text
    Background Primary prophylactic implantable cardioverter-defibrillators (ICDs) in patients with non-ischaemic cardiomyopathy (NICMP) remains controversial. This study sought to assess the benefit of ICD therapy with or without cardiac resynchronisation therapy (CRT) in patients with NICMP. In addition, data were compared with real-world clinical data to perform a risk/benefit analysis. Methods Relevant randomised clinical trials (RCTs) published in meta-analyses since DANISH, and in PubMed, EMBASE and Cochrane databases from 2016 to 2020 were identified. The benefit of ICD therapy stratified by CRT use was assessed using random effects meta-analysis techniques. Results Six RCTs were included in the meta-analysis. Among patients without CRT, ICD use was associated with a 24% reduction in mortality (hazard ratio [HR]: 0.76; 95% confidence interval [CI]: 0.62-0.93; P = 0.008). In contrast, among patients with CRT, a CRT-defibrillator was not associated with reduced mortality (HR: 0.74, 95% CI 0.47-1.16; P = 0.19). For ICD therapy without CRT, absolute risk reduction at 3-years follow-up was 3.7% yielding a number needed to treat of 27. Conclusion ICD use significantly improved survival among patients with NICMP who are not eligible for CRT. Considering CRT, the addition of defibrillator therapy was not significantly associated with mortality benefit compared with CRT pacemaker
    corecore