202 research outputs found

    Initial experience with Vanguard(R) total knee arthroplasty

    Get PDF
    Introduction Biomet Vanguard(R) Complete Knee System is a total knee replacement system, introduced into the market in 2003: thissystem boasts a designed kneecap track or groove which allows for greater mobility and decreased loss of healthy bone during the replacement process. Clinical and radiographic results in Varese Orthopaedics Unit initial experience are reported. Materials and methods Clinical and radiographic parameters are evaluated in 29 patients who underwent TKA (Vanguard(R) Complete Knee System- Biomet Inc.) for primary gonarthrosis during the last 2 years at Orthopaedics and Traumatology Unit of Ospedale di Circolo\u2014Fondazione Macchi in Varese. ROM, type of anaesthesia, patellar pain, clinical and functional Knee Score (pre-operative), size of implant, ROM, blooding, patellar pain, VAS, clinical and func- tional Knee Score (post-operative) are analyzed. Radiographic follow-up is made at 6 and 12 months. Results Clinical and Functional Knee Score respectively improve from 47 to 88 pts and from 51 to 88 pts in pre- and post-operative period (p\0.001). Post-operatively no patellar pain, 2 pts VAS and 1215 cc blooding are reported. ROM doesn\u2019t significantly improve from pre- to post-operative. No relevant complications are reported. Due to the short follow-up, radiographic evaluation does not allow to demonstrate polyethylene liner wear. Conclusions Vanguard(R) Knee Replacement significantly shows a clinical and functional improvement in patients affected by primary gonarthrosis. Moreover, post-operative pain decrease allows early mobilization and rehabilitation

    Carpal Tunnel Syndrome Associated with Bifid Median Nerve and Palmaris Profundus - Case Report and Literature Review

    Get PDF
    The anatomic variations of the median nerve and of the muscles of the wrist have been widely reported in literature. It is essential for the surgeon to be familiar with these variations in order to avoid accidental injury to the nerve during surgery. We report a rare case of bifid median nerve accompanied by an anomalous tendon of palmaris profundus discovered during the surgical release of carpal tunnel. The transverse carpal ligament was dissected and the anomalous tendon was left in situ because any direct compression over the median nerve was noticed intraoperatively. The patient was evaluated one year postoperatively clinically and radiologically (with MRI). At the follow up the resolution of symptoms was complete and the sleep disturbance was solved. The patient achieved a postoperative QuickDASH score of 9.1 and a Michigan Hand Questionnaire outcome score of 90 points

    Treatment of periprosthetic femoral fractures with distal fixation modular revision stems

    Get PDF
    Background Late periprosthetic fractures of the femur are the third most frequently reported cause of surgery after total hip artroplasty. Revision total hip artroplasty can be difficult, especially when poor bone stock is encountered. The aim of this study was to examine the results of late periprosthetic fractures complicated with primary implant loosening performed with distal fixation modular revision stem. Methods From November 1999 to May 2006, 16 late periprosthetic fractures were treated with distal-fixation, modular, straight stem. There were 13 females (82%) and 3 males (18%) whose mean age at surgery was 76.7 years (range, 48 to 95 years). Femoral revision surgery was performed with the Revitan (2 cases) and ZMR (14 cases) to get a stable distal primary fixation. X-rays were assessed accordingly to the Vancouver classification: there were 3 type B2 and 13 type B3 fractures. Mean post-operative follow-up was 52 months (range, 10 to 88 months). At the time of the last follow-up visit 4 patients already passed away, all of them for causes unrelated to the procedure. The clinical outcome was monitored with the Harris Hip Score, subjective VAS, pain and satisfaction evaluation. Standard AP and lateral x-rays of the hip were obtained at each follow-up visit. Leg-length discrepancy was also investigated as a factor possibly affecting outcome. Complications included one septic loosening that was treated with a two-stage revision. Results All the patients but one were finally able to walk and had minimal to no pain at all. A satisfactory functional outcome was achieved with an average 76 (range, 25 to 100) Harris Hip Scores points. The subjective pain and satisfaction scores were respectively 2.4 and 7.8 points. As far as radiograms are concerned, all the sixteen femur did show a good healing of the fracture, with no secondary stem subsidence. Discussion Generally, considering the severity of an event such as a periprosthetic late fracture in an elderly patient, results were satisfactory. The average Harris Hip Score and subjective satisfaction would have been even higher if one patient wouldn\u2019t have been so much disappointed because of her severe leg-length discrepancy, dependent on the acetabular side. From a surgical point of view, the employed devices proved to be handy in bridging the fracture with distal fixation while adequately stabilizing it. Conclusions According to the reported results, straight modular-revison stems provide an adequate treatment option of Vancouver type B3 and in selected cases of B2 type periprosthetic femoral fracture

    Femoral revision with the modular ZMR stem. Clinical and x-rays results at medium term follow-up

    Get PDF
    A retrospective review was conducted to evaluate the medium-term results of the ZMR modular revision taper stem. From March 1999 to December 2002, 65 consecutive hip revision surgeries were performed mostly for aseptic loosening. Femoral bone stock defects were classified according to AAOS\u2019s criteria and consisted mainly in type II and type III. A Wagner osteotomy was performed in 25 cases to remove primary implants that were cemented in 35 cases. Mean post-operative follow-up was 69 months (range, 36 to 91months). Clinical assessment at follow-up showed a significantly improved mean Harris Hip Score from 42 points preoperatively to 81 points postoperatively, while the x-ray examination did show a satisfactory distal integration of the stem in all cases and satisfactory reconstitution of the femoral bone stock in 47% of cases. The average subsidence of the stem at follow-up was under one millimeter. According to the data leg length discrepancy exceeding 15 millimeters caused significantly higher functional impairment and more pain

    Lateral parapatellar approach in primary total knee arthroplasty of the valgus knee

    Get PDF
    Background Anatomic and pathological characteristics of the valgus knee deformity represent a challenging issue for the implant of a total knee arthroplasty. The surgical approach in such cases should allow a direct ad easy exposure of the joint, easy lateral soft tissue balancing and adequate patellar tracking. Materials and Methods Twenty-four total knee arthroplasties were implanted in valgus knees between January 2002 and September 2005. A mean preoperative valgus deformity of 18\ub0 was assessed on standing x-rays. Four posterior stabilized, eighteen posterior stabilized rotating platform prosthesis and two superstabilized prosthesis were implanted in 21 patients. The surgical approach has been in all cases a lateral parapatellectomy. Follow-up assessments were obtained for all patients at a mean 23 months. They consisted of a Knee Society Score and a Patellar Score evaluation, standing AP and lateral radiograms and skyline x-rays obtained at a flection of 45\ub0. Results A mean preoperative Knee Society Clinical Score of 32,7 points (range, -4 to 64 points) significantly improved at follow-up to an average 88,8 points (range, 57 to 99 points; p<0,05). The Knee Society Function Score significantly increased from a preoperative mean score of 32,7 points (range, -20 to 75 points) to an average followup score of 81,2 points (range, 30 to 100 points; p<0.05). The Patella Score revealed absence of anterior pain in all cases but one that reported severe pain. A satisfactory patello-femoral alignement of 4.7\ub0 (range, 1\ub0 to 10\ub0) was obtained at last follow-up x-rays. One intraoperative condilar fracture occured and was treated with a single screw. Discussion The lateral approach of valgus knees led to satisfactory results in primary total knee arthroplasties in a percentage of cases comparable or superior to those presented in literature for different approaches. In addition, lateral release is performed as a part of the approach itself, allows preservation of the blood supplies of the extensor apparatus and an optimal patellar tracking in most cases. Conclusions In conclusion, the lateral approach for a primary total knee arthroplasty could be recommended in valgus knees affected by osteoarthritis because as it proved to be effective in achieving a satisfactory implant positioning and functional outcome while reporting minor complications

    Fracture of cobalt-crome modular neck in total hip arthroplasty

    Get PDF
    Despite the advantages of modular total hip arthroplasty in terms of neck version, offset and length precise reproduction, titanium necks breakage became a concern. Consequently, titanium has been replaced by cobalt-chrome (Co-Cr). However, four cases of Co-Cr modular neck breakage have been reported in the literature. In the present paper, two cases of Co-Cr modular neck fractures are described together with a literature review. The aim of this work is to discuss the risk factors and characteristics of this rare complication. We described two cases of fracture of long varus Co-Cr modular femoral neck connected with cementless press-fit stem. Some risk factors, such as long varus type of modular neck, overweight and/or high demanding physical activity, might have contributed to implant failure. (www.actabiomedica.it)

    Radiological evaluation of the metal-bone interface of a porous tantalum acetabular component

    Get PDF
    Introduction Porous tantalum presents a bone-matched elastic modulus and an high coefficient of friction on cancellous and cortical bone. Furthermore, its open-cell tantalum structure of repeating dodecahedrons, similar to cancellous bone, should be favourable for bone ingrowth. These physical and mechanical properties should increase primary fixation and potential osteointegration of acetabular cups and should decrease periacetabular stress shielding. The purpose of this study was to radiographically evaluate the evolution of the metal-bone interface of porous tantalum acetabular components. Materials and Methods Serial radiographic evaluation of 41porous tantalum acetabular component has been performed in 40 patients. Twelve hips underwent total hip arthroplasty using a trabecular metal monoblock acetabular component and 29 hips using a trabecular metal modular acetabular system. All patients were clinically and radiographically evaluated at four, eight, 12, 24 weeks, 12 months and then annually. All cases were available for a minimum follow-up of two years (mean 35 months). On post-operative x-rays the metal-bone interface was investigated for areas in which the porous surface of the acetabular component was not in contact with bone. These gaps were measured and classified by location according to DeLee and Charnley zones. Evolution of postoperative gaps, presence of lysis or periacetabular radiolucencies and component migration were assessed during follow-up. Results On post-operative x-rays 36 components (88%) had a gap between the outer surface and the host bone but only in 12 cases (29%) gaps were larger then 1 mm. The gaps were mostly situated in the polar region (zone II) when compared with the peripheral zones and no one was bigger then 5 mm in width. At last follow-up 23 (64%) of the initial gaps were no longer radiographically evident, 10 (28%) had a favourable evolution and appeared reduced in dimension but still present and 3 (8%) didn\u2019t fill at all and were unchanged when compared with post-operative controls. There was no progression progression of any post-operative gap and no evidence of new periacetabular radiolucent lines or lysis. No acetabular implant showed evidence of migration or needed revision for loosening. At last follow up the mean Harris Hip Score was 95. There were no dislocation or other complications. Discussion Short term results with porous tantalum acetabular component are encouraging: the bridging of the interface gaps and the absence of periacetabular radiolucencies indicate good mechanical and osteoconductive properties. Further follow-up will be required to confirm these results in the long term

    Acetabular revision surgery in the presence of severe bone loss: surgical technique and early results with modular porous tantalum augments and cups

    Get PDF
    Subject: In the presence of minimal acetabular bone loss most revision procedures can be done with the use of an uncemented hemispheric device with or without morselized allograft. The use of modular porous tantalum augments and cups has been recently introduced to address more severe bone deficiencies. The purpose of this study is to describe the surgical technique and early clinical results obtained with trabecular metal acetabular augments in cases of acetabular revision with severe bone loss. Materials and Methods: Since November 2003 seven acetabular revisions have been done by means of TMT\uae augments and cups: the primary indication for acetabular revision was aseptic loosening in five patients and septic loosening in two patients. According to Paprosky classification the acetabular bone defects were classified as follows: 2B in two hips, 2C in one hip, 3A in two hips and 3B in three hips. In two cases it was the first surgical hip replacement procedure. Five cases were multiple revisions. Results: At an average follow-up of 24 months no implant had evidence of loosening or migration. No dislocations occurred. Discussions and Conclusions: Augments provide mechanical support to hemispheric cups of various dimensions. This surgical technique avoids the use of structural allograft, helps to restore the center of hip rotation and increases contact area between the implant and the host bone for biological fixation. Longer follow-up is required to verify survival of these implants and potential mechanical and biologic complications related to use of this modular TMT\uae system

    Treatment of Severe Post-traumatic Bone Defects With Autologous Stem Cells Loaded on Allogeneic Scaffolds.

    Get PDF
    Mesenchymal stem cells may differentiate into angiogenic and osteoprogenitor cells. The effectiveness of autologous pluripotent mesenchymal cells for treating bone defects has not been investigated in humans. We present a case series to evaluate the rationale of using nucleated cells from autologous bone marrow aspirates in the treatment of severe bone defects that failed to respond to traditional treatments. Ten adult patients (mean age, 49.6-years-old) with severe bone defects were included in this study. Lower limb bone defects were &gt;or=5 cm3 in size, and upper limb defects .or=2 cm3. Before surgery, patients were tested for antibodies to common pathogens. Treatment consisted of bone allogeneic scaffold enriched with bone marrow nucleated cells harvested from the iliac crest and concentrated using an FDA-approved device. Postsurgery clinical and radiographic follow-up was performed at 1, 3, 6, and 12 months. To assess viability, morphology, and immunophenotype, bone marrow nucleated cells were cultured in vitro, tested for sterility, and assayed for the possible replication of adventitious (contaminating) viruses. In 9 of 10 patients, both clinical and radiographic healing of the bone defect along with bone graft integration were observed (mean time, 5.6 months); one patient failed to respond. No post-operative complications were observed. Bone marrow nucleated cells were enriched 4.49-fold by a single concentration step, and these enriched cells were free of microbial contamination. The immunophenotype of adherent cells was compatible with that of mesenchymal stem cells. We detected the replication of Epstein-Barr virus in 2/10 bone marrow cell cultures tested. Hepatitis B virus, cytomegalovirus, parvovirus B19, and endogenous retrovirus HERV-K replication were not detected. Overall, 470 to 1,150 million nucleated cells were grafted into each patient. This case series, with a mean follow-up of almost 2 years, demonstrates that an allogeneic bone scaffold enriched with concentrated autologous bone marrow cells obtained from the iliac crest provides orthopedic surgeons a novel option for treating important bone defects that are unresponsive to traditional therapies

    Outcomes of Elderly Patients with ST-Elevation or Non-ST-Elevation Acute Coronary Syndrome Undergoing Percutaneous Coronary Intervention

    Get PDF
    Introduction: Acute coronary syndromes (ACS) have been classified according to the finding of ST-segment elevation on the presenting electrocardiogram, with different treatment strategies and practice guidelines. However, a comparative description of the clinical characteristics and outcomes of acute coronary syndrome elderly patients undergoing percutaneous coronary intervention during index admission has not been published so far. Methods: Retrospective cohort study of patients enrolled in the Elderly ACS-2 multicenter randomized trial. Main outcome measures were crude cumulative incidence and cause-specific hazard ratio (cHR) of cardiovascular death, noncardiovascular death, reinfarction, and stroke. Results: Of 1443 ACS patients aged >75 years (median age 80 years, interquartile range 77-84), 41% were classified as ST-elevation myocardial infarction (STEMI), and 59% had non-ST-elevation ACS (NSTEACS) (48% NSTEMI and 11% unstable angina). As compared with those with NSTEACS, STEMI patients had more favorable baseline risk factors, fewer prior cardiovascular events, and less severe coronary disease, but lower ejection fraction (45% vs 50%, P <.001). At a median follow-up of 12 months, 51 (8.6%) STEMI patients had died, vs 39 (4.6%) NSTEACS patients. After adjusting for sex, age, and previous myocardial infarction, the hazard among the STEMI group was significantly higher for cardiovascular death (cHR 1.85; 95% confidence interval [CI], 1.02-3.36), noncardiovascular death (cHR 2.10; 95% CI, 1.01-4.38), and stroke (cHR 4.8; 95% CI, 1.7-13.7). Conclusions: Despite more favorable baseline characteristics, elderly STEMI patients have worse survival and a higher risk of stroke compared with NSTEACS patients after percutaneous coronary intervention
    corecore