220 research outputs found

    Hyperechogenic renal parenchyma in potential live related kidney donors: Does it justify exclusion?

    Get PDF
    The aim of this work is to asses theimportance of ultrasonic grade I echogenicity inpotential kidney donors in the absence of urinaryabnormality and with perfect renal function.Thirty four living related kidney donors with thisabnormality were included, age range between 23-48years. Ten matched healthy donors were studied ascontrols.All cases were thoroughly investigated includingmeasuring GFR by isotopic scan and estimation ofrenal reserve by dopamine and aminoacid infusion.Renal biopsy was done for 17 cases of theechogenicity group and 8 controls. Our resultsshowed that the renal reserve was comparable in bothgroups. Glomerular changes were found in 41% ofapparently normal donors and only one case ofcontrols.Conclusion: Grade I echogenicity may be sign ofunrecognised kidney disease. Renal biopsy ismandatory when such related donors are the onlyavailable

    Muscle invasive bladder cancer in Upper Egypt: the shift in risk factors and tumor characteristics

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>In Egypt, where bilharziasis is endemic, bladder cancer is the commonest cancer in males and the 2<sup>nd </sup>in females; squamous cell carcinoma (SCC) is the commonest type found, with a peculiar mode of presentation. The aim of this study is to identify and rank the risk factors of muscle invasive bladder cancer (MIBC) in Upper Egypt and describe its specific criteria of presentation and histopathology.</p> <p>Methods</p> <p>This is an analytical, hospital based, case controlled study conducted in south Egypt cancer institute through comparing MIBC cases (n = 130) with age, sex and residence matched controls (n = 260) for the presence of risk factors of MIBC. Data was collected by personal interview using a well designed questionnaire. Patients' records were reviewed for histopathology and Radiologic findings.</p> <p>Results</p> <p>The risk factors of MIBC were positive family history [Adjusted odds ratio (AOR) = 7.7], exposure to pesticides [AOR = 6.2], bladder stones [AOR = 5], consanguinity [AOR = 3.9], recurrent cystitis [AOR = 3.1], bilharziasis [odds ratio (OR) = 5.8] and smoking [OR = 5.3]. SCC represented 67.6% of cases with burning micturition being the presenting symptom in 73.8%.</p> <p>Conclusion</p> <p>MIBC in Upper Egypt is usually of the SCC type (although its percentage is decreasing), occurs at a younger age and presents with burning micturition rather than hematuria. Unlike the common belief, positive family history, parents' consanguinity, exposure to pesticides and chronic cystitis seem to play now more important roles than bilharziasis and smoking in the development of this disease in this area.</p

    Protocol for the "Michigan Awareness Control Study": A prospective, randomized, controlled trial comparing electronic alerts based on bispectral index monitoring or minimum alveolar concentration for the prevention of intraoperative awareness

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The incidence of intraoperative awareness with explicit recall is 1-2/1000 cases in the United States. The Bispectral Index monitor is an electroencephalographic method of assessing anesthetic depth that has been shown in one prospective study to reduce the incidence of awareness in the high-risk population. In the B-Aware trial, the number needed to treat in order to prevent one case of awareness in the high-risk population was 138. Since the number needed to treat and the associated cost of treatment would be much higher in the general population, the efficacy of the Bispectral Index monitor in preventing awareness in all anesthetized patients needs to be clearly established. This is especially true given the findings of the B-Unaware trial, which demonstrated no significant difference between protocols based on the Bispectral Index monitor or minimum alveolar concentration for the reduction of awareness in high risk patients.</p> <p>Methods/Design</p> <p>To evaluate efficacy in the general population, we are conducting a prospective, randomized, controlled trial comparing the Bispectral Index monitor to a non-electroencephalographic gauge of anesthetic depth. The total recruitment for the study is targeted for 30,000 patients at both low and high risk for awareness. We have developed a novel algorithm that is capable of real-time analysis of our electronic perioperative information system. In one arm of the study, anesthesia providers will receive an electronic page if the Bispectral Index value is >60. In the other arm of the study, anesthesia providers will receive a page if the age-adjusted minimum alveolar concentration is <0.5. Our minimum alveolar concentration algorithm is sensitive to both inhalational anesthetics and intravenous sedative-hypnotic agents.</p> <p>Discussion</p> <p>Awareness during general anesthesia is a persistent problem and the role of the Bispectral Index monitor in its prevention is still unclear. The Michigan Awareness Control Study is the largest prospective trial of awareness prevention ever conducted.</p> <p>Trial Registration</p> <p>Clinical Trial NCT00689091</p

    Lack of robustness of textural measures obtained from 3D brain tumor MRIs impose a need for standardization

    Get PDF
    Purpose Textural measures have been widely explored as imaging biomarkers in cancer. However, their robustness under dynamic range and spatial resolution changes in brain 3D magnetic resonance images (MRI) has not been assessed. The aim of this work was to study potential variations of textural measures due to changes in MRI protocols. Materials and methods Twenty patients harboring glioblastoma with pretreatment 3D T1-weighted MRIs were included in the study. Four different spatial resolution combinations and three dynamic ranges were studied for each patient. Sixteen three-dimensional textural heterogeneity measures were computed for each patient and configuration including co-occurrence matrices (CM) features and run-length matrices (RLM) features. The coefficient of variation was used to assess the robustness of the measures in two series of experiments corresponding to (i) changing the dynamic range and (ii) changing the matrix size. Results No textural measures were robust under dynamic range changes. Entropy was the only textural feature robust under spatial resolution changes (coefficient of variation under 10% in all cases). Conclusion Textural measures of three-dimensional brain tumor images are not robust neither under dynamic range nor under matrix size changes. Standards should be harmonized to use textural features as imaging biomarkers in radiomic-based studies. The implications of this work go beyond the specific tumor type studied here and pose the need for standardization in textural feature calculation of oncological images

    Protocol for the BAG-RECALL clinical trial: a prospective, multi-center, randomized, controlled trial to determine whether a bispectral index-guided protocol is superior to an anesthesia gas-guided protocol in reducing intraoperative awareness with explicit recall in high risk surgical patients

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Awareness with explicit recall of intra-operative events is a rare and distressing complication that may lead to severe psychological symptoms. Candidate depth of anesthesia monitors have been developed, partly with the aim of preventing this complication. Despite conflicting results from clinical trials and the lack of incisive validation, such monitors have enjoyed widespread clinical adoption, in particular the bispectral index. The American Society of Anesthesiologists has called for adequately powered and rigorously designed clinical trials to determine whether the use of such monitors decreases the incidence of awareness in various settings. The aim of this study is to determine with increased precision whether incorporating the bispectral index into a structured general anesthesia protocol decreases the incidence of awareness with explicit recall among a subset of surgical patients at increased risk for awareness and scheduled to receive an inhalation gas-based general anesthetic.</p> <p>Methods/Design</p> <p>BAG-RECALL is a multi-center, randomized, controlled clinical trial, in which 6,000 patients are being assigned to bispectral index-guided anesthesia (target range, 40 to 60) or end-tidal anesthetic gas-guided anesthesia (target range, 0.7 to 1.3 age-adjusted minimum alveolar concentration). Postoperatively, patients are being assessed for explicit recall at two intervals (0 to 72 hours, and 30 days after extubation). The primary outcome of the trial is awareness with explicit recall. Secondary outcomes include postoperative mortality, psychological symptoms, intensive care and hospital length of stay, average anesthetic gas administration, postoperative pain and nausea and vomiting, duration of stay in the recovery area, intra-operative dreaming, and postoperative delirium.</p> <p>Discussion</p> <p>This trial has been designed to complement two other clinical trials: B-Unaware and MACS (ClinicalTrials.gov numbers, NCT00281489 and NCT00689091). With the large patient numbers and complementary rigorous designs, it is envisaged that pre-specified meta-analyses will address some of the outstanding controversies and questions relating to processed electroencephalography monitoring.</p> <p>Trial registration</p> <p>ClinicalTrials.gov Identifier: NCT00682825</p

    At clinically relevant concentrations the anaesthetic/amnesic thiopental but not the anticonvulsant phenobarbital interferes with hippocampal sharp wave-ripple complexes

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Many sedative agents, including anesthetics, produce explicit memory impairment by largely unknown mechanisms. Sharp-wave ripple (SPW-R) complexes are network activity thought to represent the neuronal substrate for information transfer from the hippocampal to neocortical circuits, contributing to the explicit memory consolidation. In this study we examined and compared the actions of two barbiturates with distinct amnesic actions, the general anesthetic thiopental and the anticonvulsant phenobarbital, on in vitro SPW-R activity.</p> <p>Results</p> <p>Using an in vitro model of SPW-R activity we found that thiopental (50–200 μM) significantly and concentration-dependently reduced the incidence of SPW-R events (it increased the inter-event period by 70–430 %). At the concentration of 25 μM, which clinically produces mild sedation and explicit memory impairment, thiopental significantly reduced the quantity of ripple oscillation (it reduced the number of ripples and the duration of ripple episodes by 20 ± 5%, n = 12, <it>P </it>< 0.01), and suppressed the rhythmicity of SPWs by 43 ± 15% (n = 6, <it>P </it>< 0.05). The drug disrupted the synchrony of SPWs within the CA1 region at 50 μM (by 19 ± 12%; n = 5, <it>P </it>< 0.05). Similar effects of thiopental were observed at higher concentrations. Thiopental did not affect the frequency of ripple oscillation at any of the concentrations tested (10–200 μM). Furthermore, the drug significantly prolonged single SPWs at concentrations ≥50 μM (it increased the half-width and the duration of SPWs by 35–90 %). Thiopental did not affect evoked excitatory synaptic potentials and its results on SPW-R complexes were also observed under blockade of NMDA receptors. Phenobarbital significantly accelerated SPWs at 50 and 100 μM whereas it reduced their rate at 200 and 400 μM. Furthermore, it significantly prolonged SPWs, reduced their synchrony and reduced the quantity of ripples only at the clinically very high concentration of 400 μM, reported to affect memory.</p> <p>Conclusion</p> <p>We hypothesize that thiopental, by interfering with SPW-R activity, through enhancement of the GABA<sub>A </sub>receptor-mediated transmission, affects memory processes which involve hippocampal circuit activation. The quantity but not the frequency of ripple oscillation was affected by the drug.</p
    • …
    corecore