224 research outputs found

    Three-year tracking of fatty acid composition of plasma phospholipids in healthy children

    Get PDF
    Objectives: The fatty acid composition of plasma phospholipids reflects the dietary fatty acid intake as well as endogenous turnover. We aimed at investigating the potential tracking of plasma phospholipid fatty acid composition in children that participated in a prospective cohort study. Methods: 26 healthy children participated in a longitudinal study on health risks and had been enrolled after birth. All children were born at term with birth weights appropriate for gestational age. Follow-up took place at ages 24, 36 and 60 months. At each time point a 24-hour dietary recall was obtained, anthropometric parameters were measured and a blood sample for phospholipid fatty acid analysis was taken. Results: Dietary intake of saturated (SFA), monounsaturated (MUFA) and polyunsaturated (PUFA) fatty acids at the three time points were not correlated. We found lower values for plasma MUFA and the MUFA/SFA ratio at 60 months compared to 24 months. In contrast, total PUFA, total n-6 and n-6 long-chain polyunsaturated fatty acids (LC-PUFA) were higher at 60 months. Significant averaged correlation coefficients (average of Pearson's R for 24 versus 36 months and 36 versus 60 months) were found for n-6 LC-PUFA (r = 0.67), n-6/n-3 LC-PUFA ratio (r = 0.59) and arachidonic acid/linoleic acid ratio (r = 0.64). Partial tracking was found for the docosahexaenoic acid/alpha-linolenic acid ratio (r = 0.33). Body mass index and sum of skinfolds Z-scores were similar in the three evaluations. Conclusions: A significant tracking of n-6 LC-PUFA, n-6 LC-PUFA/n-3 LC-PUFA ratio, arachidonic acid/ linoleic acid ratio and docosahexaenoic acid/alpha-linolenic acid ratio may reflect an influence of individual endogenous fatty acid metabolism on plasma concentrations of some, but not all, fatty acids. Copyright (c) 2007 S. Karger AG, Basel

    Lipid-soluble Vitamins A, D, and E in HIV-Infected Pregnant women in Tanzania.

    Get PDF
    There is limited published research examining lipid-soluble vitamins in human immunodeficiency virus (HIV)-infected pregnant women, particularly in resource-limited settings. This is an observational analysis of 1078 HIV-infected pregnant women enrolled in a trial of vitamin supplementation in Tanzania. Baseline data on sociodemographic and anthropometric characteristics, clinical signs and symptoms, and laboratory parameters were used to identify correlates of low plasma vitamin A (<0.7 micromol/l), vitamin D (<80 nmol/l) and vitamin E (<9.7 micromol/l) status. Binomial regression was used to estimate risk ratios and 95% confidence intervals. Approximately 35, 39 and 51% of the women had low levels of vitamins A, D and E, respectively. Severe anemia (hemoglobin <85 g/l; P<0.01), plasma vitamin E (P=0.02), selenium (P=0.01) and vitamin D (P=0.02) concentrations were significant correlates of low vitamin A status in multivariate models. Erythrocyte Sedimentation Rate (ESR) was independently related to low vitamin A status in a nonlinear manner (P=0.01). The correlates of low vitamin D status were CD8 cell count (P=0.01), high ESR (ESR >81 mm/h; P<0.01), gestational age at enrollment (nonlinear; P=0.03) and plasma vitamins A (P=0.02) and E (P=0.01). For low vitamin E status, the correlates were money spent on food per household per day (P<0.01), plasma vitamin A concentration (nonlinear; P<0.01) and a gestational age <16 weeks at enrollment (P<0.01). Low concentrations of lipid-soluble vitamins are widely prevalent among HIV-infected women in Tanzania and are correlated with other nutritional insufficiencies. Identifying HIV-infected persons at greater risk of poor nutritional status and infections may help inform design and implementation of appropriate interventions

    High Density Microarray Analysis Reveals New Insights into Genetic Footprints of Listeria monocytogenes Strains Involved in Listeriosis Outbreaks

    Get PDF
    Listeria monocytogenes, a foodborne bacterial pathogen, causes invasive and febrile gastroenteritis forms of listeriosis in humans. Both invasive and febrile gastroenteritis listeriosis is caused mostly by serotypes 1/2a, 1/2b and 4b strains. The outbreak strains of serotype 1/2a and 4b could be further classified into several epidemic clones but the genetic bases for the diverse pathophysiology have been unsuccessful. DNA microarray provides an important tool to scan the entire genome for genetic signatures that may distinguish the L. monocytogenes strains belonging to different outbreaks. We have designed a pan-genomic microarray chip (Listeria GeneChip) containing sequences from 24 L. monocytogenes strains. The chip was designed to identify the presence/absence of genomic sequences, analyze transcription profiles and identify SNPs. Analysis of the genomic profiles of 38 outbreak strains representing 1/2a, 1/2b and 4b serotypes, revealed that the strains formed distinct genetic clusters adhering to their serotypes and epidemic clone types. Although serologically 1/2a and 1/b strains share common antigenic markers microarray analysis revealed that 1/2a strains are further apart from the closely related 1/2b and 4b strains. Within any given serotype and epidemic clone type the febrile gastroenteritis and invasive strains can be further distinguished based on several genetic markers including large numbers of phage genome, and intergenic sequences. Our results showed that the microarray-based data can be an important tool in characterization of L. monocytogenes strains involved in both invasive and gastroenteritis outbreaks. The results for the first time showed that the serotypes and epidemic clones are based on extensive pan-genomic variability and the 1/2b and 4bstrains are more closely related to each other than the 1/2a strains. The data also supported the hypothesis that the strains causing these two diverse outbreaks are genotypically different and this finding might be important in understanding the pathophysiology of this organism

    Optimizing the diagnostic work-up of acute uncomplicated urinary tract infections

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Most diagnostic tests for acute uncomplicated urinary tract infections (UTIs) have been previously studied in so-called single-test evaluations. In practice, however, clinicians use more than one test in the diagnostic work-up. Since test results carry overlapping information, results from single-test studies may be confounded. The primary objective of the Amsterdam Cystitis/Urinary Tract Infection Study (ACUTIS) is to determine the (additional) diagnostic value of relevant tests from patient history and laboratory investigations, taking into account their mutual dependencies. Consequently, after suitable validation, an easy to use, multivariable diagnostic rule (clinical index) will be derived.</p> <p>Methods</p> <p>Women who contact their GP with painful and/or frequent micturition undergo a series of possibly relevant tests, consisting of patient history questions and laboratory investigations. Using urine culture as the reference standard, two multivariable models (diagnostic indices) will be generated: a model which assumes that patients attend the GP surgery and a model based on telephone contact only. Models will be made more robust using the bootstrap. Discrimination will be visualized in high resolution histograms of the posterior UTI probabilities and summarized as 5<sup>th</sup>, 10<sup>th</sup>, 25<sup>th </sup>50<sup>th</sup>, 75<sup>th</sup>, 90<sup>th</sup>, and 95<sup>th </sup>centiles of these, Brier score and the area under the receiver operating characteristics curve (ROC) with 95% confidence intervals. Using the regression coefficients of the independent diagnostic indicators, a diagnostic rule will be derived, consisting of an efficient set of tests and their diagnostic values.</p> <p>The course of the presenting complaints is studied using 7-day patient diaries. To learn more about the natural history of UTIs, patients will be offered the opportunity to postpone the use of antibiotics.</p> <p>Discussion</p> <p>We expect that our diagnostic rule will allow efficient diagnosis of UTIs, necessitating the collection of diagnostic indicators with proven added value. GPs may use the rule (preferably after suitable validation) to estimate UTI probabilities for women with different combinations of test results. Finally, in a subcohort, an attempt is made to identify which indicators (including antibiotic treatment) are useful to prognosticate recovery from painful and/or frequent micturition.</p

    Limits on WWZ and WW\gamma couplings from p\bar{p}\to e\nu jj X events at \sqrt{s} = 1.8 TeV

    Get PDF
    We present limits on anomalous WWZ and WW-gamma couplings from a search for WW and WZ production in p-bar p collisions at sqrt(s)=1.8 TeV. We use p-bar p -> e-nu jjX events recorded with the D0 detector at the Fermilab Tevatron Collider during the 1992-1995 run. The data sample corresponds to an integrated luminosity of 96.0+-5.1 pb^(-1). Assuming identical WWZ and WW-gamma coupling parameters, the 95% CL limits on the CP-conserving couplings are -0.33<lambda<0.36 (Delta-kappa=0) and -0.43<Delta-kappa<0.59 (lambda=0), for a form factor scale Lambda = 2.0 TeV. Limits based on other assumptions are also presented.Comment: 11 pages, 2 figures, 2 table

    Search For Heavy Pointlike Dirac Monopoles

    Get PDF
    We have searched for central production of a pair of photons with high transverse energies in ppˉp\bar p collisions at s=1.8\sqrt{s} = 1.8 TeV using 70pb170 pb^{-1} of data collected with the D\O detector at the Fermilab Tevatron in 1994--1996. If they exist, virtual heavy pointlike Dirac monopoles could rescatter pairs of nearly real photons into this final state via a box diagram. We observe no excess of events above background, and set lower 95% C.L. limits of 610,870,or1580GeV/c2610, 870, or 1580 GeV/c^2 on the mass of a spin 0, 1/2, or 1 Dirac monopole.Comment: 12 pages, 4 figure

    The Dijet Mass Spectrum and a Search for Quark Compositeness in bar{p}p Collisions at sqrt{s} = 1.8 TeV

    Get PDF
    Using the DZero detector at the 1.8 TeV pbarp Fermilab Tevatron collider, we have measured the inclusive dijet mass spectrum in the central pseudorapidity region |eta_jet| < 1.0 for dijet masses greater than 200 Gev/c^2. We have also measured the ratio of spectra sigma(|eta_jet| < 0.5)/sigma(0.5 < |eta_jet| < 1.0). The order alpha_s^3 QCD predictions are in good agreement with the data and we rule out models of quark compositeness with a contact interaction scale < 2.4 TeV at the 95% confidence level.Comment: 11 pages, 4 figures, 2 tables, submitted to Phys. Rev. Let

    Search for High Mass Photon Pairs in p-pbar --> gamma-gamma-jet-jet Events at sqrt(s)=1.8 TeV

    Get PDF
    A search has been carried out for events in the channel p-barp --> gamma gamma jet jet. Such a signature can characterize the production of a non-standard Higgs boson together with a W or Z boson. We refer to this non-standard Higgs, having standard model couplings to vector bosons but no coupling to fermions, as a "bosonic Higgs." With the requirement of two high transverse energy photons and two jets, the diphoton mass (m(gamma gamma)) distribution is consistent with expected background. A 90(95)% C.L. upper limit on the cross section as a function of mass is calculated, ranging from 0.60(0.80) pb for m(gamma gamma) = 65 GeV/c^2 to 0.26(0.34) pb for m(gamma gamma) = 150 GeV/c^2, corresponding to a 95% C.L. lower limit on the mass of a bosonic Higgs of 78.5 GeV/c^2.Comment: 9 pages, 3 figures. Replacement has new H->gamma gamma branching ratios and corresponding new mass limit

    Zgamma Production in pbarp Collisions at sqrt(s)=1.8 TeV and Limits on Anomalous ZZgamma and Zgammagamma Couplings

    Full text link
    We present a study of Z +gamma + X production in p-bar p collisions at sqrt{S}=1.8 TeV from 97 (87) pb^{-1} of data collected in the eegamma (mumugamma) decay channel with the D0 detector at Fermilab. The event yield and kinematic characteristics are consistent with the Standard Model predictions. We obtain limits on anomalous ZZgamma and Zgammagamma couplings for form factor scales Lambda = 500 GeV and Lambda = 750 GeV. Combining this analysis with our previous results yields 95% CL limits |h{Z}_{30}| < 0.36, |h{Z}_{40}| < 0.05, |h{gamma}_{30}| < 0.37, and |h{gamma}_{40}| < 0.05 for a form factor scale Lambda=750 GeV.Comment: 17 Pages including 2 Figures. Submitted to PR
    corecore