441 research outputs found

    Papillary thyroid cancer associated with syndrome of inappropriate antidiuresis: a case report

    Get PDF
    <p>Abstract</p> <p>Introduction</p> <p>The syndrome of inappropriate antidiuresis is the most common cause of euvolemic hypo-osmolality. This syndrome is associated with a wide variety of diseases. However, its most frequent causes are related to malignancies, especially lung cancer. In this case report, we describe an unknown association of the syndrome of inappropriate antidiuresis with papillary thyroid cancer.</p> <p>Case presentation</p> <p>We present the case of a 71-year-old Caucasian, German woman with marked hyponatremia and neurological symptoms. After a detailed clinical investigation, the common causes of syndrome of inappropriate antidiuresis and other malignancies were ruled out. A thyroid nodule was detected by ultrasound and magnetic resonance imaging. Although fine needle aspiration cytology showed negative results, our patient underwent surgery. Papillary thyroid cancer was later diagnosed. After total thyroidectomy, a complete remission of the clinical symptoms occurred and our patient subsequently had iodine-131 radioactive therapy. Hyponatremia was no longer observed during the follow-up investigations.</p> <p>Conclusion</p> <p>This is the first reported case of paraneoplastic syndrome of inappropriate antidiuresis caused by papillary thyroid carcinoma. Since its symptoms occurred before the development of local symptoms, total thyroidectomy may provide a timely and efficient treatment for the underlying malignancy.</p

    Development and validation of a questionnaire to identify severe maternal morbidity in epidemiological surveys

    Get PDF
    <p>Abstract</p> <p>Objective</p> <p>to develop and validate a questionnaire on severe maternal morbidity and to evaluate the maternal recall of complications related to pregnancy and childbirth. <it>Design: </it>validity of a questionnaire as diagnostic instrument. <it>Setting: </it>a third level referral maternity in Campinas, Brazil. <it>Population: </it>386 survivors of severe maternal complications and 123 women that delivered without major complications between 2002 and 2007.</p> <p>Methods</p> <p>eligible women were traced and interviewed by telephone on the occurrence of obstetric complications and events related to their treatment. Their answers were compared with their medical records as gold standard. Sensitivity, specificity and likelihood ratios plus their correspondent 95% confidence intervals were used as main estimators of accuracy. <it>Main outcomes: </it>diagnosis of severe maternal morbidity associated with past pregnancies, including hemorrhage, eclampsia, infections, jaundice and related procedures (hysterectomy, admission to ICU, blood transfusion, laparotomy, inter-hospital transfer, mechanical ventilation and post partum stay above seven days).</p> <p>Results</p> <p>Women did not recall accurately the occurrence of obstetric complications, especially hemorrhage and infection. The likelihood ratios were < 5 for hemorrhage and infection, while for eclampsia it almost reached 10. The information recalled by women regarding hysterectomy, intensive care unit admission and blood transfusion were found to be highly correlated with finding evidence of the event in the medical records (likelihood ratios ranging from 12.7-240). The higher length of time between delivery and interview was associated with poor recall.</p> <p>Conclusion</p> <p>Process indicators are better recalled by women than obstetric complication and should be considered when applying a questionnaire on severe maternal morbidity.</p

    Limits on WWZ and WW\gamma couplings from p\bar{p}\to e\nu jj X events at \sqrt{s} = 1.8 TeV

    Get PDF
    We present limits on anomalous WWZ and WW-gamma couplings from a search for WW and WZ production in p-bar p collisions at sqrt(s)=1.8 TeV. We use p-bar p -> e-nu jjX events recorded with the D0 detector at the Fermilab Tevatron Collider during the 1992-1995 run. The data sample corresponds to an integrated luminosity of 96.0+-5.1 pb^(-1). Assuming identical WWZ and WW-gamma coupling parameters, the 95% CL limits on the CP-conserving couplings are -0.33<lambda<0.36 (Delta-kappa=0) and -0.43<Delta-kappa<0.59 (lambda=0), for a form factor scale Lambda = 2.0 TeV. Limits based on other assumptions are also presented.Comment: 11 pages, 2 figures, 2 table

    Search For Heavy Pointlike Dirac Monopoles

    Get PDF
    We have searched for central production of a pair of photons with high transverse energies in ppˉp\bar p collisions at s=1.8\sqrt{s} = 1.8 TeV using 70pb170 pb^{-1} of data collected with the D\O detector at the Fermilab Tevatron in 1994--1996. If they exist, virtual heavy pointlike Dirac monopoles could rescatter pairs of nearly real photons into this final state via a box diagram. We observe no excess of events above background, and set lower 95% C.L. limits of 610,870,or1580GeV/c2610, 870, or 1580 GeV/c^2 on the mass of a spin 0, 1/2, or 1 Dirac monopole.Comment: 12 pages, 4 figure

    The Dijet Mass Spectrum and a Search for Quark Compositeness in bar{p}p Collisions at sqrt{s} = 1.8 TeV

    Get PDF
    Using the DZero detector at the 1.8 TeV pbarp Fermilab Tevatron collider, we have measured the inclusive dijet mass spectrum in the central pseudorapidity region |eta_jet| < 1.0 for dijet masses greater than 200 Gev/c^2. We have also measured the ratio of spectra sigma(|eta_jet| < 0.5)/sigma(0.5 < |eta_jet| < 1.0). The order alpha_s^3 QCD predictions are in good agreement with the data and we rule out models of quark compositeness with a contact interaction scale < 2.4 TeV at the 95% confidence level.Comment: 11 pages, 4 figures, 2 tables, submitted to Phys. Rev. Let

    Search for High Mass Photon Pairs in p-pbar --> gamma-gamma-jet-jet Events at sqrt(s)=1.8 TeV

    Get PDF
    A search has been carried out for events in the channel p-barp --> gamma gamma jet jet. Such a signature can characterize the production of a non-standard Higgs boson together with a W or Z boson. We refer to this non-standard Higgs, having standard model couplings to vector bosons but no coupling to fermions, as a "bosonic Higgs." With the requirement of two high transverse energy photons and two jets, the diphoton mass (m(gamma gamma)) distribution is consistent with expected background. A 90(95)% C.L. upper limit on the cross section as a function of mass is calculated, ranging from 0.60(0.80) pb for m(gamma gamma) = 65 GeV/c^2 to 0.26(0.34) pb for m(gamma gamma) = 150 GeV/c^2, corresponding to a 95% C.L. lower limit on the mass of a bosonic Higgs of 78.5 GeV/c^2.Comment: 9 pages, 3 figures. Replacement has new H->gamma gamma branching ratios and corresponding new mass limit

    Zgamma Production in pbarp Collisions at sqrt(s)=1.8 TeV and Limits on Anomalous ZZgamma and Zgammagamma Couplings

    Full text link
    We present a study of Z +gamma + X production in p-bar p collisions at sqrt{S}=1.8 TeV from 97 (87) pb^{-1} of data collected in the eegamma (mumugamma) decay channel with the D0 detector at Fermilab. The event yield and kinematic characteristics are consistent with the Standard Model predictions. We obtain limits on anomalous ZZgamma and Zgammagamma couplings for form factor scales Lambda = 500 GeV and Lambda = 750 GeV. Combining this analysis with our previous results yields 95% CL limits |h{Z}_{30}| < 0.36, |h{Z}_{40}| < 0.05, |h{gamma}_{30}| < 0.37, and |h{gamma}_{40}| < 0.05 for a form factor scale Lambda=750 GeV.Comment: 17 Pages including 2 Figures. Submitted to PR

    A Measurement of the W Boson Mass

    Full text link
    We report a measurement of the W boson mass based on an integrated luminosity of 82 pb1^{-1} from \ppbar collisions at s=1.8\sqrt{s}=1.8 TeV recorded in 1994--1995 by the \Dzero detector at the Fermilab Tevatron. We identify W bosons by their decays to eνe\nu and extract the mass by fitting the transverse mass spectrum from 28,323 W boson candidates. A sample of 3,563 dielectron events, mostly due to Z to ee decays, constrains models of W boson production and the detector. We measure \mw=80.44\pm0.10(stat)\pm0.07(syst)~GeV. By combining this measurement with our result from the 1992--1993 data set, we obtain \mw=80.43\pm0.11 GeV.Comment: 11 pages, 5 figure
    corecore