2,524 research outputs found

    Targeted Attacks: Redefining Spear Phishing and Business Email Compromise

    Full text link
    In today's digital world, cybercrime is responsible for significant damage to organizations, including financial losses, operational disruptions, or intellectual property theft. Cyberattacks often start with an email, the major means of corporate communication. Some rare, severely damaging email threats - known as spear phishing or Business Email Compromise - have emerged. However, the literature disagrees on their definition, impeding security vendors and researchers from mitigating targeted attacks. Therefore, we introduce targeted attacks. We describe targeted-attack-detection techniques as well as social-engineering methods used by fraudsters. Additionally, we present text-based attacks - with textual content as malicious payload - and compare non-targeted and targeted variants

    Live Blog Corpus for Summarization

    Full text link
    Live blogs are an increasingly popular news format to cover breaking news and live events in online journalism. Online news websites around the world are using this medium to give their readers a minute by minute update on an event. Good summaries enhance the value of the live blogs for a reader but are often not available. In this paper, we study a way of collecting corpora for automatic live blog summarization. In an empirical evaluation using well-known state-of-the-art summarization systems, we show that live blogs corpus poses new challenges in the field of summarization. We make our tools publicly available to reconstruct the corpus to encourage the research community and replicate our results.Comment: To appear in the Proceedings of LREC 201

    C-terminal phosphorylation of NaV1.5 impairs FGF13-dependent regulation of channel inactivation

    Get PDF
    International audienceVoltage-gated Na(+) (NaV) channels are key regulators of myocardial excitability, and Ca(2+)/calmodulin-dependent protein kinase II (CaMKII)-dependent alterations in NaV1.5 channel inactivation are emerging as a critical determinant of arrhythmias in heart failure. However, the global native phosphorylation pattern of NaV1.5 subunits associated with these arrhythmogenic disorders and the associated channel regulatory defects remain unknown. Here, we undertook phosphoproteomic analyses to identify and quantify in situ the phosphorylation sites in the NaV1.5 proteins purified from adult WT and failing CaMKIIδc-overexpressing (CaMKIIδc-Tg) mouse ventricles. Of 19 native NaV1.5 phosphorylation sites identified, two C-terminal phosphoserines at positions 1938 and 1989 showed increased phosphorylation in the CaMKIIδc-Tg compared with the WT ventricles. We then tested the hypothesis that phosphorylation at these two sites impairs fibroblast growth factor 13 (FGF13)-dependent regulation of NaV1.5 channel inactivation. Whole-cell voltage-clamp analyses in HEK293 cells demonstrated that FGF13 increases NaV1.5 channel availability and decreases late Na(+) current, two effects that were abrogated with NaV1.5 mutants mimicking phosphorylation at both sites. Additional co-immunoprecipitation experiments revealed that FGF13 potentiates the binding of calmodulin to NaV1.5 and that phosphomimetic mutations at both sites decrease the interaction of FGF13 and, consequently, of calmodulin with NaV1.5. Together, we have identified two novel native phosphorylation sites in the C terminus of NaV1.5 that impair FGF13-dependent regulation of channel inactivation and may contribute to CaMKIIδc-dependent arrhythmogenic disorders in failing hearts

    Diagnostic Benefit of High b-Value Computed Diffusion-Weighted Imaging in Patients with Hepatic Metastasis

    Get PDF
    Diffusion-weighted imaging (DWI) has rapidly become an essential tool for the detection of malignant liver lesions. The aim of this study was to investigate the usefulness of high b-value computed DWI (c-DWI) in comparison to standard DWI in patients with hepatic metastases. In total, 92 patients with histopathologic confirmed primary tumors with hepatic metastasis were retrospectively analyzed by two readers. DWI was obtained with b-values of 50, 400 and 800 or 1000 s/mm2 on a 1.5 T magnetic resonance imaging (MRI) scanner. C-DWI was calculated with a monoexponential model with high b-values of 1000, 2000, 3000, 4000 and 5000 s/mm2. All c-DWI images with high b-values were compared to the acquired DWI sequence at a b-value of 800 or 1000 s/mm2 in terms of volume, lesion detectability and image quality. In the group of a b-value of 800 from a b-value of 2000 s/mm2, hepatic lesion sizes were significantly smaller than on acquired DWI (metastases lesion sizes b = 800 vs. b 2000 s/mm2: mean 25 cm3 (range 10–60 cm3) vs. mean 17.5 cm3 (range 5–35 cm3), p < 0.01). In the second group at a high b-value of 1500 s/mm2, liver metastases were larger than on c-DWI at higher b-values (b = 1500 vs. b 2000 s/mm2, mean 10 cm3 (range 4–24 cm3) vs. mean 9 cm3 (range 5–19 cm3), p < 0.01). In both groups, there was a clear reduction in lesion detectability at b = 2000 s/mm2, with hepatic metastases being less visible compared to c-DWI images at b = 1500 s/mm2 in at least 80% of all patients. Image quality dropped significantly starting from c-DWI at b = 3000 s/mm2. In both groups, almost all high b-values images at b = 4000 s/mm2 and 5000 s/mm2 were not diagnostic due to poor image quality. High c-DWI b-values up to b = 1500 s/mm2 offer comparable detectability for hepatic metastases compared to standard DWI. Higher b-value images over 2000 s/mm2 lead to a noticeable reduction in imaging quality, which could hamper diagnosis

    La recherche sur estampe : où en est-on ?

    Get PDF
    Cette table ronde a discuté de la recherche en estampe ancienne en explorant deux directions. Une première partie a constitué davantage en un bilan historiographique sur les recherches menées depuis deux décennies dans le domaine de l’estampe ancienne, et une deuxième partie a traité de problématiques plus larges. Maxime Préaud a inauguré la table ronde en rappelant qu’il s’était livré à un bilan similaire sur les recherches menées depuis plus de trente ans en matière d’estampe ancienne, et p..

    Magnetic Resonance Imaging of Peritoneal Carcinomatosis: Evaluation of High b-Value Computed Diffusion-Weighted Imaging

    Get PDF
    Over the last few years, diffusion-weighted imaging (DWI) has become increasingly relevant in the diagnostic assessment of peritoneal carcinomatosis. The aim of this study was to investigate the benefits of high-b DWI (c-DWI) compared to standard DWI in patients with peritoneal carcinomatosis. A cohort of 40 patients with peritoneal carcinomatosis were included in this retrospective study. DWI was performed with b-values of 50, 400, and 800 or 1000 s/mm2 on a 1.5-T magnetic resonance imaging (MRI) scanner. C-DWI was calculated using a mono-exponential model with high b-values of 1000, 2000, 3000, 4000, and 5000 s/mm2. All c-DWI images with high b-values were compared in terms of volume, detectability of peritoneal lesions, and image quality with the DWI sequence acquired with a b-value of 800 or 1000 s/mm2 by two readers. In the group with a b-value of 800 s/mm2, there was no statistically significant difference in terms of lesion volume. In the second group with a b-value of 1000 s/mm2, peritoneal carcinomatosis lesions were statistically significantly larger than in the c-DWI with a- high b-value of 2000 s/mm2 (median 7 cm3, range 1–26 cm3vs. median 6 cm3, range 1–83 cm3, p < 0.05). In both groups, there was a marked decrease in the detectability of peritoneal lesions starting at b = 2000 s/mm2. In addition, image quality decreased noticeably from c-DWI at b = 3000 s/mm2. In both groups, all images with high b-values at b = 4000 s/mm2 and 5000 s/mm2 were not diagnostically valuable due to poor image quality. The c-DWI technique offers good diagnostic performance without additional scanning time. High c-DWI b-values up to b = 1000 s/mm2 provide comparable detectability of peritoneal carcinomatosis compared to standard DWI. Higher b-values over 1500 s/mm2 result in lower image quality, which might lead to misdiagnosis
    • …
    corecore