22 research outputs found

    LIQUID-DROP COLLIDER TO SIMULATE NUCLEAR-REACTIONS

    No full text

    Thermoluminescent response of TLD-100 exposed to low energy protons

    No full text
    The fluence response curve of LiF:Mg,Ti (TLD-100) exposed to 0.7, 1.5 and 3 MeV proton beams has been measured. In all cases, the total TL signal and glow curve peaks 5 to 9 show a linear-supralinear response for fluences between 10(7) and 10(12) protons/cm(2). The supralinearity increases with the energy of the incident beam. The measured relative efficiencies for protons with respect to Co-60 gamma-rays, for the total TL signal and peaks 5 and 7 indicate that the efficiency increases with energy, that is, decreases with the linear energy transfer. The efficiencies are lower than unity for the total TL signal and peak 5 and greater than unity for peak 7

    Thermoluminescent response of TLD-100 to low energy protons

    No full text
    The fluence-response curve of LiF:Mg,Ti (TLD-100) exposed to 0.7, 1.5 and 3 MeV protons has been measured in the 10(7)-10(12) protons.cm(-2) fluence range. The total TL signal and glow curve peaks show in all cases a linear-supralinear response and the degree of supralinearity increases with the energy of the incident beam and the temperature of the TL peak. The possible effect on the results of alternative glow curve deconvolutions has been studied, finding only minor differences in the supralinearity functions for individual peaks. Measurements for peaks 5 and 8 have been compared with track interaction model (TIM and UNIM) predictions, and it is concluded that the assumption that Omega scales with LET fails to describe the observed energy dependence of the supralinearity

    Sublinear response of peak 5 in LiF : Mg,Ti to low energy protons and carbon ions

    No full text
    This work analyses experimentally and mathematically the heavy charged particle (HCP) thermoluminescence (TL) fluence response of sensitised LiF:Mg,Ti (TLD-100) peak 5 to 0.91, 2.95 and 4.32 MeV protons and 10.3 and 11.8 MeV carbon ions. Supralinearity was suppressed by sensitising the TLD-100 chips following a pre-exposure/annealing treatment. HCP irradiations took place using a Pelletron accelerator at fluences that ranged from about 6 x 10(8) to 3 x 10(11) cm(-2) and from 3 x 10(7) to 1 x 10(11) cm(-2) for protons and carbons, respectively. Results were compared to a Monte Carlo simulation of the Extended Track Interaction Model (ETIM) performed for each particle-energy combination. Experimental data show that the onset and behaviour of the HCP-TL fluence response function is weakly energy dependent for each ion type, in agreement with previously reported data of sensitised TLD-100 irradiated with low energy helium ions. ETIM fails to predict this behaviour showing instead a strong energy dependence of the simulated HCP-TL fluence response function. (C) 2004 Elsevier B.V. All rights reserved

    TLD-100 thermoluminescent efficiencies for low-energy ions: correlation of efficiency with ion incident energy

    No full text
    A systematic investigation of heavy charged particle-to-gamma thermoluminescent (TL) efficiencies has been performed for the total signal and peak 5 of LiF : Mg, Ti (TLD-100) dosemeters. Experimental and theoretical efficiencies are presented for protons as well as helium, carbon, nitrogen and oxygen ions. Proton, helium and carbon irradiations were performed at incident energies between 0.7 and 11 MeV. For nitrogen and oxygen, two energies, corresponding to 'mirror' values below and above the Bragg peak energy, were used to measure TL efficiencies for the same linear energy transfer (LET) entrance value. The energies chosen were 4.83 and 9.95 MeV for nitrogen ions and 6.02 and 12.95 MeV for oxygen ions. Distinct curves are found for each ion species. Data for energies higher than the Bragg peak energy follow the well-known tendency, efficiency values decrease with increasing LET. Efficiencies measured below the Bragg peak display the opposite effect, efficiency increases with increasing LET. Presenting results as a function of incident energy shows a monotonic and single valued behaviour, efficiency decreases with decreasing energy. The measured efficiencies of the higher-energy data (above the Bragg peak) were found to be 1.45 times greater than their low-energy counterparts. Modified track structure theory efficiency calculations were performed for all the ions investigated using radial dose distributions obtained via Monte Carlo simulations in solid-state LiF and 8.1 keV x-rays as test radiation. The theoretical values show agreement with data within 40% for both peak 5 and the total signal. The calculations predict the observed behaviour, higher efficiency for higher ion energy

    On the correct measurement of relative heavy charged particles to gamma thermoluminescent efficiencies

    No full text
    In order to better understand the most important experimental aspects for performing correct measurements of relative thermoluminescent (TL) efficiencies, an investigation has been carried out to quantify the effect of using different experimental procedures in the evaluation of 3 MeV proton-to-gamma relative efficiency (eta(p,gamma)) of LiF:Mg,Ti. Variations in batch, presentation, annealing and reader have been studied. When the same protocol is used to measure proton and gamma TL response, efficiency values obtained range from 0.36 to 0.59 for peak 5 and from 0.44 to 0.79 for the total signal. The use of different annealings and different batches leads to 20% and 10% differences in eta(p,gamma), respectively. Large differences (40%) are found between efficiency values measured with TLD-100 chips and those obtained using TLD-100 microcubes. When 'mixed' procedures are used to measure the proton and the gamma response, differences in eta(p,gamma), may increase even more. The main conclusion of this work is to stress the importance of measuring an entire series of experiments in the same laboratory with a carefully defined protocol and using dosemeters from the same batch to obtain heavy charged particle TL response and gamma TL response with identical annealing and readout procedures

    Response of radiochromic dye films to low energy heavy charged particles

    No full text
    We have studied the possible use of radiochromic dye films (RCF) as heavy charged particle dosemeters. We present the results of irradiating two commercial RCF (GafChromic HD-810 and MD-55-1) with 1.5, 2.9 and 4.4 MeV protons, 1.4, 2.8, 4.7, 5.9, 6.8 MeV He-4 ions and 8.5 and 12.4 MeV C-12 ions, at proton doses from about 1 Gy up to 3 kGy, helium ions doses from 3 Gy to 5 kGy and carbon ion doses from 30 Gy to 20 kGy. The films were scanned and digitized using commercial equipment. For a given particle, the response per unit dose at different energies indicates an energy dependence of the sensitivity, which is discussed. Comparison was made for the use of a standard spectrophotometer to obtain optical density readings versus a white light scanner. (C) 2002 Elsevier Science B.V. All rights reserved

    Atomic effects in heavy-ion elastic scattering

    Get PDF
    Angular distributions of a Pb-208 beam on Pb-208 thin targets at very small angles were measured. The shape of the experimental distribution is not Gaussian, indicating a plural scattering regime rather than multiple scattering. The distribution was well reproduced by a Monte Carlo simulation of the straggling process. For the first time we observed and quantified the influence of the production of electrons during the scattering. This effect was observed in the angular correlation of the scattered Pb-208 nuclei detected in kinematic coincidence and also in the limiting angle of the Pb-208 scattered in a Ag-107,Ag-109 target. This effect introduces a spread in the scattered angle which is of the same order of magnitude as the angular straggling
    corecore