2,367 research outputs found
Recommended from our members
Measurement of post-lens tear thickness.
PURPOSE: A method to measure the tear film beneath a soft contact lens, referred to as post-lens tear thickness (PLTT), would have many applications to contact lens research. In this study a noninvasive technique for measuring the PLTT is presented. METHODS: The feasibility of measuring the tear layer by optical pachometry was first assessed using a model eye. The baseline corneal thickness (B) of both eyes of 21 subjects was measured, etafilcon-A ionic disposable soft contact lenses (58% water) were inserted, and the total thickness (T) of the cornea, contact lens, and PLTT were measured. After the pachometry readings the lenses were removed and their center thickness (C) determined. The PLTT was calculated using the equation: PLTT = T-(B+C). Two sets of measurements of T were performed at 15 and 25 minutes after lens insertion. The entire procedure was repeated at a second visit. RESULTS: The pachometry measurements of the small aqueous reservoir between the model eye and the lens closely matched those obtained by direct microscopic measurement. For human PLTT, the mean values (and 95% confidence intervals) for right eyes on visits 1 and 2 were 11 (8, 13) and 12 (10, 15) microm, respectively, and for left eyes were 12 (10, 15) and 11 microm (8, 14) microm, respectively. CONCLUSIONS: It is possible to measure the post-lens tear thickness using optical pachometry. The variability between repeated measurements suggests that with careful sample size planning, the technique is sufficiently precise to be useful in group assessments of PLTT
A new bound on axion-like particles
Axion-like particles (ALPs) and photons can quantum mechanically interconvert
when propagating through magnetic fields, and ALP-photon conversion may induce
oscillatory features in the spectra of astrophysical sources. We use deep (370
ks), short frame time Chandra observations of the bright nucleus at the centre
of the radio galaxy M87 in the Virgo cluster to search for signatures of light
ALPs. The absence of substantial irregularities in the X-ray power-law spectrum
leads to a new upper limit on the photon-ALP coupling, : using a
conservative model of the cluster magnetic field consistent with Faraday
rotation measurements from M87 and M84, we find GeV at 95% confidence level for ALP masses eV. Other consistent magnetic field models lead to stronger limits of
-- GeV. These bounds are
all stronger than the limit inferred from the absence of a gamma-ray burst from
SN1987A, and rule out a substantial fraction of the parameter space accessible
to future experiments such as ALPS-II and IAXO
Recommended from our members
The Berkeley Contact Lens Extended Wear Study. Part I : Study design and conduct.
ObjectiveThe primary aim of the Berkeley Contact Lens Extended Wear Study (CLEWS) was to test the hypotheses that extended wear of rigid gas-permeable (RGP) contact lenses with greater oxygen permeability (Dk) reduces the incidence of contact lens-associated keratopathy (CLAK) and increases the survival rate in RGP extended wear (EW). In this article we describe the clinical trial design in detail, present the results of subject recruitment and retention, and provide the baseline demographic and ocular characteristics of the CLEWS subjects, whose data will be analyzed to address the study aims in a companion article.DesignA randomized, concurrently controlled clinical trial.InterventionSubjects were fitted with day wear (DW) high-Dk RGP lenses and then adapted to EW. Subjects who adapted to EW were then randomly assigned to either high- or medium-Dk RGP lenses for 12 months of 6-nights/week EW.Main outcome measuresSlit-lamp assessment and grading of 17 possible keratopathies, measurement of refractive error and corneal curvature, and symptoms. Follow-up data were collected every 3 months.ResultsFrom 545 subjects entering the DW adaptation phase, 201 adapted to EW and were randomly assigned to medium- or high-Dk lenses for 12 months of EW. The baseline characteristics of the two study groups were similar and did not differ from the 344 DW subjects who failed to adapt to EW. The distributions of oxygen transmissibility for the two study groups were disjoint, indicating that each group received distinctly different levels of hypoxia.ConclusionsWe show that CLEWS was appropriately designed to address the study hypotheses, was conducted with regard for the safety of the subjects, and adhered to rigorous protocols designed to control for bias and ensure the integrity of study data. We establish the internal validity of between-group statistical comparisons and characterize our study population to permit informed evaluation of the applicability of our results to the contact lens-wearing population in general
Recommended from our members
The Berkeley Contact Lens Extended Wear Study. Part II : Clinical results.
ObjectiveTo describe the principal clinical outcomes associated with 12 months use of rigid gas-permeable (RGP) extended wear contact lenses and address two primary study questions: (1) does extended wear (EW) of high oxygen transmissibility (Dk/t) RGP lenses reduce the incidence of ocular complications, and (2) does the wearing of high-Dk/t lenses reduce the rate of failure to maintain 6-night RGPEW over 12 months?DesignA randomized, concurrently controlled clinical trial.InterventionSubjects who adapted to EW with high Dk (oxygen permeability) RGP lenses were randomized to either high Dk or medium-Dk RGP lenses for 12 months of 6-night EW.Main outcome measuresContact lens-associated keratopathies (CLAK), changes in refractive error and corneal curvature, and survival in EW.ResultsTwo hundred one subjects were randomized to medium or high-Dk lenses for 12 months of EW. Sixty-two percent of the subjects in each group completed 12 months of EW; however, the probability of failure was significantly greater for the medium-Dk group. Although the risk of complications was similar for the two groups, the number of CLAK events that led to termination were 16 versus 5 for the medium-Dk and high-Dk groups, respectively. This suggests that the type of adverse response or the inability to reverse an adverse event was different for the group being exposed to the lower oxygen dose.ConclusionsThe level of oxygen available to the cornea has a significant impact on maintaining successful RGP extended contact lens wear, but not on the initial onset of CLAK. The number of clinical events leading to termination was substantially higher for the medium Dk group, which suggests that corneal hypoxia is an important factor in the development of CLAK. Although overnight contact lens wear should be recommended with caution and carefully monitored for early detection of ocular complications, it appears that high-Dk RGP lenses can be a safe and effective treatment for correction of refractive error for most individuals who can adapt to EW
Recommended from our members
The effects of one-hour wear of high-Dk soft contact lenses on corneal pH and epithelial permeability.
PurposePrevious studies have shown that 1-hour closed-eye contact lens wear with a low-Dk lens causes a significant reduction in corneal pH and an increase in epithelial permeability. In the present study, we evaluated the effects of super-high-Dk/t soft lenses on corneal epithelial barrier function and stromal pH.MethodsCorneal thickness was measured by optical pachometry, while epithelial permeability and stromal pH were measured by fluorophotometry. A paired-eye design was used in which one eye was randomly allocated to wear a high-oxygen-permeable soft lens (CIBAVision Focus/NIGHT & DAY (Dk/t= 175) while the other eye did not wear a lens.ResultsAfter 1-hour closed-eye lens wear, neither the difference in corneal swelling (P = 0.206) nor the permeability (P = 0.055) between both eyes was significantly different. The mean pH values under open-eye conditions were 7.66 vs. 7.57 for the treatment and control eyes, respectively (P = 0.082), dropping to 7.27 vs. 7.25 after 1-hour eye closure (P = 0.283).ConclusionsAlthough our results are limited to a 1-hour observation period, they do provide evidence that high-Dk materials may eliminate corneal acidosis and reduced epithelial barrier function that accompany closed-eye contact lens wear with lower-Dk soft lens materials
ReadNet: A Hierarchical Transformer Framework for Web Article Readability Analysis
Analyzing the readability of articles has been an important sociolinguistic
task. Addressing this task is necessary to the automatic recommendation of
appropriate articles to readers with different comprehension abilities, and it
further benefits education systems, web information systems, and digital
libraries. Current methods for assessing readability employ empirical measures
or statistical learning techniques that are limited by their ability to
characterize complex patterns such as article structures and semantic meanings
of sentences. In this paper, we propose a new and comprehensive framework which
uses a hierarchical self-attention model to analyze document readability. In
this model, measurements of sentence-level difficulty are captured along with
the semantic meanings of each sentence. Additionally, the sentence-level
features are incorporated to characterize the overall readability of an article
with consideration of article structures. We evaluate our proposed approach on
three widely-used benchmark datasets against several strong baseline
approaches. Experimental results show that our proposed method achieves the
state-of-the-art performance on estimating the readability for various web
articles and literature.Comment: ECIR 202
Fluorescence characterization of clinically-important bacteria
Healthcare-associated infections (HCAI/HAI) represent a substantial threat to patient health during hospitalization and incur billions of dollars additional cost for subsequent treatment. One promising method for the detection of bacterial contamination in a clinical setting before an HAI outbreak occurs is to exploit native fluorescence of cellular molecules for a hand-held, rapid-sweep surveillance instrument. Previous studies have shown fluorescence-based detection to be sensitive and effective for food-borne and environmental microorganisms, and even to be able to distinguish between cell types, but this powerful technique has not yet been deployed on the macroscale for the primary surveillance of contamination in healthcare facilities to prevent HAI. Here we report experimental data for the specification and design of such a fluorescence-based detection instrument. We have characterized the complete fluorescence response of eleven clinically-relevant bacteria by generating excitation-emission matrices (EEMs) over broad wavelength ranges. Furthermore, a number of surfaces and items of equipment commonly present on a ward, and potentially responsible for pathogen transfer, have been analyzed for potential issues of background fluorescence masking the signal from contaminant bacteria. These include bedside handrails, nurse call button, blood pressure cuff and ward computer keyboard, as well as disinfectant cleaning products and microfiber cloth. All examined bacterial strains exhibited a distinctive double-peak fluorescence feature associated with tryptophan with no other cellular fluorophore detected. Thus, this fluorescence survey found that an emission peak of 340nm, from an excitation source at 280nm, was the cellular fluorescence signal to target for detection of bacterial contamination. The majority of materials analysed offer a spectral window through which bacterial contamination could indeed be detected. A few instances were found of potential problems of background fluorescence masking that of bacteria, but in the case of the microfiber cleaning cloth, imaging techniques could morphologically distinguish between stray strands and bacterial contamination
Birthweight and risk markers for type 2 diabetes and cardiovascular disease in childhood: the Child Heart and Health Study in England (CHASE).
AIMS/HYPOTHESIS: Lower birthweight (a marker of fetal undernutrition) is associated with higher risks of type 2 diabetes and cardiovascular disease (CVD) and could explain ethnic differences in these diseases. We examined associations between birthweight and risk markers for diabetes and CVD in UK-resident white European, South Asian and black African-Caribbean children.
METHODS: In a cross-sectional study of risk markers for diabetes and CVD in 9- to 10-year-old children of different ethnic origins, birthweight was obtained from health records and/or parental recall. Associations between birthweight and risk markers were estimated using multilevel linear regression to account for clustering in children from the same school.
RESULTS: Key data were available for 3,744 (66%) singleton study participants. In analyses adjusted for age, sex and ethnicity, birthweight was inversely associated with serum urate and positively associated with systolic BP. After additional height adjustment, lower birthweight (per 100 g) was associated with higher serum urate (0.52%; 95% CI 0.38, 0.66), fasting serum insulin (0.41%; 95% CI 0.08, 0.74), HbA1c (0.04%; 95% CI 0.00, 0.08), plasma glucose (0.06%; 95% CI 0.02, 0.10) and serum triacylglycerol (0.30%; 95% CI 0.09, 0.51) but not with BP or blood cholesterol. Birthweight was lower among children of South Asian (231 g lower; 95% CI 183, 280) and black African-Caribbean origin (81 g lower; 95% CI 30, 132). However, adjustment for birthweight had no effect on ethnic differences in risk markers.
CONCLUSIONS/INTERPRETATION: Birthweight was inversely associated with urate and with insulin and glycaemia after adjustment for current height. Lower birthweight does not appear to explain emerging ethnic difference in risk markers for diabetes
- …