2,772 research outputs found

    Leaving hip rotation out of a conventional 3D gait model improves discrimination of pathological gait in cerebral palsy: A novel neural network analysis

    Get PDF
    Background: Complex clinical gait analysis results can be expressed as single number gait deviations by applying multivariate processing methods. The original Movement Deviation Profile (MDP) quantifies the deviation of abnormal gait using the most trusted nine dynamic joint angles of lower limbs. Research question: Which subset of joint angles maximises the ability of the MDP to separate abnormal gait from normality? What is the effect of using the best subset in a large group of patients, and in individuals? Methods: A self-organising neural network was trained using normal gait data from 166 controls, and then the MDP of 1923 patients with cerebral palsy (3846 legs) was calculated. The same procedure was repeated with 511 combinations of the nine joint angles. The standardised distances of abnormal gait from normality were then calculated as log-transformed Z-scores to select the best combination. A mixed design ANOVA was used to assess how removing the least discriminating angle improved the separation of patients from controls. The effect of using the optimal subset of angles was also quantified for each individual leg by comparing the change in MDP to the independent FAQ levels of patients. Results: Removal of hip rotation significantly (p<0.0005) increased the separation of the patient group from normality (ΔZ-score 0.24) and also at FAQ levels 7-10 (ΔZ-score 0.38, 0.27, 0.22, 0.14). The MDP of individual patients changed in a wider range of -4.65 to 1.12 Z-scores and their change matched their independent FAQ scores, with less functional patients moving further from, and more functional patients moving closer to normality. Significance: In existing gait databases we recommend excluding hip rotation from data used to calculate the MDP. Alternatively, the calculation of hip rotation can be improved by post-hoc correction, but the ultimate solution is to use more accurate and reliable models of hip rotation. © 201

    Histological heterogeneity of glomerular segmental lesions in focal segmental glomerulosclerosis

    Get PDF
    Focal segmental glomerulosclerosis (FSGS) involves considerable histological heterogeneity in terms of location and quality of the glomerular segmental lesions. The present study investigated the heterogeneity of segmental lesions in each variant of FSGS, determined by the Columbia classification, and its clinical relevance. All glomerular segmental lesions of 80 cases of primary FSGS were evaluated histologically based on location [tip (TIP), perihilar (PH), or not otherwise specified (NOS)], and quality (cellular or fibrous). Among the 1,299 glomeruli of the 80 biopsy specimens, 210 glomeruli (16.2%) had segmental lesions, comprising 57 (27%) cellular TIP, 4 (2%) fibrous TIP, 42 (20%) cellular NOS, 86 (41%) fibrous NOS, and 21 (10%) fibrous PH lesions. Each case was also classified into one of the five histological variants of the Columbia classification: collapsing (COL), TIP, cellular (CEL), PH, or NOS. Overlap of segmental lesions in different location categories was seen in the COL, TIP, and PH variants, and heterogeneity of quality was apparent in the COL and CEL variants. Histological findings of the CEL variant (endocapillary hypercellularity) were observed in nine of the 13 COL variants. Both location and quality correlated with disease duration, degree of proteinuria, and histological severity of global glomerular sclerosis and tubulo-interstitial lesions. These results demonstrated the histological heterogeneity of glomerular segmental lesions in all variants of the Columbia classification, except NOS. However, the fidelity of location and dominance of histological features were generally conserved in the TIP and PH variants. The COL and CEL variants warrant further investigation because of their overlapping histological findings and apparent histological heterogeneity in the glomerular segmental lesions

    Quality of Pharmaceutical Industry Press Releases Based on Original Research

    Get PDF
    Background: Press releases are a popular vehicle to disseminate health information to the lay media. While the quality of press releases issued by scientific conferences and medical journals has been questioned, no efforts to assess pharmaceutical industry press releases have been made. Therefore, we sought to systematically examine pharmaceutical company press releases about original research for measures of quality. Methodolgy/Principal Findings: Press releases issued by the ten top selling, international pharmaceutical companies in the year 2005 were selected for evaluation. A total of 1028 electronic press releases were issued and 235 were based on original research. More than half (59%) reported results presented at a scientific meeting. Twenty-one percent of releases were not explicit about the source of original data. While harms or adverse events were commonly cited (76%), study limitations were rarely noted (6%). Almost one-third (29%) of releases did not quantify study results. Studies presented in abstract form were subsequently published within at least 20 months in 53 % of cases. Conclusions: Pharmaceutical company press releases frequently report basic study details. However, readers should be cautioned by the preliminary nature of the data and lack of identified limitations. Methods to improve the reporting and interpretation of drug company press releases are desirable to prevent misleading media coverage

    Egg Laying Decisions in Drosophila Are Consistent with Foraging Costs of Larval Progeny

    Get PDF
    Decision-making is defined as selection amongst options based on their utility, in a flexible and context-dependent manner. Oviposition site selection by the female fly, Drosophila melanogaster, has been suggested to be a simple and genetically tractable model for understanding the biological mechanisms that implement decisions [1]. Paradoxically, female Drosophila have been found to avoid oviposition on sugar which contrasts with known Drosophila feeding preferences [1]. Here we demonstrate that female Drosophila prefer egg laying on sugar, but this preference is sensitive to the size of the egg laying substrate. With larger experimental substrates, females preferred to lay eggs directly on sugar containing media over other (plain, bitter or salty) media. This was in contrast to smaller substrates with closely spaced choices where females preferred non-sweetened media. We show that in small egg laying chambers newly hatched first instar larvae are able to migrate along a diffusion gradient to the sugar side. In contrast, in contexts where females preferred egg laying directly on sugar, larvae were unable to migrate to find the sucrose if released on the sugar free side of the chamber. Thus, where larval foraging costs are high, female Drosophila choose to lay their eggs directly upon the nutritious sugar substrate. Our results offer a powerful model for female decision-making

    Manual engagement and automation in amateur photography

    Full text link
    © 2017, © The Author(s) 2017. Automation has been central to the development of modern photography and, in the age of digital and smartphone photography, now largely defines everyday experience of the photographic process. In this article, we question the acceptance of automation as the default position for photography, arguing that discussions of automation need to move beyond binary concerns of whether to automate or not and, instead, to consider what is being automated and the degree of automation couched within the particularities of people’s practices. We base this upon findings from ethnographic fieldwork with people engaging manually with film-based photography. While automation liberates people from having to interact with various processes of photography, participants in our study reported a greater sense of control, richer experiences and opportunities for experimentation when they were able to engage manually with photographic processes

    Systematic review of antiepileptic drugs’ safety and effectiveness in feline epilepsy

    Get PDF
    Understanding the efficacy and safety profile of antiepileptic drugs (AEDs) in feline epilepsy is a crucial consideration for managing this important brain disease. However, there is a lack of information about the treatment of feline epilepsy and therefore a systematic review was constructed to assess current evidence for the AEDs’ efficacy and tolerability in cats. The methods and materials of our former systematic reviews in canine epilepsy were mostly mirrored for the current systematic review in cats. Databases of PubMed, CAB Direct and Google scholar were searched to detect peer-reviewed studies reporting efficacy and/or adverse effects of AEDs in cats. The studies were assessed with regards to their quality of evidence, i.e. study design, study population, diagnostic criteria and overall risk of bias and the outcome measures reported, i.e. prevalence and 95% confidence interval of the successful and affected population in each study and in total

    The Epidemiology of Lead Toxicity in Adults: Measuring Dose and Consideration of Other Methodologic Issues

    Get PDF
    We review several issues of broad relevance to the interpretation of epidemiologic evidence concerning the toxicity of lead in adults, particularly regarding cognitive function and the cardiovascular system, which are the subjects of two systematic reviews that are also part of this mini-monograph. Chief among the recent developments in methodologic advances has been the refinement of concepts and methods for measuring individual lead dose in terms of appreciating distinctions between recent versus cumulative doses and the use of biological markers to measure these parameters in epidemiologic studies of chronic disease. Attention is focused particularly on bone lead levels measured by K-shell X-ray fluorescence as a relatively new biological marker of cumulative dose that has been used in many recent epidemiologic studies to generate insights into lead’s impact on cognition and risk of hypertension, as well as the alternative method of estimating cumulative dose using available repeated measures of blood lead to calculate an individual’s cumulative blood lead index. We review the relevance and interpretation of these lead biomarkers in the context of the toxico-kinetics of lead. In addition, we also discuss methodologic challenges that arise in studies of occupationally and environmentally exposed subjects and those concerning race/ethnicity and socioeconomic status and other important covariates

    Artificial intelligence in cancer imaging: Clinical challenges and applications

    Get PDF
    Judgement, as one of the core tenets of medicine, relies upon the integration of multilayered data with nuanced decision making. Cancer offers a unique context for medical decisions given not only its variegated forms with evolution of disease but also the need to take into account the individual condition of patients, their ability to receive treatment, and their responses to treatment. Challenges remain in the accurate detection, characterization, and monitoring of cancers despite improved technologies. Radiographic assessment of disease most commonly relies upon visual evaluations, the interpretations of which may be augmented by advanced computational analyses. In particular, artificial intelligence (AI) promises to make great strides in the qualitative interpretation of cancer imaging by expert clinicians, including volumetric delineation of tumors over time, extrapolation of the tumor genotype and biological course from its radiographic phenotype, prediction of clinical outcome, and assessment of the impact of disease and treatment on adjacent organs. AI may automate processes in the initial interpretation of images and shift the clinical workflow of radiographic detection, management decisions on whether or not to administer an intervention, and subsequent observation to a yet to be envisioned paradigm. Here, the authors review the current state of AI as applied to medical imaging of cancer and describe advances in 4 tumor types (lung, brain, breast, and prostate) to illustrate how common clinical problems are being addressed. Although most studies evaluating AI applications in oncology to date have not been vigorously validated for reproducibility and generalizability, the results do highlight increasingly concerted efforts in pushing AI technology to clinical use and to impact future directions in cancer care

    Professionalism and Evolving Concepts of Quality

    Get PDF
    For much of the twentieth century, quality of care was defined specifically in terms of physician characteristics and behaviors. High-quality physicians were well trained, knowledgeable, skillful, and compassionate. More recently, quality of care has been defined in terms of systems of care. High-quality organizations develop and adopt practices to reduce adverse events and optimize outcomes. This essay discusses this transformation from physician-based to organization-based concepts of quality and the consequences for patient care and medical professionalism
    corecore