39 research outputs found

    Ongoing Geometric Remodeling of the Parent Artery After Flow-Diverter Stent Reconstruction in Cerebral Aneurysms: The Device Design Matters

    Get PDF
    Objective Configuration changes of the parent artery (PA) after flow-diverter (FD) stent reconstruction, caused by the bending force of the device, may have an additional role in aneurysm occlusion as a result of the secondary alteration of intra-aneurysmal hemodynamics related to the geometry alteration of the vessel. To determine the degree of PA deformation and aneurysm occlusion rates after deployment of 2 different types of FD. Methods Patients treated with 2 different designs of cobalt-chromium braid (48 and 64 wire braid) structure FD were subject to analysis. Vascular angle changes at the level of the reconstructed segment immediately after FD deployment and at 1 year follow-up were measured and the potential relationship with aneurysmal occlusion rate was analyzed. Results Forty-two patients harboring 48 aneurysms were included in the present study. The aneurysms were divided into side wall (85.4%) and bifurcation types (14.6%). Twenty-six aneurysms were treated using the Pipeline FD (48 wire braid; 54.2%) and 22 using the Evolve FD (64 wire braid; 45.8%). Of the 48 aneurysms, 42 (87.5%) met the primary end point of complete occlusion at 12 months. The median postdeployment angle change was 7.04°± 4.59° for the Pipeline and 5.05°± 2.49° for the Evolve, whereas the median 12 months follow-up angle change was 15.49°± 10.99° and 10.01°± 8.83°, respectively. PA angle changes were significantly higher in the bifurcation group compared with the side wall group both during procedure and at 12 months follow-up. Angle change had a statistically nonsignificant association with complete aneurysm occlusion. Conclusions PA deformation starts immediately after deployment and remodeling continues for 1 year after. Aneurysms located in the vessel bifurcation were more prone to PA straightening after FD deployment than were side wall aneurysms. Furthermore, Pipeline seemed to be more prone to inducing vascular deformation, compared with Evolve

    Single antiplatelet regimen in flow diverter treatment of cerebral aneurysms: The drug matters. A systematic review and meta-analysis

    Get PDF
    BACKGROUND Hemorrhagic and thromboembolic complications (TECs) are the main concerns in the endovascular treatment of intracranial aneurysms using flow diverter devices (FDs). The clinical demand for single antiplatelet therapy (SAPT) is increasing especially with the development of devices with lower thrombogenicity profile. However, the safety of SAPT is not well established. OBJECTIVE To analyze the safety and efficacy of SAPT in terms of ischemic and hemorrhagic complications in patients undergoing FDs treatment for cerebral aneurysms. METHODS A systematic literature search and meta-analysis were conducted in PubMed, Ovid MEDLINE, Ovid Embase, and Web of Science from January 2010 until October 2022. Twelve articles which reported SAPT and data on hemorrhagic, TECs, and mortality following FDs treatment were included. RESULTS Overall, the 12 studies involved 237 patients with 295 aneurysms. Five investigated the safety and efficacy of SAPT in 202 unruptured aneurysms. Six studies focused on 57 ruptured aneurysms. One study included both ruptured and unruptured aneurysms. Among the 237 patients, prasugrel was most often used as SAPT in 168 cases (70.9%), followed by aspirin in 42 (17.7%) patients, and by ticagrelor in 27 (11.4%). Overall, the hemorrhagic complication rate was 0.1% (95% CI 0% to 1.8%). The TEC rate was 7.6% (95% CI 1.7% to 16.1%). In the subgroup analysis, the TEC rates of prasugrel monotherapy of 2.4% (95% CI 0% to 9.3%) and ticagrelor monotherapy of 4.2% (95% CI 0.1% to 21.1%) were lower than of aspirin monotherapy 20.2% (95% CI 5.9% to 38.6%). The overall mortality rate was 1.3% (95% CI 0% to 6.1%). CONCLUSION According to the available data, SAPT regimen in patients undergoing FDs treatment for cerebral aneurysms has an acceptable safety profile, especially with the use of ADP-receptor antagonists

    Diagnóstico, tratamento e seguimento do carcinoma medular de tireoide: recomendações do Departamento de Tireoide da Sociedade Brasileira de Endocrinologia e Metabologia

    Full text link

    Excess cerebral TNF causing glutamate excitotoxicity rationalizes treatment of neurodegenerative diseases and neurogenic pain by anti-TNF agents

    Full text link