17 research outputs found

    Continuous wave optical parametric oscillator for quartz-enhanced photoacoustic trace gas sensing

    Get PDF
    A continuous wave optical parametric oscillator, generating up to 300 mW idler output in the 3–4 μm wavelength region, and pumped by a fiber-amplified DBR diode laser is used for trace gas detection by means of quartz-enhanced photoacoustic spectroscopy (QEPAS). Mode-hop-free tuning of the OPO output over 5.2 cm-1 and continuous spectral coverage exceeding 16.5 cm-1 were achieved via electronic pump source tuning alone. Online monitoring of the idler wavelength, with feedback to the DBR diode laser, provided an automated closed-loop control allowing arbitrary idler wavelength selection within the pump tuning range and locking of the idler wavelength with a stability of 1.7×10-3 cm-1 over at least 30 min.\ud \ud Using this approach, we locked the idler wavelength at an ethane absorption peak and obtained QEPAS data to verify the linear response of the QEPAS signal at different ethane concentrations (100 ppbv-20 ppmv) and different power levels. The detection limit for ethane was determined to be 13 ppbv (20 s averaging), corresponding to a normalized noise equivalent absorption coefficient of 4.4×10-7 cm-1  W/Hz1/2

    Small-Size Resonant Photoacoustic Cell of Inclined Geometry for Gas Detection

    Full text link
    A photoacoustic cell intended for laser detection of trace gases is represented. The cell is adapted so as to enhance the gas-detection performance and, simultaneously, to reduce the cell size. The cell design provides an efficient cancellation of the window background (a parasite response due to absorption of laser beam in the cell windows) and acoustic isolation from the environment for an acoustic resonance of the cell. The useful photoacoustic response from a detected gas, window background and noise are analyzed in demonstration experiments as functions of the modulation frequency for a prototype cell with the internal volume ~ 0.5 cm^3. The minimal detectable absorption for the prototype is estimated to be ~ 1.2 10^{-8} cm^{-1} W Hz^{-1/2}.Comment: 11 pages, 5 figure

    Continuous-wave optical parametric oscillator for trace gas detection in life sciences

    Get PDF
    Contains fulltext : 60686.pdf (publisher's version ) (Open Access)RU Radboud Universiteit Nijmegen, 4 februari 2004Promotor : Parker, D.H. Co-promotores : Harren, F.J.M., Bisson, S.E.XII, 119 p

    Continuous-wave operation of a single-frequency optical parametric oscillator at 4-5 mu m based on periodically poled LiNbO3

    Get PDF
    Contains fulltext : 100905.pdf (publisher's version ) (Open Access

    Combined wide pump tuning and high power of a continuous-wave, singly resonant optical parametric oscillator

    No full text
    Contains fulltext : 60225pub.pdf (publisher's version ) (Closed access)A new singly resonant, single-frequency optical parametric oscillator (OPO) has been developed for the 2.6-4.7 mum infrared wavelength region, using a high power (>20 W), widely tunable (1024-1034 nm) Yb:YAG pump source. With the OPO frequency stabilized with an intracavity etalon, the OPO achieved an idler output power of 3 W at 2.954 mum. Tuning of the idler frequency was achieved by longitudinal mode-hop tuning of the pump source (FSR 100 MHz). In this way an idler frequency scan of 100-150 GHz could be obtained, after which the signal frequency hops ahead over the FSR of the intracavity etalon of the OPO (207 GHz). Due to un-optimized mirror coatings for the OPO cavity and PPLN crystal, the frequency stability was limited to 90 MHz over 1 s, with an unaffected long-term frequency stability of 250 MHz over 200 seconds

    Photoacoustic spectroscopy using continuouys wave optical parametric oscillators

    No full text
    Contains fulltext : 71923.pdf (publisher's version ) (Closed access

    Photoacoustic Spectroscopy using continuous wave Optical Parametric Oscillators

    No full text
    Contains fulltext : 36313pub.pdf (publisher's version ) (Closed access)511 p

    Optical parametric oscillator-based photoacoustic detection of CO 2 at 4.23 µm allows real-time monitoring of the respiration of small insects

    No full text
    A continuous wave, single frequency and continuously tunable optical parametric oscillator is used in combination with photoacoustic spectroscopy to detect trace emissions of CO2 from insects under atmospheric conditions. The optical parametric oscillator (OPO) contains a periodically poled lithium niobate crystal and is tunable over the 3.9 to 4.8 ¿m infrared wavelength region. With the strong rotational-vibrational absorption band of CO2 at 4.23 ¿m, it is possible to detect CO2 down to 7 parts per billion volume using 20 mW of the OPO beam. This detection sensitivity was achieved by adding 4% of SF6 gas to the atmospheric gas mixture to overcome the slow vibrational relaxation of the excited CO2 levels. The usefulness of this system is demonstrated by real-time measuring of the fluctuations of the CO2 concentration in the breath of a single ant (Lasius niger) and individual fruit flies (Drosophila melanogaster)

    Automatically tunable continuous-wave optical parametric oscillator for high-resolution spectroscopy and sensitive trace-gas detection

    No full text
    Contains fulltext : 36062pub.pdf (publisher's version ) (Closed access)We present a high-power (2.75 W), broadly tunable (2.75-3.83 mu m) continuous-wave optical parametric oscillator based on MgO-doped periodically poled lithium niobate. Automated tuning of the pump laser, etalon and crystal temperature results in a continuous wavelength coverage up to 450 cm(-1) per poling period at < 5x10(-4) cm(-1)upercript stop resolution. The versatility of the optical parametric oscillator as a coherent light source in trace-gas detection is demonstrated with photoacoustic and cavity ring-down spectroscopy. A 17-cm(-1)-wide CO2 spectrum at 2.8 mu m and multi-component gas mixtures of methane, ethane and water in human breath were measured using photoacoustics. Methane (at 3.2 mu m) and ethane (at 3.3 mu m) were detected using cavity ring-down spectroscopy with detection limits of 0.16 and 0.07 parts per billion by volume, respectively. A recording of (CH4)-C-12 and (CH4)-C-13 isotopes of methane shows the ability to detect both species simultaneously at similar sensitivities
    corecore