42 research outputs found

    Quadriceps volumes are reduced in people with patellofemoral joint osteoarthritis

    Get PDF
    Objectives: This study aimed to (1) compare the volumes of vastus medialis (VM), vastus lateralis (VL), vastus intermedius and rectus femoris and the ratio of VM/VL volumes between asymptomatic controls and patellofemoral joint osteoarthritis (PFJ OA) participants; and (2) assess the relationships between cross-sectional area (CSA) and volumes of the VM and VL in individuals with and without PFJ OA. Methods: Twenty-two participants with PFJ OA and 11 controls aged ≥40 years were recruited from the community and practitioner referrals. Muscle volumes of individual quadriceps components were measured from thigh magnetic resonance (MR) images. The CSA of the VM and lateralis were measured at 10 equally distributed levels (femoral condyles to lesser femoral trochanter). Results: PFJ OA individuals had smaller normalized VM (mean difference 0.90 cm ·kg , α = 0.011), VL (1.50 cm ·kg , α = 0.012) and rectus femoris (0.71 cm ·kg , α = 0.009) volumes than controls. No differences in the VM/VL ratio were observed. The CSA at the third level (controls) and fourth level (PFJ OA) above the femoral condyles best predicted VM volume, whereas the VL volume was best predicted by the CSA at the seventh level (controls) and sixth level (PFJ OA) above the femoral condyles. Conclusion: Reduced quadriceps muscle volume was a feature of PFJ OA. Muscle volume could be predicted from CSA measurements at specific levels in PFJ OA patients and controls

    Modeling of the condyle elements within a biomechanical knee model

    Get PDF
    The development of a computational multibody knee model able to capture some of the fundamental properties of the human knee articulation is presented. This desideratum is reached by including the kinetics of the real knee articulation. The research question is whether an accurate modeling of the condyle contact in the knee will lead to reproduction of the complex combination of flexion/extension, abduction/adduction and tibial rotation ob-served in the real knee? The model is composed by two anatomic segments, the tibia and the femur, whose characteristics are functions of the geometric and anatomic properties of the real bones. The biomechanical model characterization is developed under the framework of multibody systems methodologies using Cartesian coordinates. The type of approach used in the proposed knee model is the joint surface contact conditions between ellipsoids, represent-ing the two femoral condyles, and points, representing the tibial plateau and the menisci. These elements are closely fitted to the actual knee geometry. This task is undertaken by con-sidering a parameter optimization process to replicate experimental data published in the lit-erature, namely that by Lafortune and his co-workers in 1992. Then, kinematic data in the form of flexion/extension patterns are imposed on the model corresponding to the stance phase of the human gait. From the results obtained, by performing several computational simulations, it can be observed that the knee model approximates the average secondary mo-tion patterns observed in the literature. Because the literature reports considerable inter-individual differences in the secondary motion patterns, the knee model presented here is also used to check whether it is possible to reproduce the observed differences with reasonable variations of bone shape parameters. This task is accomplished by a parameter study, in which the main variables that define the geometry of condyles are taken into account. It was observed that the data reveal a difference in secondary kinematics of the knee in flexion ver-sus extension. The likely explanation for this fact is the elastic component of the secondary motions created by the combination of joint forces and soft tissue deformations. The proposed knee model is, therefore, used to investigate whether this observed behavior can be explained by reasonable elastic deformations of the points representing the menisci in the model.Fundação para a Ciência e a Tecnologia (FCT) - PROPAFE – Design and Development of a Patello-Femoral Prosthesis (PTDC/EME-PME/67687/2006), DACHOR - Multibody Dynamics and Control of Hybrid Active Orthoses MIT-Pt/BSHHMS/0042/2008, BIOJOINTS - Development of advanced biological joint models for human locomotion biomechanics (PTDC/EME-PME/099764/2008)

    Mechanical properties of normal and osteoarthritic human articular cartilage

    Get PDF
    Available online 23 January 2016Abstract not availableDale L. Robinson, Mariana E. Kersh, Nicole C. Walsh, David C. Ackland, Richard N. deSteiger, Marcus G.Pand

    A non-invasive, 3D, dynamic MRI method for measuring muscle moment arms in vivo : demonstration in the human ankle joint and Achilles tendon

    No full text
    Muscle moment arms are used widely in biomechanical analyses. Often they are measured in 2D or at a series of static joint positions. In the present study we demonstrate a simple MRI method for measuring muscle moment arms dynamically in 3D from a single range-of-motion cycle. We demonstrate this method in the Achilles tendon for comparison with other methods, and validate the method using a custom apparatus. The method involves registration of high-resolution joint geometry from MRI scans of the stationary joint with low-resolution geometries from ultrafast MRI scans of the slowly moving joint. Tibio-talar helical axes and 3D Achilles tendon moment arms were calculated throughout passive rotation for 10 adult subjects, and compared with recently published data. A simple validation was conducted by comparing MRI measurements with direct physical measurements made on a phantom. The moment arms measured using our method and others were similar and there was good agreement between physical measurements (mean 41.0 mm) and MRI measurements (mean 42.6 mm) made on the phantom. This new method can accurately measure muscle moment arms from a single range-of-motion cycle without the need to control rotation rate or gate the scanning. Supplementary data includes custom software to assist implementation.Applied Science, Faculty ofMedicine, Faculty ofNon UBCMechanical Engineering, Department ofOrthopaedic Surgery, Department ofReviewedFacultyResearcherGraduat

    Vertical jumping performance of bonobo (Pan paniscus) suggests superior muscle properties

    Get PDF
    Vertical jumping was used to assess muscle mechanical output in bonobos and comparisons were drawn to human jumping. Jump height, defined as the vertical displacement of the body centre of mass during the airborne phase, was determined for three bonobos of varying age and sex. All bonobos reached jump heights above 0.7 m, which greatly exceeds typical human maximal performance (0.3–0.4 m). Jumps by one male bonobo (34 kg) and one human male (61.5 kg) were analysed using an inverse dynamics approach. Despite the difference in size, the mechanical output delivered by the bonobo and the human jumper during the push-off was similar: about 450 J, with a peak power output close to 3000 W. In the bonobo, most of the mechanical output was generated at the hips. To account for the mechanical output, the muscles actuating the bonobo's hips (directly and indirectly) must deliver muscle-mass-specific power and work output of 615 W kg(−1) and 92 J kg(−1), respectively. This was twice the output expected on the basis of muscle mass specific work and power in other jumping animals but seems physiologically possible. We suggest that the difference is due to a higher specific force (force per unit of cross-sectional area) in the bonobo
    corecore