598 research outputs found
Serum IL-17 after one course of sublingual immunotherapy in allergic rhinitis to birch
Recently, it has been reported that IL-17 may be involved in allergic reaction. Sublingual immunotherapy (SLIT) is the unique curative treatment for allergic rhinitis. This study aims at investigating whether one course of birch SLIT could affect serum IL-17 levels. The findings provided show that some IL-17 producer patients had a reduction of serum IL-17 levels after one SLIT course. Therefore, this preliminary study shows that a single pre-seasonal SLIT course may induce a significant decreasing trend in serum IL-17 levels; further study should be carried out to define the role exerted by IL-17 in allergic rhinitis
Flux dynamics in NdO1-xFxFeAs bulk sample
We present data of multi harmonic magneto-dynamic experiments. In particular,
we performed ac magnetic susceptibility experiments on layered pnictide-oxide
quaternary compound NdOFeAs doped with fluorine. The experiments allow measure
the critical temperature and probe the flux dynamic behavior using the third
harmonic component of the ac susceptibility of a NdF0.16FeAsO0.84 bulk sample
as a function of temperature and frequency of the applied ac magnetic fields.
Measured signals are connected with the non-linear superconducting flux dynamic
behavior and are characterized by a flux critical states sustaining a
superconducting critical current. In this framework the irreversibility line
that describes the stable superconducting state has been extracted from the
onset of the third harmonic signal vs. frequency. Finally we present also the
analysis of the flux dynamic dimensionality in the investigated sample.Comment: 10 pages, 5 figure
Evidence for Irradiation Triggered Nonuniform Defect Distribution In Multiharmonic Magnetic Susceptibility of Neutron Irradiated YBa2Cu3O7-x
Multiharmonic ac-magnetic susceptibility \ch11,\chi2,chi3, of neutron
irradiated Li-doped YBa2Cu3O7-x has revealed a nonmonotonic dependence of all
harmonics on the neutron fluence. The irradiation has a strongly depressive
influence on the intergrain connection suggesting an increase of the effective
thickness of the intergranular Josephson junction at aneutron fluence of
0.98x10 cm. Less damaged are the intragrain properties. A
spectacular enhancement of the superconducting intragranular properties
reflected in the characteristics of all harmonics was observed at highest
fluence \Phi = 9.98x10 cm. We assume that this effect results
from the development of a space inhomogeneous distribution with alternating
defectless and defect rich regions.Comment: 24 pages, 9 figures, accepted to J. Supercon
Effect of the compound L-mimosine in an in vivo model of chronic granuloma formation induced by potassium permanganate (KMNO4).
The plant amino acid L-mimosine has recently been suggested to inhibit cells at a regulatory step in late G phase before establishment of active DNA replication forks. In addition, L-mimosine is an extremely effective inhibitor of DNA replication in chromosomes of mammalian nuclei. In this work, the effect of L-mimosine on chronic inflammation induced by dorsal injections of 0.2 ml of a 1:40 saturated crystal solution of potassium permanganate in mice, was studied. Seven days afterwards, all mice developed a subcutaneous granulomatous tissue indicative of chronic inflammatory response at the site of infection. The intraperitoneal administration of L-mimosine (200 μg/dose) to the potassium permanganate treated mice for 5 consecutive days (the first at the same time of inoculation of the KMnO4), produced a significant decrease in size and weight of the granuloma when compared to mice not treated with L-mimosine (controls). In addition, in all mice treated with L-mimosine, there was a strong inhibition of tumor necrosis factor alpha that was revealed in the serum (P<0.05) and in the minced granulomas. Interleukin-6 was not detected in the serum of treated and untreated mice. These findings show for the first time, that L-mimosine may have an anti-inflammatory effect on chronic inflammation and an inhibitory effect on tumor necrosis factor alpha and interleukin-6 generation in supernatant fluids of minced granulomas
The cryogenic magneto-optical device for terahertz radiation detection
We present here a small-scale liquid Helium (LHe) immersion cryostat with an innovative optical setup suitable to work in long wavelength radiation ranges and under applied magnetic field. The cryostat is a multi stage device with several shielding in addition to several optical stages. The system has been designed with an external liquid Nitrogen boiler to reduce the liquid bubbling. The optical and mechanical properties of the optical elements were calculated and optimized for the designed configuration while the optical layout has been simulated and optimized among different configurations based on the geometry of the device. The final design has been optimized for low noise radiation measurements of proximity junction arrays under applied magnetic field in the wavelength range λ=250-2500 µm
A cryogenic magneto-optical device for long wavelength radiation
We present here a small-scale liquid helium immersion cryostat with an innovative optical setup suitable to work in long wavelength radiation ranges and under an applied magnetic field. The cryostat is a multi-stage device with several shielding in addition to several optical stages. The system has been designed with an external liquid nitrogen boiler to reduce liquid bubbling. The optical and mechanical properties of the optical elements were calculated and optimized for the designed configuration, while the optical layout has been simulated and optimized among different configurations based on the geometry of the device. The final design has been optimized for low-noise radiation measurements of proximity junction arrays under an applied magnetic field in the wavelength range λ = 250 μm-2500 μm
Study of coupling loss on bi-columnar BSCCO/Ag tapes by a.c. susceptibility measurements
Coupling losses were studied in composite tapes containing superconducting
material in the form of two separate stacks of densely packed filaments
embedded in a metallic matrix of Ag or Ag alloy. This kind of sample geometry
is quite favorable for studying the coupling currents and in particular the
role of superconducting bridges between filaments. By using a.c. susceptibility
technique, the electromagnetic losses as function of a.c. magnetic field
amplitude and frequency were measured at the temperature T = 77 K for two tapes
with different matrix composition. The length of samples was varied by
subsequent cutting in order to investigate its influence on the dynamics of
magnetic flux penetration. The geometrical factor which takes into
account the demagnetizing effects was established from a.c. susceptibility data
at low amplitudes. Losses vs frequency dependencies have been found to agree
nicely with the theoretical model developed for round multifilamentary wires.
Applying this model, the effective resistivity of the matrix was determined for
each tape, by using only measured quantities. For the tape with pure silver
matrix its value was found to be larger than what predicted by the theory for
given metal resistivity and filamentary architecture. On the contrary, in the
sample with a Ag/Mg alloy matrix, an effective resistivity much lower than
expected was determined. We explain these discrepancies by taking into account
the properties of the electrical contact of the interface between the
superconducting filaments and the normal matrix. In the case of soft matrix of
pure Ag, this is of poor quality, while the properties of alloy matrix seem to
provoke an extensive creation of intergrowths which can be actually observed in
this kind of samples.Comment: 20 pages 11 figure, submitted to Superconductor Science and
Technolog
Thyroid cancer diagnosis by Raman spectroscopy
Over the last 50 years, the incidence of human thyroid cancer disease has seen a significative increment. This comes along with an even higher increment of surgery, since, according to the international guidelines, patients are sometimes addressed to surgery also when the fine needle aspiration gives undetermined cytological diagnosis. As a matter of fact, only 30% of the thyroid glands removed for diagnostic purpose have a post surgical histological report of malignancy: this implies that about 70% of the patients have suffered an unnecessary thyroid removal. Here we show that Raman spectroscopy investigation of thyroid tissues provides reliable cancer diagnosis. Healthy tissues are consistently distinguished from cancerous ones with an accuracy of ∼ 90%, and the three cancer typology with highest incidence are clearly identified. More importantly, Raman investigation has evidenced alterations suggesting an early stage of transition of adenoma tissues into cancerous ones. These results suggest that Raman spectroscopy may overcome the limits of current diagnostic tools
- …