421 research outputs found

    Connectivity of Phases and Growth Mechanisms in Peritectic Alloys Solidified at Low Speed: an X-Ray Tomography Study of Cu-Sn

    Get PDF
    The variety of microstructures that form at low solidification speed in peritectic alloys, bands, and islands, or even coupled (or cooperative) growth of the primary α and peritectic β phases, have been previously explained by nucleation-growth mechanisms. In a recent investigation on Cu-Sn, a new growth mechanism was conjectured on the basis of two-dimensional (2-D) optical microscopy and electron backscattered diffraction (EBSD) observations made in longitudinal sections. In the present contribution, synchrotron-based tomographic microscopy has been used to confirm this mechanism: α and β phases totally interconnected in three dimensions and bands (or islands) can result from an overlay mechanism, rather than from a nucleation events sequence. When the lateral growth of a new layer is too fast, an instability can lead to the formation of a lamellar structure as for eutectic alloy

    Synchrotron x-ray μ-tomography to model the thermal radiative properties of an opaque ceramic coating at T: 1000 K

    Get PDF
    Synchrotron x-ray μ-tomography has been used to reconstruct the three-dimensional view of a rough surface extracted from a heterogeneous ceramic coating composed of Pr2NiO4+δ. Radiographs with a resolution of 0.7 μm have been recorded at T = 300, 600, and 900 K. The analysis of surface geometry makes use of the geometrical optic approximation up to T = 900 K possible. Subsequently, a large number of rays (105) are impinged onto the numerical surface, as revealed by x-ray tomography, to reproduce the normal emissivity of the coating. This normal emissivity was obtained beforehand by infrared emittance spectroscopy at T = 1000 K. Comparison of the two approaches suggests that the optical contribution of the coating micropores can be integrated into the ray tracing code. The effective medium approximation is used for this purpose. Finally, the applicability of this hybrid approach is discusse

    Xray Tomographic Microscopic Studies a Resin Embedded Paint Sample from a Mechanical Failing Area in the Floor Tiles of The Art of Painting by Johannes Vermeer (1632-1675)

    Get PDF
    Extended abstract of a paper presented at Microscopy and Microanalysis 2010 in Portland, Oregon, USA, August 1 - August 5, 201

    Quantitative aspects of the microvascular system in macaque visual cortex

    No full text
    The basic principle of the most frequently used functional neuroimaging methods is the brain’s local dynamic regulation of blood flow. For a correct interpretation of neuroimaging results the structural and functional neurovascular coupling underlying this regulation must be well understood. Here we report quantitative anatomical data of the microvasculature in the macaque visual cortex. Formalin-fixed frozen sections of 4 animals (M. mulatta) were processed for double fluorescence immunohistochemistry. Sections were incubated with anti-collagen type IV and DAPI to stain for vessels and cell nuclei. In one additional animal, the anti-collagen procedure was combined with cytochrome oxidase staining in V1. The length density (LD), surface density (SD), volume fraction (VF) and diameter (D) of the vessels were stereologically determined. Furthermore, synchrotron-based computed tomographies (SRCT) of formalin-fixed and barium sulfate-perfused brain samples from another 2 animals were used to corroborate the histological results. In V1, the vascular density was highest in layer IVc- (LD 674.7 mm/mm3, SD 15.2 mm2/mm3, VF 2.6 , D 7.2 microns) and lowest in layer I (LD 461.5 mm/mm3, SD 10.9 mm2/mm3, VF 1.9 , D 7.5 microns). In all extrastriate visual areas analyzed (V2, V3, V4, V5), the vascular density was generally lower, and the difference between layer IV and the remaining layers was less prominent when compared to V1. These density values were similar compared to the ones tomographically obtained from SRCT. The vascular density in cytochrome oxidase rich blobs in V1 was 14 higher as compared to the interblob region. In summary, V1 is different from all extrastriate areas analyzed with respect to the laminar vessel distribution and overall vascular density. Differences between extrastriate areas were negligible. The overall vascular volume fraction in visual cortex derived from immunostaining was approximately 2 , a value that was well reproduced by the SRCT

    Regridding reconstruction algorithm for real-time tomographic imaging

    Get PDF
    Sub-second temporal-resolution tomographic microscopy is becoming a reality at third-generation synchrotron sources. Efficient data handling and post-processing is, however, difficult when the data rates are close to 10 GB s-1. This bottleneck still hinders exploitation of the full potential inherent in the ultrafast acquisition speed. In this paper the fast reconstruction algorithm gridrec, highly optimized for conventional CPU technology, is presented. It is shown that gridrec is a valuable alternative to standard filtered back-projection routines, despite being based on the Fourier transform method. In fact, the regridding procedure used for resampling the Fourier space from polar to Cartesian coordinates couples excellent performance with negligible accuracy degradation. The stronger dependence of the observed signal-to-noise ratio for gridrec reconstructions on the number of angular views makes the presented algorithm even superior to filtered back-projection when the tomographic problem is well sampled. Gridrec not only guarantees high-quality results but it provides up to 20-fold performance increase, making real-time monitoring of the sub-second acquisition process a reality

    Local strain distribution in real three-dimensional alveolar geometries

    Get PDF
    Mechanical ventilation is not only a life saving treatment but can also cause negative side effects. One of the main complications is inflammation caused by overstretching of the alveolar tissue. Previously, studies investigated either global strains or looked into which states lead to inflammatory reactions in cell cultures. However, the connection between the global deformation, of a tissue strip or the whole organ, and the strains reaching the single cells lining the alveolar walls is unknown and respective studies are still missing. The main reason for this is most likely the complex, sponge-like alveolar geometry, whose three-dimensional details have been unknown until recently. Utilizing synchrotron-based X-ray tomographic microscopy, we were able to generate real and detailed three-dimensional alveolar geometries on which we have performed finite-element simulations. This allowed us to determine, for the first time, a three-dimensional strain state within the alveolar wall. Briefly, precision-cut lung slices, prepared from isolated rat lungs, were scanned and segmented to provide a three-dimensional geometry. This was then discretized using newly developed tetrahedral elements. The main conclusions of this study are that the local strain in the alveolar wall can reach a multiple of the value of the global strain, for our simulations up to four times as high and that thin structures obviously cause hotspots that are especially at risk of overstretching

    Visualization of respiratory flows from 3D reconstructed alveolar airspaces using X-ray tomographic microscopy

    Get PDF
    A deeper knowledge of the three-dimensional (3D) structure of the pulmonary acinus has direct applications in studies on acinar fluid dynamics and aerosol kinematics. To date, however, acinar flow simulations have been often based on geometrical models inspired by morphometrical studies; limitations in the spatial resolution of lung imaging techniques have prevented the simulation of acinar flows using 3D reconstructions of such small structures. In the present study, we use high-resolution, synchrotron radiation-based X-ray tomographic microscopy (SRXTM) images of the pulmonary acinus of a mouse to reconstruct 3D alveolar airspaces and conduct computational fluid dynamic (CFD) simulations mimicking rhythmic breathing motion. Respiratory airflows and Lagrangian (massless) particle tracking are visualized in two examples of acinar geometries with varying size and complexity, representative of terminal sacculi including their alveoli. The present CFD simulations open the path towards future acinar flow and aerosol deposition studies in complete and anatomically realistic multi-generation acinar trees using reconstructed 3D SRXTM geometries

    A tilted grating interferometer for full vector field differential x-ray phase contrast tomography

    Full text link
    We report on a setup for differential x-ray phase-contrast imaging and tomography, that measures the full 2D phase-gradient information. The setup uses a simple one-dimensional x-ray grating interferometer, in which the grating structures of the interferometer are oriented at a tilt angle with respect to the sample rotation axis. In such a configuration, the differential phase images from opposing tomography projections can be combined to yield both components of the gradient vector. We show how the refractive index distribution as well as its x, y, and z gradient components can be reconstructed directly from the recorded projection data. The method can equally well be applied at conventional x-ray tube sources, to analyzer based x-ray imaging or neutron imaging. It is demonstrated with measurements of an x-ray phantom and a rat brain using synchrotron radiation
    corecore