757 research outputs found

    Assessing the accuracy of quantum Monte Carlo and density functional theory for energetics of small water clusters

    Full text link
    We present a detailed study of the energetics of water clusters (H2_2O)n_n with n≤6n \le 6, comparing diffusion Monte Carlo (DMC) and approximate density functional theory (DFT) with well converged coupled-cluster benchmarks. We use the many-body decomposition of the total energy to classify the errors of DMC and DFT into 1-body, 2-body and beyond-2-body components. Using both equilibrium cluster configurations and thermal ensembles of configurations, we find DMC to be uniformly much more accurate than DFT, partly because some of the approximate functionals give poor 1-body distortion energies. Even when these are corrected, DFT remains considerably less accurate than DMC. When both 1- and 2-body errors of DFT are corrected, some functionals compete in accuracy with DMC; however, other functionals remain worse, showing that they suffer from significant beyond-2-body errors. Combining the evidence presented here with the recently demonstrated high accuracy of DMC for ice structures, we suggest how DMC can now be used to provide benchmarks for larger clusters and for bulk liquid water.Comment: 34 pages, 6 figure

    Continuum variational and diffusion quantum Monte Carlo calculations

    Full text link
    This topical review describes the methodology of continuum variational and diffusion quantum Monte Carlo calculations. These stochastic methods are based on many-body wave functions and are capable of achieving very high accuracy. The algorithms are intrinsically parallel and well-suited to petascale computers, and the computational cost scales as a polynomial of the number of particles. A guide to the systems and topics which have been investigated using these methods is given. The bulk of the article is devoted to an overview of the basic quantum Monte Carlo methods, the forms and optimisation of wave functions, performing calculations within periodic boundary conditions, using pseudopotentials, excited-state calculations, sources of calculational inaccuracy, and calculating energy differences and forces

    Novel Processing of Hydroxyapatite-Zirconia Composites using Nano-Sized Particles

    Get PDF
    A method to produce composites of hydroxyapatite (HA) with ZrO2 (Y-TZP) additions between 0 and 10 wt % at a low sinter temperature of 750 °C is presented. The method limits the amount of reaction between the HA and ZrO2. A ZrO2 loading level that would improve strength while limiting the decomposition of the HA is studied

    Investigation into the Ultrasound Setting of Glass Ionomer Cements. Part I. Postulated Modalities

    Get PDF
    Fuji IX glass is a low phosphate, low soda containing glass which has strontia incorporated as a radio-pacifier. This glass material was analyzed during exposure to different durations of ultrasound in an attempt to determine how the glass phase reacts. Cross sections of Fuji IX cement, set both conventionally and by ultrasound, were subsequently compared by microscopy. The resultant data were analyzed in detail

    Quantum Monte Carlo study of the Ne atom and the Ne+ ion

    Full text link
    We report all-electron and pseudopotential calculations of the ground-stateenergies of the neutral Ne atom and the Ne+ ion using the variational and diffusion quantum Monte Carlo (DMC) methods. We investigate different levels of Slater-Jastrow trial wave function: (i) using Hartree-Fock orbitals, (ii) using orbitals optimized within a Monte Carlo procedure in the presence of a Jastrow factor, and (iii) including backflow correlations in the wave function. Small reductions in the total energy are obtained by optimizing the orbitals, while more significant reductions are obtained by incorporating backflow correlations. We study the finite-time-step and fixed-node biases in the DMC energy and show that there is a strong tendency for these errors to cancel when the first ionization potential (IP) is calculated. DMC gives highly accurate values for the IP of Ne at all the levels of trial wave function that we have considered

    A CASE STUDY ON THE EFFECTS OF THE UPPER ARM DEFINITION ON SHOULDER AND ELBOW KINEMATICS DURING THE BADMINTON SMASH

    Get PDF
    The aim of this case study was to identify the effect of the upper arm definition on shoulder and elbow kinematics during the badminton smash. A method was proposed that corrects the false external rotation when using the shoulder-elbow-wrist plane based on the carrying angle (ISB-2C) and compared to ISB recommendations for defining the upper arm (ISB-1 and ISB-2). Differences were found in shoulder and elbow kinematics, in particular angular velocities. Both magnitude and the time history of the angular velocity were affected. In particular, use of the medial and lateral epicondyles was unable to detect a reasonable signal for pronation/supination. ISB-2C reduces some of the problems associated with ISB-1 and ISB-2 e.g. soft-tissue artifact, proximity of medial and lateral epicondyles to the humeral longitudinal axis and false external rotation caused by the carrying angle

    Aluminium-Free Glass Polyalkenoate Spinal Cements

    Get PDF
    Addition of Yitanium increased the Wt & St and the sf strength of these cements compared to the control (BT 101). © 2011 IEEE

    Degradable Borate Glass Polyalkenoate Cements

    Get PDF
    Glass polyalkenoate cements (GPCs) containing aluminum-free borate glasses having the general composition Ag2O-Na2O-CaO-SrO-ZnO- TiO2-B2O3 were evaluated in this work. An initial screening study of sixteen compositions was used to identify regions of glass formation and cement compositions with promising rheological properties. The results of the screening study were used to develop four model borate glass compositions for further study. A second round of rheological experiments was used to identify a preferred GPC formulation for each model glass composition. The model borate glasses containing higher levels of TiO2 (7.5 mol %) tended to have longer working times and shorter setting times. Dissolution behavior of the four model GPC formulations was evaluated by measuring ion release profiles as a function of time. All four GPC formulations showed evidence of incongruent dissolution behavior when considering the relative release profiles of sodium and boron, although the exact dissolution profile of the glass was presumably obscured by the polymeric cement matrix. Compression testing was undertaken to evaluate cement strength over time during immersion in water. The cements containing the borate glass with 7.5 mol % TiO2 had the highest initial compressive strength, ranging between 20 and 30 MPa. No beneficial aging effect was observed-instead, the strength of all four model GPC formulations was found to degrade with time. © 2014 Springer Science+Business Media

    Comparison of an Experimental Bone Cement with a Commercial Control, Hydroset™

    Get PDF
    Glass polyalkenoate cements based on strontium calcium zinc silicate glasses (Zn-GPCs) and high molecular weight polyacrylic acids (PAA) (MW; 52,000-210,000) have been shown to exhibit mechanical properties and in vitro bioactivity suitable for arthroplasty applications. Unfortunately, these formulations exhibit working times and setting times which are too short for invasive surgical applications such as bone void filling and fracture fixation. In this study, Zn-GPCs were formulated using a low molecular weight PAA (MW; 12,700) and a modifying agent, trisodium citrate dihydrate (TSC), with the aim of improving the rheological properties of Zn-GPCs. These novel formulations were then compared with commercial self-setting calcium phosphate cement, Hydroset™, in terms of compressive strength, biaxial flexural strength and Young\u27s modulus, as well as working time, setting time and injectability. The novel Zn-GPC formulations performed well, with prolonged mechanical strength (39 MPa, compression) greater than both vertebral bone (18.4 MPa) and the commercial control (14 MPa). However, working times (2 min) and rheological properties of Zn-GPCs, though improved, require further modifications prior to their use in minimally invasive surgical techniques. © 2009 Springer Science+Business Media, LLC
    • …
    corecore