3,010 research outputs found

    Intrinsic Luminescence from Self-Trapped Excitons in Bi4Ge3O12 and Bi12GeO20: Decay Kinetics and Multiplication of Electronic Excitations

    Get PDF
    The intrinsic luminescence appearing at 500 nm in Bi4Ge3O12 (e-BGO) and that at 450 nm in Bi12GeO20 (s-BGO) have been studied over a wide range of temperature T = 5–300 K by using a Nd:YAG laser and synchrotron radiation as excitation light sources. Luminescence decay curves in e-BGO depend dramatically on the laser power; they are composed of three decay components under high-density excitation, while they show a single exponential decay at low-density excitation. From temperature dependences of the decay time and emission intensity, it is clarified that the triplet state of a self-trapped exciton (STE) responsible for the e-BGO luminescence consists of a pair of closely spaced sublevels with separation energy of 5.7 meV. The decay curves of s-BGO luminescence are essentially nonexponential, irrespective of the excitation power. Time-resolved luminescence measurements of s-BGO suggest the existence of a singlet state lying higher than the triplet STE state. The excitation spectra for the intrinsic luminescence bands have been measured up to 35 eV (35 nm) at 5 K. From the obtained spectra, it is obvious that the multiplication of electronic excitations takes place efficiently in both BGOs. The production processes of multiple excitons are discussed by referring to a recent study on the electronic structures. ©2010 The Physical Society of JapanArticleJournal of Physical Society of Japan. 79:074717 (2010)journal articl

    Efficacy of combined peroxisome proliferator-activated receptor-α ligand and glucocorticoid therapy in a murine model of atopic dermatitis.

    Get PDF
    Although topical glucocorticoids (GCs) show potent anti-inflammatory activity in inflamed skin, they can also exert numerous harmful effects on epidermal structure and function. In contrast, topical applications of ligands of peroxisome proliferator-activated receptor-α (PPARα) not only reduce inflammation but also improve cutaneous barrier homeostasis. Therefore, we examined whether sequential topical GCs followed by topical Wy14643 (a ligand of PPARα) might be more effective than either alone for atopic dermatitis (AD) in a hapten (oxazolone (Ox))-induced murine model with multiple features of AD (Ox-AD). Despite expected anti-inflammatory benefits, topical GC alone induced (i) epidermal thinning; (ii) reduced expression of involucrin, loricrin, and filaggrin; and (iii) allowed outside-to-inside penetration of an epicutaneous tracer. Although Wy14643 alone yielded significant therapeutic benefits in mice with mild or moderate Ox-AD, it was less effective in severe Ox-AD. Yet, topical application of Wy14643 after GC was not only significantly effective comparable with GC alone, but it also prevented GC-induced structural and functional abnormalities in permeability barrier homeostasis. Moreover, rebound flares were largely absent after sequential treatment with GC and Wy14643. Together, these results show that GC and PPARα ligand therapy together is not only effective but also prevents development of GC-induced side effects, including rebound flares, in murine AD

    Comparative study of excitonic structures and luminescence properties of Bi4Ge3O12 and Bi12GeO20

    Get PDF
    Published in physica status solidi (b), Vol. 245, No. 12, pp2733-2736, 2008.Bi12GeO20 crystals have been performed, in addition to relativistic molecular orbital calculations. Both materials consist of the same elements but form different crystal structures. Based on the obtained results, the excitonic reflection structures and luminescence properties of Bi4Ge3O12 and Bi12GeO20 are discussed in comparison with each other.Bookphysica status solidi (b). 245(12):2733-2736 (2008)journal articl

    Optical anisotropy and electronic structures of CdMoO4 and CdWO4 crystals: Polarized reflection measurements, x-ray photoelectron spectroscopy, and electronic structure calculations

    Get PDF
    Copyright (c) 2008 American Physical SocietyArticlePHYSICAL REVIEW B. 77(15): 155118 (2008)journal articl

    Infrared/optical - X-ray simultaneous observations of X-ray flares in GRB 071112C and GRB 080506

    Get PDF
    We investigate the origin of short X-ray flares which are occasionally observed in early stages of afterglows of gamma-ray bursts (GRBs). We observed two events, GRB 071112C and GRB 080506, before the start of X-ray flares in the optical and near-infrared (NIR) bands with the 1.5-m Kanata telescope. In conjunction with published X-ray and optical data, we analyzed densely sampled light curves of the early afterglows and spectral energy distributions (SEDs) in the NIR-X-ray ranges. We found that the SEDs had a break between the optical and X-ray bands in the normal decay phases of both GRBs regardless of the model for the correction of the interstellar extinction in host galaxies of GRBs. In the X-ray flares, X-ray flux increased by 3 and 15 times in the case of GRB 071112C and 080506, respectively, and the X-ray spectra became harder than those in the normal decay phases. No significant variation in the optical-NIR range was detected together with the X-ray flares. These results suggest that the X-ray flares were associated with either late internal shocks or external shocks from two-component jets.Comment: 10 pages, 5 figures, accepted to Astronomy and Astrophysic

    TARGET: A Digitizing And Trigger ASIC For The Cherenkov Telescope Array

    Full text link
    The future ground-based gamma-ray observatory Cherenkov Telescope Array (CTA) will feature multiple types of imaging atmospheric Cherenkov telescopes, each with thousands of pixels. To be affordable, camera concepts for these telescopes have to feature low cost per channel and at the same time meet the requirements for CTA in order to achieve the desired scientific goals. We present the concept of the TeV Array Readout Electronics with GSa/s sampling and Event Trigger (TARGET) Application Specific Circuit (ASIC), envisaged to be used in the cameras of various CTA telescopes, e.g. the Gamma-ray Cherenkov Telescope (GCT), a proposed 2-Mirror Small-Sized Telescope, and the Schwarzschild-Couder Telescope (SCT), a proposed Medium-Sized Telescope. In the latest version of this readout concept the sampling and trigger parts are split into dedicated ASICs, TARGET C and T5TEA, both providing 16 parallel input channels. TARGET C features a tunable sampling rate (usually 1 GSa/s), a 16k sample deep buffer for each channel and on-demand digitization and transmission of waveforms with typical spans of ~100 ns. The trigger ASIC, T5TEA, provides 4 low voltage differential signal (LVDS) trigger outputs and can generate a pedestal voltage independently for each channel. Trigger signals are generated by T5TEA based on the analog sum of the input in four independent groups of four adjacent channels and compared to a threshold set by the user. Thus, T5TEA generates four LVDS trigger outputs, as well as 16 pedestal voltages fed to TARGET C independently for each channel. We show preliminary results of the characterization and testing of TARGET C and T5TEA.Comment: 6 pages, 8 figures, Proceedings of the 6th International Symposium on High-Energy Gamma-Ray Astronomy (Gamma2016

    Evidence-Based Decision Making in Local Health Departments

    Get PDF
    Evidence-based decision making (EBDM) represents an important strategy to increase efficacy and efficiency of public health programs and practice. There is insufficient information on the application of EBDM among local health departments (LHDs). This qualitative study examined use of EBDM in New York State (NYS) LHDs and factors facilitating and impeding its adoption through interviews and focus groups with 47 LHD commissioners, health directors, and other upper-level staff. Findings suggest variability in application of EBDM in NYS LHDs. A number of internal factors (e.g., staff capacity, organizational culture) and external factors (e.g., policy environment, appropriate and replicable evidence-based models) contribute to its uneven use, even within a single LHD

    The Optical System for the Large Size Telescope of the Cherenkov Telescope Array

    Full text link
    The Large Size Telescope (LST) of the Cherenkov Telescope Array (CTA) is designed to achieve a threshold energy of 20 GeV. The LST optics is composed of one parabolic primary mirror 23 m in diameter and 28 m focal length. The reflector dish is segmented in 198 hexagonal, 1.51 m flat to flat mirrors. The total effective reflective area, taking into account the shadow of the mechanical structure, is about 368 m2^2. The mirrors have a sandwich structure consisting of a glass sheet of 2.7 mm thickness, aluminum honeycomb of 60 mm thickness, and another glass sheet on the rear, and have a total weight about 47 kg. The mirror surface is produced using a sputtering deposition technique to apply a 5-layer coating, and the mirrors reach a reflectivity of ∼\sim94% at peak. The mirror facets are actively aligned during operations by an active mirror control system, using actuators, CMOS cameras and a reference laser. Each mirror facet carries a CMOS camera, which measures the position of the light spot of the optical axis reference laser on the target of the telescope camera. The two actuators and the universal joint of each mirror facet are respectively fixed to three neighboring joints of the dish space frame, via specially designed interface plate.Comment: In Proceedings of the 34th International Cosmic Ray Conference (ICRC2015), The Hague, The Netherlands. All CTA contributions at arXiv:1508.0589

    KRAS or BRAF mutation status is a useful predictor of sensitivity to MEK inhibition in ovarian cancer

    Get PDF
    This study examined the status of KRAS and BRAF mutations, in relation to extracellular signal-regulated protein kinase (ERK) activation in 58 ovarian carcinomas to clarify the clinicopathological and prognostic significance of KRAS/BRAF mutations. Somatic mutations of either KRAS or BRAF were identified in 12 (20.6%) out of 58 ovarian carcinomas. The frequency of KRAS/BRAF mutations in conventional serous high-grade carcinomas (4.0% : 1/25) was significantly lower than that in the other histological type (32.3% : 10/31). Phosphorylated ERK1/2 (p-ERK1/2) expression was identified in 18 (38.2%) out of 45 ovarian carcinomas. KRAS/BRAF mutation was significantly correlated with International Federation of Gynecology and Obstetrics (FIGO) stage I, II (P<0.001), and p-ERK1/2 (P<0.001). No significant correlations between KRAS/BRAF mutations or p-ERK1/2 expression and overall survival were found in patients with ovarian carcinoma treated with platinum and taxane chemotherapy (P=0.2460, P=0.9339, respectively). Next, to clarify the roles of ERK1/2 activation in ovarian cancers harbouring KRAS or BRAF mutations, we inactivated ERK1/2 in ovarian cancer cells using CI-1040. Cl-1040 is a compound that selectively inhibits MAP kinase kinase (MEK), an upstream regulator of ERK1/2, and thus prevents ERK1/2 activation. Profound growth inhibition and apoptosis were observed in CI-1040-treated cancer cells with mutations in either KRAS or BRAF in comparison with the ovarian cancer cells containing wild-type sequences. This was evident in both in vitro and in vivo studies. The findings in this study indicate that an activated ERK1/2 pathway is critical to tumour growth and survival of ovarian cancers with KRAS or BRAF mutations. Furthermore, they suggest that the CI-1040-induced phenotypes depend on the mutational status of KRAS and BRAF in ovarian cancers. Therefore, ovarian cancer patients with KRAS or BRAF mutations may benefit from CI-1040 treatment
    • …
    corecore