142 research outputs found

    Endovascular repair versus open surgery in patients with ruptured abdominal aortic aneurysms: Clinical outcomes with 1-year follow-up

    Get PDF
    ObjectiveTo compare the clinical outcomes of treatment after endovascular repair and open surgery in patients with ruptured infrarenal abdominal aortic aneurysms (AAAs), including 1-year follow-up.MethodsAll consecutive conscious patients with ruptured infrarenal AAAs who presented to our tertiary care teaching hospital between January 1, 2001, and December 31, 2005, were included in this study (n = 55). Twenty-six patients underwent endovascular repair, and 29 patients underwent open surgery. Patients who were hemodynamically too unstable to undergo a computed tomography angiography scan were excluded. Outcomes evaluated were intraoperative mortality, 30-day mortality, systemic complications, complications necessitating surgical intervention, and mortality and complications during 1-year follow-up. The statistical tests we used were the Student t test, χ2 test, Fisher exact test, and Mann-Whitney U test (two sided; α = .05).ResultsThirty-day mortality was 8 (31%) of 26 patients who underwent endovascular repair and 9 (31%) of 29 patients who underwent open surgery (P = .98). Systemic complications and complications necessitating surgical intervention during the initial hospital stay were similar in both treatment groups (8/26 [31%] and 5/26 [19%] for endovascular repair, respectively, and 9/29 [31%] and 8/29 [28%] for open surgery, respectively; P > .40). During 1-year follow-up, two patients initially treated with endovascular repair died as a result of non–aneurysm-related causes; no death occurred in the open surgery group. Complications during 1-year follow-up were 1 (5%) of 20 for endovascular repair and 4 (16%) of 25 for open surgery (P = .36).ConclusionsOn the basis of our study with a highly selected population, the mortality and complication rates after endovascular repair may be similar compared with those after open surgery in patients treated for ruptured infrarenal AAAs

    Accurate assessment of abdominal aortic aneurysm with intravascular ultrasound scanning: Validation with computed tomographic angiography

    Get PDF
    AbstractPurpose: The purpose of this study was to assess the accuracy of intravascular ultrasound (IVUS) parameters of abdominal aortic aneurysm, used for endovascular grafting, in comparison with computed tomographic angiography (CTA). Methods: This study was designed as a descriptive study. Between March 1997 and March 1998, 16 patients with abdominal aortic aneurysms were studied with angiography, IVUS (12.5 MHz), and CTA. The length of the aneurysm and the length and lumen diameter of the proximal and distal neck obtained with IVUS were compared with the data obtained with CTA. The measurements with IVUS were repeated by a second observer to assess the reproducibility. Tomographic IVUS images were reconstructed into a longitudinal format. Results: IVUS results identified 31 of 32 renal arteries and four of five accessory renal arteries. A comparison of the length measurements of the aneurysm and the proximal and distal neck obtained with IVUS and CTA revealed a correlation of 0.99 (P < .001), with a coefficient of variation of 9%. IVUS results tended to underestimate the length as compared with the CTA results (0.48 ± 0.52 cm; P < .001). A comparison of the lumen diameter measurements of the proximal and distal neck derived from IVUS and CTA showed a correlation of 0.93 (P < .001), with a coefficient of variation of 9%. IVUS results tended to underestimate aneurysm neck diameter as compared with CTA results (0.68 ± 1.76 mm; P = .006). Interobserver agreement of IVUS length and diameter measurements showed a good correlation (r = 1.0; P < .001), with coefficients of variation of 3% and 2%, respectively, and no significant differences (0.0 ± 0.16 cm and 0.06 ± 0.36 mm, respectively). The longitudinal IVUS images displayed the important vascular structures and improved the spatial insight in aneurysmal anatomy. Conclusion: Intravascular ultrasound scanning results provided accurate and reproducible measurements of abdominal aortic aneurysm. The longitudinal reconstruction of IVUS images provided additional knowledge on the anatomy of the aneurysm and its proximal and distal neck. (J Vasc Surg 1999;29:631-8.

    Performance of the BioIntegral Bovine Pericardial Graft in Vascular Infections:VASCular No-REact Graft Against INfection Study

    Get PDF
    Background: Vascular graft and endograft infections (VGEI) and native vessel infections (NVI) remain considerable challenges in vascular surgery, leading to high mortality and morbidity rates. Although in situ reconstruction is the preferred treatment, the material of choice is still a source of debate. Autologous veins are considered the first choice; however, xenografts may be an acceptable alternative. The performance of a biomodified bovine pericardial graft is assessed when implemented in an infected vascular area. Methods: This is a prospective multicenter cohort study. Patients who underwent reconstruction for VGEI or NVI with a biomodified bovine pericardial bifurcated or straight tube graft were included from December 2017 until June 2021. The primary outcome measure was reinfection at mid-term follow-up. Secondary outcome measures included mortality, patency, and amputation rate. Results: Thirty-four patients with vascular infections were included, of which 23 (68%) had an infected Dacron prosthesis after primary open repair and 8 (24%) had an infected endovascular graft. The remaining 3 (9%) had infected native vessels. At secondary repair, 3 (7%) patients had an in situ aortic tube reconstruction, 29 (66%) had an aortic bifurcated reconstruction, and 2 (5%) had an iliac-femoral reconstruction. At 1-year follow-up after the BioIntegral bovine pericardial graft reconstruction, the reinfection rate was 9%. The 1-year infection-related and procedure-related mortality rate was 16%. The occlusion rate was 6% and in total 3 patients underwent a lower limb amputation during the 1-year follow-up period. Conclusions: In situ reconstruction as treatment of (endo)graft and native vessel infections remains a challenge and reinfection looms as a potential consequence. In cases where time is of essence or when autologous venous repair is not feasible, a swift available solution is needed. The BioIntegral biomodified bovine pericardial graft may be an option as it shows reasonable results in terms of reinfection, in aortic tube and bifurcated grafts.</p

    Lessons to be learned from the coherent photoproduction of pseudoscalar mesons

    Get PDF
    We study the coherent photoproduction of pseudoscalar mesons---particularly of neutral pions---placing special emphasis on the various sources that put into question earlier nonrelativistic-impulse-approximation calculations. These include: final-state interactions, relativistic effects, off-shell ambiguities, and violations to the impulse approximation. We establish that, while distortions play an essential role in the modification of the coherent cross section, the uncertainty in our results due to the various choices of optical-potential models is relatively small (of at most 30%). By far the largest uncertainty emerges from the ambiguity in extending the many on-shell-equivalent representations of the elementary amplitude off the mass shell. Indeed, relativistic impulse-approximation calculations that include the same pionic distortions, the same nuclear-structure model, and two sets of elementary amplitudes that are identical on-shell, lead to variations in the magnitude of the coherent cross section by up to factors of five. Finally, we address qualitatively the assumption of locality implicit in most impulse-approximation treatments, and suggest that the coherent reaction probes---in addition to the nuclear density---the polarization structure of the nucleus.Comment: Manuscript is 27 pages long and includes 11 eps figure

    The 3^3He(e, eâ€Č'd)p Reaction in qω\omega-constant Kinematics

    Full text link
    The cross section for the 3^3He(e, eâ€Č'd)p reaction has been measured as a function of the missing momentum pmp_m in qω\omega -constant kinematics at beam energies of 370 and 576 MeV for values of the three-momentum transfer qq of 412, 504 and 604 \mevc. The L(+TT), T and LT structure functions have been separated for qq = 412 and 504 \mevc. The data are compared to three-body Faddeev calculations, including meson-exchange currents (MEC), and to calculations based on a covariant diagrammatic expansion. The influence of final-state interactions and meson-exchange currents is discussed. The pmp_m-dependence of the data is reasonably well described by all calculations. However, the most advanced Faddeev calculations, which employ the AV18 nucleon-nucleon interaction and include MEC, overestimate the measured cross sections, especially the longitudinal part, and at the larger values of qq. The diagrammatic approach gives a fair description of the cross section, but under(over)estimates the longitudinal (transverse) structure function.Comment: 17 pages, 7 figure

    Endovascular repair versus open surgery in patients with ruptured abdominal aortic aneurysms: Clinical outcomes with 1-year follow-up

    Get PDF
    ObjectiveTo compare the clinical outcomes of treatment after endovascular repair and open surgery in patients with ruptured infrarenal abdominal aortic aneurysms (AAAs), including 1-year follow-up.MethodsAll consecutive conscious patients with ruptured infrarenal AAAs who presented to our tertiary care teaching hospital between January 1, 2001, and December 31, 2005, were included in this study (n = 55). Twenty-six patients underwent endovascular repair, and 29 patients underwent open surgery. Patients who were hemodynamically too unstable to undergo a computed tomography angiography scan were excluded. Outcomes evaluated were intraoperative mortality, 30-day mortality, systemic complications, complications necessitating surgical intervention, and mortality and complications during 1-year follow-up. The statistical tests we used were the Student t test, χ2 test, Fisher exact test, and Mann-Whitney U test (two sided; α = .05).ResultsThirty-day mortality was 8 (31%) of 26 patients who underwent endovascular repair and 9 (31%) of 29 patients who underwent open surgery (P = .98). Systemic complications and complications necessitating surgical intervention during the initial hospital stay were similar in both treatment groups (8/26 [31%] and 5/26 [19%] for endovascular repair, respectively, and 9/29 [31%] and 8/29 [28%] for open surgery, respectively; P > .40). During 1-year follow-up, two patients initially treated with endovascular repair died as a result of non–aneurysm-related causes; no death occurred in the open surgery group. Complications during 1-year follow-up were 1 (5%) of 20 for endovascular repair and 4 (16%) of 25 for open surgery (P = .36).ConclusionsOn the basis of our study with a highly selected population, the mortality and complication rates after endovascular repair may be similar compared with those after open surgery in patients treated for ruptured infrarenal AAAs

    Five Year Outcomes of the Endurant Stent Graft for Endovascular Abdominal Aortic Aneurysm Repair in the ENGAGE Registry

    Get PDF
    Objective/background: Endovascular abdominal aortic aneurysm repair (EVAR) is commonly used to treat abdominal aortic aneurysm (AAA). However, the incidence of long-term complications and the need for re-interventions after EVAR remains a concern. Newer generation stent grafts have encouraging short and mid-term outcomes, but thorough analysis of their long-term performance is necessary. Methods: The ENGAGE registry includes a total of 1263 patients with AAA enrolled from March 2009 to April 2011 at 79 centres across 30 countries. The aim of this study is to present standard EVAR outcomes in the registry after five years. Results: A significant proportion of the ENGAGE patients presented with challenging features, such as 15.2% with an AAA diameter >7 cm, 12.0% with proximal neck lengths 60°. Of the 1263 enrolled subjects, 17.8% were implanted outside of the instructions for use for the device. At the five year follow up, the Kaplan–Meier overall survival rate was 67.4% and the freedom from aneurysm related mortality was 97.8%. Freedom from aneurysm rupture, secondary procedures, and conversion to open repair at five years were 98.6%, 84.3%, and 97.9% respectively. The five year freedom from type IA endoleaks was 95.2% and for type III endoleaks 97.4%. Aneurysm sac diameter at five years was observed to have either decreased ≄5 mm in diameter or remained stable in 89.4% of the patients. Conclusion: Five year follow up of patients in the ENGAGE registry demonstrates sustained safety, effectiveness, and durability in an international cohort that is reflective of real world experience. Additional follow up is expected through to 10 years
    • 

    corecore