    Coaxial carbon plasma gun deposition of amorphous carbon films

    Get PDF
    A unique plasma gun employing coaxial carbon electrodes was used in an attempt to deposit thin films of amorphous diamond-like carbon. A number of different structural, compositional, and electrical characterization techniques were used to characterize these films. These included scanning electron microscopy, scanning transmission electron microscopy, X ray diffraction and absorption, spectrographic analysis, energy dispersive spectroscopy, and selected area electron diffraction. Optical absorption and electrical resistivity measurements were also performed. The films were determined to be primarily amorphous, with poor adhesion to fused silica substrates. Many inclusions of particulates were found to be present as well. Analysis of these particulates revealed the presence of trace impurities, such as Fe and Cu, which were also found in the graphite electrode material. The electrodes were the source of these impurities. No evidence of diamond-like crystallite structure was found in any of the film samples. Details of the apparatus, experimental procedure, and film characteristics are presented

    Sputtered coatings for protection of spacecraft polymers

    Get PDF
    Kapton polyimide oxidizes at significant rates (4.3x10(-24) gram/incident oxygen atom) when exposed in low Earth orbit to the ram atomic oxygen flux. Ion beam sputter deposited thin films of Al2O3 and SiO2 as well as a codeposited mixture of predominantly SiO2 with a small amount of polytetrafluoroethylene were evaluated and found to be effective in protecting Kapton from oxidation in both laboratory plasma ashing tests as well as in space on board shuttle flight STS-8. A protective film of or = 96 percent SiO2 and or = 4 percent polytetrafluoroethylene was found to be very flexible compared to the pure metal oxide coatings and resulted in mass loss rates that were 0.2 percent of that of the unprotected Kapton. The optical properties of Kapton for wavelengths investigated between 0.33 and 2.2 microns were not significantly altered by the presence of the coatings or changed by exposure of the coated Kapton to the low Earth orbital ram environment

    Disposal of Household Wastewater in Soils of High Stone Content (1981-1983)

    Get PDF
    Four experimental filter fields were constructed with built-in monitoring equipment in Nixa soils. These soils contain many chert fragments and a fragipan about 60 cm below the soil surface. The fragipan restricts downward movement of water and is the designlimitingfeature. The four filter fields were: 1. A standard filter field, 76 cm deep. The bottom of the trench was in the fragipan. 2. A modified standard filter field, 30 cm deep. The bottom of the trench was above the fragipan. 3. A modified pressure filter field, 40 cm deep. The bottom of the trench was above the fragipan. In addition, a pressure-distribution system was used to insure uniform distribution of effluent in the trench. Inadvertently, this field was installed in a different soil, and the results cannot be compared directly with the other three. 4. Another modified pressure filter field with the bottom of the trench only 6 cm below the soil surface. Observation of these systems confirms that placing filter fields higher in the soil above the hydraulically limiting horizon results in improved hydraulic performance. The presence of the fragipan amplified the adverse effects attributable to climatic stress. The seepage beds which are higher in the soil profile are able to handle the effluent load and climate load with less danger of surfacing

    Picosecond electrical spectroscopy using monolithic GaAs circuits

    Get PDF
    This article describes an experimental apparatus for free-space mm-wave transmission measurements (spectroscopy). GaAs nonlinear transmission lines and sampling circuits are used as picosecond pulse generators and detectors, with planar monolithic bowtie antennas with associated substrate lenses used as the radiating and receiving elements. The received pulse is 270 mV amplitude and 2.4 ps rise time. Through Fourier transformation of the received pulse, 30–250 GHz measurements are demonstrated with <=0.3 dB (rms) accuracy

    GRB011211: An alternative interpretation of the optical and X-ray spectra in terms of blueshifts

    Full text link
    The redshifts of the gamma ray burst (GRB) GRB 011211 has been determined as 2.14 from several absorption lines seen in the spectrum of its optical afterglow. The spectrum of its X-ray afterglow exhibited several emission lines,and their identification led to a mean redshift 1.862. A supernova model has been proposed based on the redshift of the GRB as 2.141. It is shown here that the redshift interpretation cannot explain the observed spectra, as some serious inconsistencies exist in the process of redshift determinations in spectra of both optical and X-ray afterglows. In view of that, an alternative interpretation of the spectra is presented in terms of blueshifts. Ejection mechanism is proposed as a possible scenario to explain the blueshifted spectrum.Comment: 26 pages, one table; in Canadian Journal of Physics, June 200

    Highly efficient frequency triplers in the millimeter wave region incorporating a back-to-back configuration of two varactor diodes

    Get PDF
    This paper reports on the recent development of monolithic frequency tripler array employing a back-to-back configuration of varactor diodes. Even harmonic idler circuits are unnecessary in this design. Furthermore, no external dc bias is required. The arrangement results in highly efficient, easily-fabricated and inexpensive frequency triplers

    Ion beam sputter-deposited thin film coatings for protection of spacecraft polymers in low Earth orbit

    Get PDF
    Ion beam sputter-deposited thin films of Al2O3, SiO2, and a codeposited mixture of predominantly SiO2 with small amounts of a fluoropolymer were evaluated both in laboratory plasma ashing tests and in space on board shuttle flight STS-8 for effectiveness in preventing oxidation of polyimide Kapton. Measurements of mass loss and optical performance of coated and uncoated polyimide samples exposed to the low Earth orbital environment are presented. Optical techniques were used to measure loss rates of protective films exposed to atomic oxygen. Results of the analysis of the space flight exposed samples indicate that thin film metal oxide coatings are very effective in protecting the polyimide. Metal oxide coatings with a small amount of fluoropolymer codeposited have the additional benefit of great flexibility

    Cosmological versus Intrinsic: The Correlation between Intensity and the Peak of the nu F_nu Spectrum of Gamma Ray Bursts

    Get PDF
    We present results of correlation studies, examining the association between the peak of the nu F_nu spectrum of gamma ray bursts, E_p, with the burst's energy fluence and photon peak flux. We discuss methods to account for data truncation in E_p and fluence or flux when performing the correlation analyses. However, because bursts near the detector threshold are not usually able to provide reliable spectral parameters, we focus on results for the brightest bursts in which we can better understand the selection effects relevant to E_p and burst strength. We find that there is a strong correlation between total fluence and E_p. We discuss these results in terms of both cosmological and intrinsic effects. In particular, we show that for realistic distributions of the burst parameters, cosmological expansion alone cannot account for the correlation between E_p and total fluence; the observed correlation is likely a result of an intrinsic relation between the burst rest-frame peak energy and the total radiated energy. We investigate this latter scenario in the context of synchrotron radiation from external and internal shock models of GRBs. We find that the internal shock model is consistent with our interpretation of the correlation, while the external shock model cannot easily explain this intrinsic relation between peak energy and burst radiated energy.Comment: 23 pages, including 8 postscript figures. Submitted to Ap

    Re: Sleep and the Family Doctor: Time to Lead

    Get PDF
    • …
    corecore