1,391 research outputs found

    Atomic carbon chains as spin-transmitters: an \textit{Ab initio} transport study

    Full text link
    An atomic carbon chain joining two graphene flakes was recently realized in a ground-breaking experiment by Jin {\it et al.}, Phys. Rev. Lett. {\bf 102}, 205501 (2009). We present {\it ab initio} results for the electron transport properties of such chains and demonstrate complete spin-polarization of the transmission in large energy ranges. The effect is due to the spin-polarized zig-zag edge terminating each graphene flake causing a spin-splitting of the graphene πz\pi_z bands, and the chain states. Transmission occurs when the graphene π\pi-states resonate with similar states in the strongly hybridized edges and chain. This effect should in general hold for any π\pi-conjugated molecules bridging the zig-zag edges of graphene electrodes. The polarization of the transmission can be controlled by chemically or mechanically modifying the molecule, or by applying an electrical gate

    Searching for the Donor Stars of ULX Pulsars

    Get PDF
    We report on our search for the optical counterparts of two ultraluminous X-ray pulsars with known orbital periods, M82 X-2 and NGC 5907 X-1, in new and archival HST observations, in an effort to characterize the donor stars in these systems. We detect five near-infrared sources consistent with the position of M82 X-2 that are too bright to be single stars. We also detect seven sources in the WFC3/UVIS F336W image whose photometry matches that of 10-15 M_\odot stars turning off the main sequence. Such stars have densities consistent with the properties of the donor star of M82 X-2 as inferred from X-ray timing analysis, although it is also possible that the donor is a lower mass star below our detection limit or that there is a significant contribution from the accretion disc to the optical emission. We detect three candidate counterparts to NGC 5907 X-1 in the near-infrared. All of these are too bright to be the donor star of the ULX, which based on its orbital period is a red giant. The high background at the location of NGC 5907 X-1 precludes us from detecting this expected donor star. The recently discovered NGC 5907 ULX-2 also falls within the field of view of the near-infrared imaging; we detect four sources in the error circle, with photometry that matches AGB stars. The star suggested to be the counterpart of NGC 5907 ULX-2 by Pintore et al. (2018) falls outside our 2-σ\sigma error circle.Comment: 10 pages, 3 figures, accepted for publication in Ap

    Distorted cyclotron line profile in Cep X-4 as observed by NuSTAR

    Get PDF
    We present spectral analysis of NuSTAR and Swift observations of Cep X-4 during its outburst in 2014. We observed the source once during the peak of the outburst and once during the decay, finding good agreement in the spectral shape between the observations. We describe the continuum using a powerlaw with a Fermi-Dirac cutoff at high energies. Cep X-4 has a very strong cyclotron resonant scattering feature (CRSF) around 30 keV. A simple absorption-like line with a Gaussian optical depth or a pseudo-Lorentzian profile both fail to describe the shape of the CRSF accurately, leaving significant deviations at the red side of the line. We characterize this asymmetry with a second absorption feature around 19 keV. The line energy of the CRSF, which is not influenced by the addition of this feature, shows a small but significant positive luminosity dependence. With luminosities between (1-6)e36 erg/s, Cep X-4 is below the theoretical limit where such a correlation is expected. This behavior is similar to Vela X-1 and we discuss parallels between the two systems.Comment: 6 pages, 4 figure, accepted for publication in ApJ letter

    Evidence for a Variable Ultrafast Outflow in the Newly Discovered Ultraluminous Pulsar NGC 300 ULX-1

    Get PDF
    Ultraluminous pulsars are a definite proof that persistent super-Eddington accretion occurs in nature. They support the scenario according to which most Ultraluminous X-ray Sources (ULXs) are super-Eddington accretors of stellar mass rather than sub-Eddington intermediate mass black holes. An important prediction of theories of supercritical accretion is the existence of powerful outflows of moderately ionized gas at mildly relativistic speeds. In practice, the spectral resolution of X-ray gratings such as RGS onboard XMM-Newton is required to resolve their observational signatures in ULXs. Using RGS, outflows have been discovered in the spectra of 3 ULXs (none of which are currently known to be pulsars). Most recently, the fourth ultraluminous pulsar was discovered in NGC 300. Here we report detection of an ultrafast outflow (UFO) in the X-ray spectrum of the object, with a significance of more than 3{\sigma}, during one of the two simultaneous observations of the source by XMM-Newton and NuSTAR in December 2016. The outflow has a projected velocity of 65000 km/s (0.22c) and a high ionisation factor with a log value of 3.9. This is the first direct evidence for a UFO in a neutron star ULX and also the first time that this its evidence in a ULX spectrum is seen in both soft and hard X-ray data simultaneously. We find no evidence of the UFO during the other observation of the object, which could be explained by either clumpy nature of the absorber or a slight change in our viewing angle of the accretion flow.Comment: 10 pages, 4 figures. Accepted to MNRA

    An XMM-Newton and NuSTAR study of IGR J18214-1318: a non-pulsating high-mass X-ray binary with a neutron star

    Get PDF
    IGR J18214-1318, a Galactic source discovered by the International Gamma-Ray Astrophysics Laboratory, is a high-mass X-ray binary (HMXB) with a supergiant O-type stellar donor. We report on the XMM-Newton and NuSTAR observations that were undertaken to determine the nature of the compact object in this system. This source exhibits high levels of aperiodic variability, but no periodic pulsations are detected with a 90% confidence upper limit of 2% fractional rms between 0.00003-88 Hz, a frequency range that includes the typical pulse periods of neutron stars (NSs) in HMXBs (0.1-103^3 s). Although the lack of pulsations prevents us from definitively identifying the compact object in IGR J18214-1318, the presence of an exponential cutoff with e-folding energy 30\lesssim30 keV in its 0.3-79 keV spectrum strongly suggests that the compact object is an NS. The X-ray spectrum also shows a Fe Kα\alpha emission line and a soft excess, which can be accounted for by either a partial-covering absorber with NH1023N_{\mathrm{H}}\approx10^{23} cm2^{-2} which could be due to the inhomogeneous supergiant wind, or a blackbody component with kT=1.740.05+0.04kT=1.74^{+0.04}_{-0.05} keV and RBB0.3R_{BB}\approx0.3 km, which may originate from NS hot spots. Although neither explanation for the soft excess can be excluded, the former is more consistent with the properties observed in other supergiant HMXBs. We compare IGR J18214-1318 to other HMXBs that lack pulsations or have long pulsation periods beyond the range covered by our observations.Comment: 15 pages, 12 figures, 4 table

    Zystoskopie bei einem Rind mit Urachus persistens-Ruptur

    Full text link
    Die Arbeit beschreibt die klinischen, sonographischen und zystoskopischen Befunde sowie die Therapie bei einem 2-jährigen, 7 Monate trächtigen Braunviehrind mit Ruptur des Urachus persistens. Das Leitsymptom war ein birnförmiges Abdomen bei stark gestörtem Allgemeinbefinden. Die Blutuntersuchung ergab eine hochgradige Azotämie. Bei der Ultraschalluntersuchung wurde ein Aszites festgestellt, welcher aufgrund der massiv erhöhten Kreatininkonzentration im Punktat als Uroperitoneum klassiert wurde. Bei der Zystoskopie konnte das Endoskop über die Harnblase in einen persistierenden Urachus eingeführt werden. Aufgrund sämtlicher Befunde wurde die Diagnose Uroperitoneum infolge Ruptur eines Urachus persistens gestellt. Als Therapie wurde eine Laparotomie in der linken Flanke mit doppelter Ligation des Urachus durchgeführt. Innerhalb von wenigen Tagen normalisierte sich der Zustand des Rindes. Es hat inzwischen normal gekalbt und erfreut sich bester Gesundheit This case report describes the clinical, ultrasonographic and cystoscopic findings and treatment in a two-year-old Swiss Braunvieh heifer with rupture of a patent urachus. The lead signs in the seven-month-pregnant heifer were markedly abnormal general condition and demeanour and a pear-shaped abdomen. The heifer had severe azotaemia, and abdominal ultrasonography revealed ascites, which was diagnosed as uroperitoneum based on an elevated creatinine level in the fluid. A patent urachus was identified during cystoscopy; the endoscope could be advanced beyond the apex of the urinary bladder into the urachus. Based on all the findings, a diagnosis of uroperitoneum attributable to rupture of a patent urachus was made. The urachus was ligated twice via a left-flank laparotomy. The general condition normalised within a few days of surgery, and the patient calved normally and was in good health at follow-up evaluation

    Innovative methods in European road freight transport statistics: A pilot study

    Get PDF
    By using innovative methods, such as the automated transfer of corporate electronic data to National Statistical Institutions, official transport data can be significantly improved in terms of reliability, costs and the burden on respondents. In this paper, we show that the automated compilation of statistical reports is possible and feasible. Based on previous findings, a new method and tool were developed in cooperation with two business partners from the logistics sector in Austria. The results show that the prototype could successfully be implemented at the partner companies. Improved data quality can lead to more reliable analyses in various fields. Compared to actual volumes of investments into transport, the costs of transport statistics are limited. By using the new and innovative data collection techniques, these costs can even be reduced in the long run; at the same time, the risk of bad investments and wrong decisions caused by analyses relying on poor data quality can be reduced. This results in a substantial value for business, research, the economy and the society

    Localized Edge Vibrations and Edge Reconstruction by Joule Heating in Graphene Nanostructures

    Get PDF
    Under the terms of the Creative Commons Attribution License 3.0 (CC-BY).Control of the edge topology of graphene nanostructures is critical to graphene-based electronics. A means of producing atomically smooth zigzag edges using electronic current has recently been demonstrated in experiments [Jia et al., Science 323, 1701 (2009)]. We develop a microscopic theory for current-induced edge reconstruction using density functional theory. Our calculations provide evidence for localized vibrations at edge interfaces involving unpassivated armchair edges. We demonstrate that these vibrations couple to the current, estimate their excitation by Joule heating, and argue that they are the likely cause of the reconstructions observed in the experiments.A. P. J. is grateful to the FiDiPro program of the Finnish Academy. Computational resources were provided by the Danish Center for Scientific Computing (DCSC).Peer reviewe
    corecore