453 research outputs found
Proposed magneto-electrostatic ring trap for neutral atoms
We propose a novel trap for confining cold neutral atoms in a microscopic
ring using a magneto-electrostatic potential. The trapping potential is derived
from a combination of a repulsive magnetic field from a hard drive atom mirror
and the attractive potential produced by a charged disk patterned on the hard
drive surface. We calculate a trap frequency of [29.7, 42.6, 62.8] kHz and a
depth of [16.1, 21.8, 21.8] MHz for [133Cs, 87Rb, 40K], and discuss a simple
loading scheme and a method for fabrication. This device provides a
one-dimensional potential in a ring geometry that may be of interest to the
study of trapped quantum degenerate one-dimensional gases.Comment: 4 pages, 2 figures; revised, including new calculations and further
discussio
Fabrication of Resorcinol-Formaldehyde Xerogel based High Aspect Ratio 3-D Hierarchical C-MEMS Structures
We demonstrate a novel method to fabricate arrays of resorcinol-
formaldehyde xerogel (RFX) based high aspect ratio (HAR) three-
dimensional (3-D) hierarchical C-MEMS structures. Starting from
a master pattern of HAR 3-D posts fabricated in SU-8 negative
photoresist by photolithography, a negative PDMS stamp with
arrays of holes was prepared by micromolding. The PDMS stamp
was then used to fabricate HAR 3-D RFX posts by replica molding.
The 3-D RFX posts thus fabricated were electrosprayed with SU-8
or an RF sol in the form of submicron or nano sized droplets and
followed by pyrolysis to yield HAR 3-D hierarchical carbon posts.
To characterize their use in C-MEMS based batteries,
galvanostatic (charge and discharge) experiments on RFX derived
carbon showed that it can be reversibly intercalated with Li ions
and possesses superior intercalation properties as compared to SU-
8 derived carbon which is a widely used material in C-MEMS
A comparative investigation of thickness measurements of ultra-thin water films by scanning probe techniques
The reliable operation of micro and nanomechanical devices necessitates a
thorough knowledge of the water film thickness present on the surfaces of these
devices with an accuracy in the nm range. In this work, the thickness of an
ultra-thin water layer was measured by distance tunnelling spectroscopy and
distance dynamic force spectroscopy during desorption in an ultra-high vacuum
system, from about 2.5 nm up to complete desorption at 1E-8 mbar. The
tunnelling current as well as the amplitude of vibration and the normal force
were detected as a function of the probe-sample distance. In these experiments,
a direct conversion of the results of both methods is possible. From the
standpoint of surface science, taking the state-of-the-art concerning
adsorbates on surfaces into consideration, dynamic force spectroscopy provides
the most accurate values. The previously reported tunnelling spectroscopy,
requiring the application of significantly high voltages, generally leads to
values that are 25 times higher than values determined by dynamic force
spectroscopy
Surface scattering velocities in III-nitride quantum well laser structures via the emission of hybrid phonons
We have theoretically and numerically studied nitride-based quantum well (QW)
laser structures. More specifically, we have used a QW made with III-nitride
where the width of the barrier region is large relative to the electron mean
free path, and we have calculated the electron surface capture velocities by
considering an electron flux which is captured into the well region. The
process is assisted by the emission of the longitudinal optical phonons as
predicted by the hybrid (HB) model. The results of surface capture velocities
via the emission of HB phonons are compared to the emission of the dielectric
continuum phonons (Zakhleniuk et al 1999 Phys. Status Solidi a 176 79). Our
investigation shows that the two different phonon models predict almost the
same results for the non-retarded limit. Furthermore, the surface capture
velocities strongly depend on the size of the structure and the heterostructure
materials. Lastly, a comparison to the recent experimental values shows that
our model could accurately describe the experimentally measured parameters of
the quantum capture processes
Decoupled cantilever arms for highly versatile and sensitive temperature and heat flux measurements
Microfabricated cantilever beams have been used in microelectromechanical systems for a variety of sensor and actuator applications. Bimorph cantilevers accurately measure temperature change and heat flux with resolutions several orders of magnitude higher than those of conventional sensors such as thermocouples, semiconductor diodes, as well as resistance and infrared thermometers. The use of traditional cantilevers, however, entails a series of important measurement limitations, because their interactions with the sample and surroundings often create parasitic deflection forces and the typical metal layer degrades the thermal sensitivity of the cantilever. The paper introduces a design to address these issues by decoupling the sample and detector section of the cantilever, along with a thermomechanical model, the fabrication, system integration, and characterization. The custom-designed bi-arm cantilever is over one order of magnitude more sensitive than current commercial cantilevers due to the significantly reduced thermal conductance of the cantilever sample arm. The rigid and immobile sample section offers measurement versatility ranging from photothermal absorption, near-field thermal radiation down to contact, conduction, and material thermal characterization measurements in nearly identical configurations.United States. Dept. of Energy. Division of Materials Sciences and Engineering (DE-FG02-02ER45977)United States. Air Force Office of Scientific Research. Multidisciplinary University Research Initiative (UIUC FA9550-08-1-0407
Vacuum/Compression Valving (VCV) Using Parrafin-Wax on a Centrifugal Microfluidic CD Platform
This paper introduces novel vacuum/compression valves (VCVs) utilizing paraffin wax. A VCV is implemented by sealing the venting channel/hole with wax plugs (for normally-closed valve), or to be sealed by wax (for normally-open valve), and is activated by localized heating on the CD surface. We demonstrate that the VCV provides the advantages of avoiding unnecessary heating of the sample/reagents in the diagnostic process, allowing for vacuum sealing of the CD, and clear separation of the paraffin wax from the sample/reagents in the microfluidic process. As a proof of concept, the microfluidic processes of liquid flow switching and liquid metering is demonstrated with the VCV. Results show that the VCV lowers the required spinning frequency to perform the microfluidic processes with high accuracy and ease of control.open5
Fabrication and electrical integration of robust carbon nanotube micropillars by self-directed elastocapillary densification
Vertically-aligned carbon nanotube (CNT) "forest" microstructures fabricated
by chemical vapor deposition (CVD) using patterned catalyst films typically
have a low CNT density per unit area. As a result, CNT forests have poor bulk
properties and are too fragile for integration with microfabrication
processing. We introduce a new self-directed capillary densification method
where a liquid is controllably condensed onto and evaporated from CNT forests.
Compared to prior approaches, where the substrate with CNTs is immersed in a
liquid, our condensation approach gives significantly more uniform structures
and enables precise control of the CNT packing density and pillar
cross-sectional shape. We present a set of design rules and parametric studies
of CNT micropillar densification by this method, and show that self-directed
capillary densification enhances the Young's modulus and electrical
conductivity of CNT micropillars by more than three orders of magnitude. Owing
to the outstanding properties of CNTs, this scalable process will be useful for
the integration of CNTs as functional material in microfabricated devices for
mechanical, electrical, thermal, and biomedical applications
Micro-fabrication of Carbon Structures by Pattern Miniaturization in Resorcinol-Formaldehyde Gel
A simple and novel method to fabricate and miniaturize surface and
sub-surface micro-structures and micro-patterns in glassy carbon is proposed
and demonstrated. An aqueous resorcinol-formaldehyde (RF) sol is employed for
micro-molding of the master-pattern to be replicated, followed by controlled
drying and pyrolysis of the gel to reproduce an isotropically shrunk replica in
carbon. The miniaturized version of the master-pattern thus replicated in
carbon is about one order of magnitude smaller than original master by
repeating three times the above cycle of molding and drying. The
micro-fabrication method proposed will greatly enhance the toolbox for a facile
fabrication of a variety of Carbon-MEMS and C-microfluidic devices.Comment: 16 pages, 5 figure
Opportunities for mesoscopics in thermometry and refrigeration: Physics and applications
This review presents an overview of the thermal properties of mesoscopic
structures. The discussion is based on the concept of electron energy
distribution, and, in particular, on controlling and probing it. The
temperature of an electron gas is determined by this distribution:
refrigeration is equivalent to narrowing it, and thermometry is probing its
convolution with a function characterizing the measuring device. Temperature
exists, strictly speaking, only in quasiequilibrium in which the distribution
follows the Fermi-Dirac form. Interesting nonequilibrium deviations can occur
due to slow relaxation rates of the electrons, e.g., among themselves or with
lattice phonons. Observation and applications of nonequilibrium phenomena are
also discussed. The focus in this paper is at low temperatures, primarily below
4 K, where physical phenomena on mesoscopic scales and hybrid combinations of
various types of materials, e.g., superconductors, normal metals, insulators,
and doped semiconductors, open up a rich variety of device concepts. This
review starts with an introduction to theoretical concepts and experimental
results on thermal properties of mesoscopic structures. Then thermometry and
refrigeration are examined with an emphasis on experiments. An immediate
application of solid-state refrigeration and thermometry is in ultrasensitive
radiation detection, which is discussed in depth. This review concludes with a
summary of pertinent fabrication methods of presented devices.Comment: Close to the version published in RMP; 59 pages, 35 figure
- …