54 research outputs found

    Tip aerodynamics from wind tunnel test of semi-span wing

    Get PDF
    Presented are the results of a low-speed wind tunnel test on a 5.33-aspect-ratio, semi-span wing with 30- and 35 deg swept tapered tips. The test results include aerodynamic data for the tip itself and for the entire wing including the tip. The metric tip extended inboard 1.58 wing chord lengths. The aerodynamic drag data show the strong influence of tip incidence angle on tip drag for various lift levels. Pitching-moment characteristics show the effect of a moment center at 0.13 c and 0.25 c

    Alleviation of whirl-flutter on a joined-wing tilt-rotor aircraft configuration using active controls

    Get PDF
    The feasibility of using active controls to delay the onset of whirl-flutter on a joined-wing tilt rotor aircraft was investigated. The CAMRAD/JA code was used to obtain a set of linear differential equations which describe the motion of the joined-wing tilt-rotor aircraft. The hub motions due to wing/body motion is a standard input to CAMRAD/JA and were obtained from a structural dynamics model of a representative joined-wing tilt-rotor aircraft. The CAMRAD/JA output, consisting of the open-loop system matrices, and the airframe free vibration motion were input to a separate program which performed the closed-loop, active control calculations. An eigenvalue analysis was performed to determine the flutter stability of both open- and closed-loop systems. Sensor models, based upon the feedback of pure state variables and based upon hub-mounted sensors, providing physically measurable accelerations, were evaluated. It was shown that the onset of tilt-rotor whirl-flutter could be delayed from 240 to above 270 knots by feeding back vertical and span-wise accelerations, measured at the rotor hub, to the longitudinal cyclic pitch. Time response calculations at a 270-knot cruise condition showed an active cyclic pitch control level of 0.009 deg, which equates to a very acceptable 9 pound active-control force applied at the rotor hub

    A new design concept for indraft wind-tunnel inlets with application to the national full-scale aerodynamic complex

    Get PDF
    The present inlet design concept for an indraft wind tunnel, which is especially suited to applications for which a specific test section flow quality is required with minimum inlet size, employs a cascade or vaneset to control flow at the inlet plane, so that test section total pressure variation is minimized. Potential flow panel methods, together with empirical pressure loss predictions, are used to predict inlet cascade performance. This concept has been used to develop an alternative inlet design for the 80 x 120-ft wind tunnel at NASA Ames Research Center. Experimental results show that a short length/diameter ratio wind tunnel inlet furnishing atmospheric wind isolation and uniform test section flow can be designed

    Dynamic Calibration of the NASA Ames Rotor Test Apparatus Steady/Dynamic Rotor Balance

    Get PDF
    The NASA Ames Rotor Test Apparatus was modified to include a Steady/Dynamic Rotor Balance. The dynamic calibration procedures and configurations are discussed. Random excitation was applied at the rotor hub, and vibratory force and moment responses were measured on the steady/dynamic rotor balance. Transfer functions were computed using the load cell data and the vibratory force and moment responses from the rotor balance. Calibration results showing the influence of frequency bandwidth, hub mass, rotor RPM, thrust preload, and dynamic loads through the stationary push rods are presented and discussed

    Experimental study of flow deflectors designed to alleviate ground winds induced by exhaust of 80-by 120-foot wind tunnel

    Get PDF
    An experimental study directed at finding a deflector ramp that will reduce to an acceptable level the ground winds under the exhaust jet of the 80 by 120 Foot Wind Tunnel at NASA Ames Center is described. A one-fifieth scale model of the full-scale facility was used to investigate how the jet flow field was modified by the various design parameters of the ramp. It was concluded that the ground winds were alleviated sufficiently by a ramp with end plates located next to the wind tunnel building along the ground edge of the exhaust opening. At full scale, the ramp should have a slant length of 7.62 m (25 ft) or more, and would be elevated at about 45 degrees to the ground plane. The material should have holes less than 15.2 (6 in) in diameter distributed uniformly over its surface to produce a porosity of about 30%

    One-fiftieth scale model studies of 40-by 80-foot and 80-by 120-foot wind tunnel complex at NASA Ames Research Center

    Get PDF
    The features of a 1/50-scale model of the National Full-Scale Aerodynamics Complex are first described. An overview is then given of some results from the various tests conducted with the model to aid in the design of the full-scale facility. It was found that the model tunnel simulated accurately many of the operational characteristics of the full-scale circuits. Some characteristics predicted by the model were, however, noted to differ from previous full-scale results by about 10%

    Estimating Blade Section Airloads from Blade Leading-Edge Pressure Measurements

    No full text
    The Tilt-Rotor Aeroacoustic Model (TRAM) test in the Duitse-Nederlandse Wind (DNW) Tunnel acquired blade pressure data for forward flight test conditions of a tiltrotor in helicopter mode. Chordwise pressure data at seven radial locations were integrated to obtain the blade section normal force. The present investigation evaluates the use of linear regression analysis and of neural networks in estimating the blade section normal force coefficient from a limited number of blade leading-edge pressure measurements and representative operating conditions. These network models are subsequently used to estimate the airloads at intermediate radial locations where only blade pressure measurements at the 3.5% chordwise stations are available

    Preliminary Sizing of 120-Passenger Advanced Civil Rotorcraft Concepts

    No full text
    The results of a preliminary sizing study of advanced civil rotorcraft concepts that are capable of carrying 120 passengers over a range of 1,200 nautical miles are presented. The cruise altitude of these rotorcraft is 30,000 ft and the cruise velocity is 350 knots. The mission requires a hover capability, creating a runway independent solution, which might aid in reducing strain on the existing airport infrastructure. Concepts studied are a tiltrotor, a tandem rotor compound, and an advancing blade concept. The first objective of the study is to determine the relative merits of these designs in terms of mission gross weight, engine size, fuel weight, aircraft purchase price, and direct operating cost. The second objective is to identify the enabling technology for these advanced heavy lift civil rotorcraft

    Improved diagnostic prediction of the pathogenicity of bloodstream isolates of Staphylococcus epidermidis.

    No full text
    With an estimated 440,000 active cases occurring each year, medical device associated infections pose a significant burden on the US healthcare system, costing about $9.8 billion in 2013. Staphylococcus epidermidis is the most common cause of these device-associated infections, which typically involve isolates that are multi-drug resistant and possess multiple virulence factors. S. epidermidis is also frequently a benign contaminant of otherwise sterile blood cultures. Therefore, tests that distinguish pathogenic from non-pathogenic isolates would improve the accuracy of diagnosis and prevent overuse/misuse of antibiotics. Attempts to use multi-locus sequence typing (MLST) with machine learning for this purpose had poor accuracy (~73%). In this study we sought to improve the diagnostic accuracy of predicting pathogenicity by focusing on phenotypic markers (i.e., antibiotic resistance, growth fitness in human plasma, and biofilm forming capacity) and the presence of specific virulence genes (i.e., mecA, ses1, and sdrF). Commensal isolates from healthy individuals (n = 23), blood culture contaminants (n = 21), and pathogenic isolates considered true bacteremia (n = 54) were used. Multiple machine learning approaches were applied to characterize strains as pathogenic vs non-pathogenic. The combination of phenotypic markers and virulence genes improved the diagnostic accuracy to 82.4% (sensitivity: 84.9% and specificity: 80.9%). Oxacillin resistance was the most important variable followed by growth rate in plasma. This work shows promise for the addition of phenotypic testing in clinical diagnostic applications
    • …
    corecore