78 research outputs found

    Supplementation of Holstein dairy calves fed two levels of crude protein with methionine and lysine

    Get PDF
    This study aimed to investigate various levels of crude protein (CP) in starter diets and their supplementation with amino acids (AAs) on efficiency, health, and serum metabolites of dairy calves. Ninety-six newborn Holstein calves were allocated to eight treatments, namely T1) 18% CP unsupplemented starter, T2) T1 supplemented with additional 20% methionine, T3) T1 with additional 20% lysine and 20% methionine, T4) T1 with additional 20% lysine, T5) 22% CP unsupplemented starter, T6) T5 supplemented with additional 20% methionine, T7) T5 supplemented with additional 20% lysine and 20% methionine, and T8) T5 supplemented with additional 20% lysine. Consumption of the starter was not influenced by the level of CP. Calves that received the unsupplemented 22% CP starter had higher average daily gain (ADG) and final weight. But no significant differences among diets were found in feed efficiency. Skeletal growth did not exhibit a clear trend. Calves that received T3 had fewer bouts of diarrhea and reduced body temperature. However, there were no significant dietary effects on immunoglobin G (IgG) or total protein concentration in blood. T1–T3 decreased serum urea concentration. Thus, use of T3 resulted in an improved amino acid balance, and was less expensive than the 22% CP starter.Keywords: amino acid, feed intake, immunity, pre-ruminant cal

    OPTIMAL BAND RATIO ANALYSIS OF WORLDVIEW-3 IMAGERY FOR BATHYMETRY OF SHALLOW RIVERS (CASE STUDY: SARCA RIVER, ITALY)

    Get PDF
    The Optimal Band Ratio Analysis (OBRA) could be considered as an efficient technique for bathymetry from optical imagery due to its robustness on substrate variability. This point receives more attention for very shallow rivers where different substrate types can contribute remarkably into total at-sensor radiance. The OBRA examines the total possible pairs of spectral bands in order to identify the optimal two-band ratio that its log transformation yields a strong linear relation with field measured water depths. This paper aims at investigating the effectiveness of additional spectral bands of newly launched WorldView-3 (WV-3) imagery in the visible and NIR spectrum through OBRA for retrieving water depths in shallow rivers. In this regard, the OBRA is performed on a WV-3 image as well as a GeoEye image of a small Alpine river in Italy. In-situ depths are gathered in two river reaches using a precise GPS device. In each testing scenario, 50% of the field data is used for calibration of the model and the remained as independent check points for accuracy assessment. In general, the effect of changes in water depth is highly pronounced in longer wavelengths (i.e. NIR) due to high and rapid absorption of light in this spectrum as long as it is not saturated. As the studied river is shallow, NIR portion of the spectrum has not been reduced so much not to reach the riverbed; making use of the observed radiance over this spectral range as denominator has shown a strong correlation through OBRA. More specifically, tightly focused channels of red-edge, NIR-1 and NIR-2 provide a wealth of choices for OBRA rather than a single NIR band of conventional 4-band images (e.g. GeoEye). This advantage of WV-3 images is outstanding as well for choosing the optimal numerator of the ratio model. Coastal-blue and yellow bands of WV-3 are identified as proper numerators while only green band of the GeoEye image contributed to a reliable correlation of image derived values and field measured depths. According to the results, the additional and narrow spectral bands of WV-3 image lead to an average determination coefficient of 67% in two river segments, which is 10% higher than that of obtained from the 4-band GeoEye image. In addition, RMSEs of depth estimations are calculated as 4 cm and 6 cm respectively for WV-3 and GeoEye images, considering the optimal band ratio.</jats:p

    Nasal continuous positive airway pressure improves myocardial perfusion reserve and endothelial-dependent vasodilation in patients with obstructive sleep apnea

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Obstructive sleep apnea (OSA) has been associated with cardiovascular disease (CVD), but whether OSA is an independent risk factor for CVD is controversial. The purpose of this study is to determine if patients with OSA have subclinical cardiovascular disease that is detectable by multi-modality cardiovascular imaging and whether these abnormalities improve after nasal continuous positive airway pressure (nCPAP).</p> <p>Results</p> <p>Of the 35 consecutive subjects with newly diagnosed moderate to severe OSA recruited from the Stanford Sleep Disorders Clinic, 20 patients were randomized to active vs. sham nCPAP. Active nCPAP was titrated to pressures that would prevent sleep disordered breathing based on inpatient polysomnography. OSA patients had baseline vascular function abnormalities including decreased myocardial perfusion reserve (MPR), brachial flow mediated dilation (FMD) and nitroglycerin-induced coronary vasodilation. Patients randomized to active nCPAP had improvement of MPR (1.5 ± 0.5 vs. 3.0 ± 1.3, p = 0.02) and brachial FMD (2.5% ± 5.7% vs. 9.0% ± 6.5%, p = 0.03) after treatment, but those randomized to sham nCPAP showed no significant improvement. There were no significant changes seen in chamber sizes, systolic and diastolic function, valvular function and coronary vasodilation to nitroglycerin.</p> <p>Conclusions</p> <p>Patients with moderate to severe OSA had decreased MPR and brachial FMD that improved after 3 months of nCPAP. These findings suggest that relief of apnea in OSA may improve microvascular disease and endothelial dysfunction, which may prevent the development of overt cardiovascular disease. Further study in a larger patient population may be warranted.</p

    Diagnostic accuracy of a clinical diagnosis of idiopathic pulmonary fibrosis: An international case-cohort study

    Get PDF
    We conducted an international study of idiopathic pulmonary fibrosis (IPF) diagnosis among a large group of physicians and compared their diagnostic performance to a panel of IPF experts. A total of 1141 respiratory physicians and 34 IPF experts participated. Participants evaluated 60 cases of interstitial lung disease (ILD) without interdisciplinary consultation. Diagnostic agreement was measured using the weighted kappa coefficient (\u3baw). Prognostic discrimination between IPF and other ILDs was used to validate diagnostic accuracy for first-choice diagnoses of IPF and were compared using the Cindex. A total of 404 physicians completed the study. Agreement for IPF diagnosis was higher among expert physicians (\u3baw=0.65, IQR 0.53-0.72, p20 years of experience (C-index=0.72, IQR 0.0-0.73, p=0.229) and non-university hospital physicians with more than 20 years of experience, attending weekly MDT meetings (C-index=0.72, IQR 0.70-0.72, p=0.052), did not differ significantly (p=0.229 and p=0.052 respectively) from the expert panel (C-index=0.74 IQR 0.72-0.75). Experienced respiratory physicians at university-based institutions diagnose IPF with similar prognostic accuracy to IPF experts. Regular MDT meeting attendance improves the prognostic accuracy of experienced non-university practitioners to levels achieved by IPF experts

    OPTIMAL BAND RATIO ANALYSIS OF WORLDVIEW-3 IMAGERY FOR BATHYMETRY OF SHALLOW RIVERS (CASE STUDY: SARCA RIVER, ITALY)

    No full text
    The Optimal Band Ratio Analysis (OBRA) could be considered as an efficient technique for bathymetry from optical imagery due to its robustness on substrate variability. This point receives more attention for very shallow rivers where different substrate types can contribute remarkably into total at-sensor radiance. The OBRA examines the total possible pairs of spectral bands in order to identify the optimal two-band ratio that its log transformation yields a strong linear relation with field measured water depths. This paper aims at investigating the effectiveness of additional spectral bands of newly launched WorldView-3 (WV-3) imagery in the visible and NIR spectrum through OBRA for retrieving water depths in shallow rivers. In this regard, the OBRA is performed on a WV-3 image as well as a GeoEye image of a small Alpine river in Italy. In-situ depths are gathered in two river reaches using a precise GPS device. In each testing scenario, 50% of the field data is used for calibration of the model and the remained as independent check points for accuracy assessment. In general, the effect of changes in water depth is highly pronounced in longer wavelengths (i.e. NIR) due to high and rapid absorption of light in this spectrum as long as it is not saturated. As the studied river is shallow, NIR portion of the spectrum has not been reduced so much not to reach the riverbed; making use of the observed radiance over this spectral range as denominator has shown a strong correlation through OBRA. More specifically, tightly focused channels of red-edge, NIR-1 and NIR-2 provide a wealth of choices for OBRA rather than a single NIR band of conventional 4-band images (e.g. GeoEye). This advantage of WV-3 images is outstanding as well for choosing the optimal numerator of the ratio model. Coastal-blue and yellow bands of WV-3 are identified as proper numerators while only green band of the GeoEye image contributed to a reliable correlation of image derived values and field measured depths. According to the results, the additional and narrow spectral bands of WV-3 image lead to an average determination coefficient of 67% in two river segments, which is 10% higher than that of obtained from the 4-band GeoEye image. In addition, RMSEs of depth estimations are calculated as 4 cm and 6 cm respectively for WV-3 and GeoEye images, considering the optimal band ratio

    Microsoft Word - 4رزم آرايي

    No full text

    Microsoft Word - 6راضي جلالي.doc

    No full text

    Two-phase flow measurement system for polymer electrolyte fuel cells

    No full text
    In this paper, a sensory system capable of measuring two-phase flow of water at the PEFC output is introduced. It works based on collecting and evaporating the liquid water that exits the PEFC in a vessel that is heated to a temperature above that of the fuel cell temperature. By measuring the vessel dew point temperature and flow rate, the mass of water in liquid and vapor phases are calculated. To demonstrate the capabilities of this measurement system, it is placed at the output of a PEFC cathode during membrane conditioning. The effect of two-phase flow on cell voltage reveals two distinct modes of liquid water transport in the PEFC cathode during membrane conditioning. © 2009 Elsevier B.V. All rights reserved
    corecore