437 research outputs found

    The O-type eclipsing binary SZ Cam revisited

    Full text link
    We analyse new spectra of the multiple system SZ Cam because previous studies found different values of the primary radial velocity amplitude. The older solutions of light curves also have different ratios of secondary to primary luminosity as inferred from the observed equivalent widths of spectral lines. We therefore reanalyse the light curves of the eclipsing pair. Only the light curve derived by Wesselink has a solution that agrees with the observed equivalent width ratio. The resulting parameters of the binary are discussed. Masses of M1=16.6M_1=16.6 and M2=11.9M_2=11.9 M_{\odot}, and radii R1=9.4R_1=9.4 and R2=5.4R_2=5.4 R_{\odot} are derived. We point out that radial velocities measured with the CCF method can be misleading when the method is applied to multiple systems with complex line blends. New radial velocities are also obtained for the visual component ADS 2984 A (HD 25639).Comment: Astronomy and Astrophysics, accepte

    Хірургічне лікування хордоми крижів

    Get PDF
    Мета. Аналіз хірургічної техніки, результатів хірургічного та комбінованого лікування хордоми крижів. Матеріали і методи. У 28 хворих з хордомами крижів проаналізовано симптоми захворювання та їх динаміку, цін- ність методів нейровізуалізації, особливості патогістологічної картини, хірургічну техніку, ефективність променевої те- рапії та віддалені результати лікування. Результати. Серед клінічних проявів хордоми крижів домінував больовий синдром. Середня тривалість анамнезу ста- новила близько одного року. Хірургічну резекцію пухлини через задній доступ виконали 18 хворим, через комбінова- ний – 9 хворим. Видалення пухлин оцінене як радикальне у 21 хворого, часткове – у 7 хворих. У післяопераційному періоді всім хворим проведено курс променевої терапії на лінійному прискорювачі. Протягом 5 років у 26 хворих ви- ник рецидив хордоми. Повторне оперативне втручання виконали 22 хворим. Висновки. Лікування хордом потребує комплексного підходу. Методом вибору залишається виконання радикального хірургічного втручання, що можливо не у всіх хворих

    On the orbital and physical parameters of the HDE 226868/Cygnus X-1 binary system

    Full text link
    In this paper we explore the consequences of the recent determination of the mass m=(8.7 +/- 0.8)M_Sun of Cygnus X-1, obtained from the Quasi-Periodic Oscillation (QPO)-photon index correlation scaling, on the orbital and physical properties of the binary system HDE 226868/Cygnus X-1. By using such a result and the latest spectroscopic optical data of the HDE 226868 supergiant star we get M=(24 +/- 5)M_Sun for its mass. It turns out that deviations from the third Kepler law significant at more than 1-sigma level would occur if the inclination i of the system's orbital plane to the plane of the sky falls outside the range 41-56 deg: such deviations cannot be due to the first post-Newtonian (1PN) correction to the orbital period because of its smallness; interpreted in the framework of the Newtonian theory of gravitation as due to the stellar quadrupole mass moment Q, they are unphysical because Q would take unreasonably large values. By conservatively assuming that the third Kepler law is an adequate model for the orbital period we obtain i=(48 +/- 7) deg which yields for the relative semimajor axis a=(42 +/- 9)R_Sun. Our estimate for the Roche's lobe of HDE 226868 is r_M = (21 +/- 6)R_Sun.Comment: Latex2e, 7 pages, 1 table, 4 figures. To appear in ApSS (Astrophysics and Space Science

    ВНЕЛАБОРАТОРНЫЙ ЭКСПРЕССНЫЙ ГАЗОХРОМАТОГРАФИЧЕСКИЙ МЕТОД АНАЛИЗА ВЫДЫХАЕМОГО ЧЕЛОВЕКОМ ВОЗДУХА С АВТОМАТИЗИРОВАННОЙ ГРАДУИРОВКОЙ

    Get PDF
    One of the current urgent task in medicine, and preventive medicine in particular, is the development of noninvasive (without surgery) methods of diagnosis and determination of the risks of various diseases. Much attention is paid to the possibilities of exhaled breath analysis for the diagnosis of various diseases such as cancer, gastroenterology, diabetes and others. Possibilities of such analyses are determined by a wide range of human exhaled volatile organic compounds. The growing interest in the development of noninvasive methods of diagnosis of diseases by the analysis of exhaled breath initiated the creation of easy-to-use and portable gas analyzers for the mass examination of patients in non-laboratory conditions. The main requirements for such gas analyzers are combinations of portability, speed, sensitivity and stability control. Current article presents a gas chromatographic method of rapid analysis of exhaled breath with an automated calibration of the vapor-phase concentration source that meets all of the above requirements. A portable polycapillary gas chromatography is used, which provides low thresholds for the determination of substances at the time of analysis of a few tens of seconds. The method of obtaining the vapor-phase calibration concentration of acetone vapors at the level of 10-10 g/cm3 is discussed. The calibration unit is integrated into the gas chromatograph (GC), and its software control ensures the automation of GC calibration. The original scheme of the sampling system (SS) provides multiple input samples from a single exhalation of a person and a completely similar input calibration air mixture in GC to reduce the calibration errors. The structure of the software is implemented in convenient terms for the chemist-analyst practice. Original SS, polycapillary gas chromatography, and built-in automated calibration provide real-time analysis of exhaled air in the presence of the patient. The possibility of differentiation of patients by metabolic disorders (metabolism) in the human body by express analysis of exhaled air using the proposed gas chromatographic method of express analysis of exhaled air with automated calibration is illustrated.Key words: automated sample device, express analysis of exhaled air, polycapillary gas chromatography, automated graduation, a head-space source of concentration(Russian) DOI: http://dx.doi.org/10.15826/analitika.2018.22.2.007A.O. Malysheva1, 3, M.N. Baldin1, V.M. Gruznov1, 2, 3, L.V. Blinova11Trofimuk Institute of Petroleum Geology and Geophysics of Siberian Branch of Russian Academy of Sciences, Koptyug Avenue, 3, Novosibirsk, 630090,Russian Federation 2Novosibirsk State University, Pirogova St., 2, Novosibirsk, 630090, Russian Federation 3Novosibirsk State Technical University, K. Marx Avenue, 20, Novosibirsk, 630073, Russian FederationВ настоящее время актуальной задачей медицины, в частности профилактической, является разработка неинвазивных (бескровных) методик диагностики и определения риска различных заболеваний. Уделяется большое внимание возможностям анализа выдыхаемого воздуха для диагностики различных заболеваний – раковых, гастроэнтерологических, сахарного диабета и других. Возможности такого анализа определены широким набором выдыхаемых человеком летучих органических соединений. Возрастающий интерес к разработке неинвазивных методик диагностики заболеваний по анализу выдыхаемого человеком воздуха инициирует создание простых в обращении и портативных газовых анализаторов для массового обследования пациентов во внелабораторных условиях. Основные требования к газоанализаторам ‒ это сочетание портативности, быстродействия, чувствительности и контроля стабильности отклика. В статье изложен удовлетворяющий этим требованиям газохроматографический метод экспрессного анализа выдыхаемого воздуха с автоматизированной градуировкой парофазным источником концентрации. Использована портативная поликапиллярная газовая хроматография, обеспечивающая низкие пороги определения веществ при времени анализа в несколько десятков секунд. Обсуждается методика получения парофазной градуировочной концентрации паров ацетона на уровне 10–10 г/см3. Блок градуировки встроен в газовый хроматограф (ГХ), его программное управление обеспечивает автоматизацию градуировки ГХ. Оригинальная схема пробоотборного устройства (ПУ) обеспечивает многократный ввод пробы из разового выдоха человека и полностью аналогичный ввод градуировочной воздушной смеси в ГХ для уменьшения погрешностей градуировки. Структура программного обеспечения (ПО) реализована в терминах, удобных для практики химика-аналитика. Оригинальное ПУ, поликапиллярная газовая хроматография, встроенная автоматизированная градуировка обеспечивают анализ выдыхаемого воздуха в режиме реального времени в присутствии пациента. Проиллюстрирована возможность дифференцирования пациентов по нарушению метаболизма (обмену веществ) в организме человека по экспрессному анализу выдыхаемого воздуха предложенным газохроматографическим методом экспрессного анализа выдыхаемого воздуха с автоматизированной градуировкой.Ключевые слова: отбор выдыхаемого воздуха, экспрессный анализ выдыхаемого воздуха, поликапиллярная газовая хроматография, автоматизированная градуировка, парофазный источник концентрацииDOI: http://dx.doi.org/10.15826/analitika.2018.22.2.00

    Self-trapped states and the related luminescence in PbCl2_2 crystals

    Get PDF
    We have comprehensively investigated localized states of photoinduced electron-hole pairs with electron-spin-resonance technique and photoluminescence (PL) in a wide temperature range of 5-200 K. At low temperatures below 70 K, holes localize on Pb2+^{2+} ions and form self-trapping hole centers of Pb3+^{3+}. The holes transfer to other trapping centers above 70 K. On the other hand, electrons localize on two Pb2+^{2+} ions at higher than 50 K and form self-trapping electron centers of Pb2_23+^{3+}. From the thermal stability of the localized states and PL, we clarify that blue-green PL band at 2.50 eV is closely related to the self-trapped holes.Comment: 8 pages (10 figures), ReVTEX; removal of one figure, Fig. 3 in the version
    corecore