86 research outputs found

    The Impact of an Accurate Vertical Localization with HRTFs on Short Explorations of Immersive Virtual Reality Scenarios

    Get PDF
    Achieving a full 3D auditory experience with head-related transfer functions (HRTFs) is still one of the main challenges of spatial audio rendering. HRTFs capture the listener's acoustic effects and personal perception, allowing immersion in virtual reality (VR) applications. This paper aims to investigate the connection between listener sensitivity in vertical localization cues and experienced presence, spatial audio quality, and attention. Two VR experiments with head-mounted display (HMD) and animated visual avatar are proposed: (i) a screening test aiming to evaluate the participants' localization performance with HRTFs for a non-visible spatialized audio source, and (ii) a 2 minute free exploration of a VR scene with five audiovisual sources in a both non-spatialized (2D stereo panning) and spatialized (free-field HRTF rendering) listening conditions. The screening test allows a distinction between good and bad localizers. The second one shows that no biases are introduced in the quality of the experience (QoE) due to different audio rendering methods; more interestingly, good localizers perceive a lower audio latency and they are less involved in the visual aspects

    Virtual Reality Exploration with Different Head-Related Transfer Functions

    Get PDF
    One of the main challenges of spatial audio rendering in headphones is the crucial work behind the personalization of the so-called head-related transfer functions (HRTFs). HRTFs capture the listener's acoustic effects allowing a personal perception of immersion in virtual reality context. This paper aims to investigate the possible benefits of personalized HRTFs that were individually selected based on anthropometric data (pinnae shapes). Personalized audio rendering was compared to a generic HRTF and a stereo sound condition. Two studies were performed; the first study consisted of a screening test aiming to evaluate the participants' localization performance with HRTFs for a non-visible spatialized audio source. The second experiment allowed the participants to freely explore a VR scene with five audiovisual sources for two minutes each, with both HRTF and stereo conditions. A questionnaire with items for spatial audio quality, presence and attention was used for the evaluation. Results indicate that audio rendering methods made no difference on responses to the questionnaire in the two minutes of a free exploration

    Torsional stability of interference screws derived from bovine bone - a biomechanical study

    Get PDF
    Introduction: It has been proposed that individual genetic variation contributes to the course of severe infections and sepsis. Recent studies of single nucleotide polymorphisms (SNPs) within the endotoxin receptor and its signaling system showed an association with the risk of disease development. This study aims to examine the response associated with genetic variations of TLR4, the receptor for bacterial LPS, and a central intracellular signal transducer (TIRAP/Mal) on cytokine release and for susceptibility and course of severe hospital acquired infections in distinct patient populations. Methods: Three intensive care units in tertiary care university hospitals in Greece and Germany participated. 375 and 415 postoperative patients and 159 patients with ventilator associated pneumonia (VAP) were included. TLR4 and TIRAP/Mal polymorphisms in 375 general surgical patients were associated with risk of infection, clinical course and outcome. In two prospective studies, 415 patients following cardiac surgery and 159 patients with newly diagnosed VAP predominantly caused by Gram-negative bacteria were studied for cytokine levels in-vivo and after ex-vivo monocyte stimulation and clinical course. Results: Patients simultaneously carrying polymorphisms in TIRAP/Mal and TLR4 and patients homozygous for the TIRAP/Mal SNP had a significantly higher risk of severe infections after surgery (odds ratio (OR) 5.5; confidence interval (CI): 1.34 - 22.64; P = 0.02 and OR: 7.3; CI: 1.89 - 28.50; P < 0.01 respectively). Additionally we found significantly lower circulating cytokine levels in double-mutant individuals with ventilator associated pneumonia and reduced cytokine production in an ex-vivo monocyte stimulation assay, but this difference was not apparent in TIRAP/Mal-homozygous patients. In cardiac surgery patients without infection, the cytokine release profiles were not changed when comparing different genotypes. Conclusions: Carriers of mutations in sequential components of the TLR signaling system may have an increased risk for severe infections. Patients with this genotype showed a decrease in cytokine release when infected which was not apparent in patients with sterile inflammation following cardiac surgery

    Feasibility studies for the measurement of time-like proton electromagnetic form factors from p¯ p→ μ+μ- at P ¯ ANDA at FAIR

    Get PDF
    This paper reports on Monte Carlo simulation results for future measurements of the moduli of time-like proton electromagnetic form factors, | GE| and | GM| , using the p¯ p→ μ+μ- reaction at P ¯ ANDA (FAIR). The electromagnetic form factors are fundamental quantities parameterizing the electric and magnetic structure of hadrons. This work estimates the statistical and total accuracy with which the form factors can be measured at P ¯ ANDA , using an analysis of simulated data within the PandaRoot software framework. The most crucial background channel is p¯ p→ π+π-, due to the very similar behavior of muons and pions in the detector. The suppression factors are evaluated for this and all other relevant background channels at different values of antiproton beam momentum. The signal/background separation is based on a multivariate analysis, using the Boosted Decision Trees method. An expected background subtraction is included in this study, based on realistic angular distributions of the background contribution. Systematic uncertainties are considered and the relative total uncertainties of the form factor measurements are presented

    New Concepts in External Fixation of the Lower Leg a Biomechanical Study

    No full text
    • …
    corecore