32 research outputs found

    Conjugal transfer of R68.45 and FP5 between Pseudomonas aeruginosa strains in a freshwater environment

    Get PDF
    Recent concern over the release of genetically engineered organisms has resulted in a need for information about the potential for gene transfer in the environment. In this study, the conjugal transfer in Pseudomonas aeruginosa of the plasmids R68.45 and FP5 was demonstrated in the freshwater environment of Fort Loudoun Resevoir, Knoxville, Tenn. When genetically well defined plasmid donor and recipient strains were introduced into test chambers suspended in Fort Loudoun Lake, transfer of both plasmids was observed. Conjugation occurred in both the presence and absence of the natural microbial community. The number of transconjugants recovered was lower when the natural community was present. Transfer of the broad-host-range plasmid R68.45 to organisms other than the introduced recipient was not observed in these chambers but was observed in laboratory simulations when an organism isolated from lakewater was used as the recipient strain. Although the plasmids transferred in laboratory studies were genetically and physically stable, a significant number of transconjugants recovered from the field trials contained deletions and other genetic rearrangements, suggesting that factors which increase gene instability are operating in the environment. The potential for conjugal transfer of genetic material must be considered in evaluating the release of any genetically engineered microorganism into a freshwater environment.Peer reviewedMicrobiology and Molecular Genetic

    Isolation of  -Amyrin from the Fungus Aspergillus nidulans

    No full text

    "Resonances" in the dielectric absorption of DNA?

    Get PDF
    An attempt was made to confirm previous reports of resonant-like dielectric absorption of plasmid DNA in aqueous solutions at 1-10 GHz. The dielectric properties of the sample were measured using an automatic network analyzer with two different techniques. One technique used an open-ended coaxial probe immersed in the sample; the other employed a coaxial transmission line. No resonances were observed that could be attributed to the sample; however, resonance-type artifacts were prominent in the probe measurements. The coaxial line technique appears to be less susceptible to such artifacts. We note two important sources of error in the calibration of the automatic network analyzer using the probe technique
    corecore