1,172 research outputs found

    Solar models and solar neutrino oscillations

    Get PDF
    We provide a summary of the current knowledge, theoretical and experimental, of solar neutrino fluxes and of the masses and mixing angles that characterize solar neutrino oscillations. We also summarize the principal reasons for doing new solar neutrino experiments and what we think may be learned from the future measurements.Comment: Submitted to the Neutrino Focus Issue of New Journal of Physics at http://www.njp.or

    Successful oxytocin-assisted nipple aspiration in women at increased risk for breast cancer

    Get PDF
    The high rate of interval malignancies urges for new screening methods for women at high risk for breast cancer. Nipple aspiration provides direct access to the breast tissue and its DNA, and therefore is a likely candidate, but clinical applications have been limited by the failure to obtain nipple aspiration fluid from most women. We performed oxytocin-assisted nipple aspiration in 90 women at increased risk for breast cancer based on family history or genetic test results (n = 63) and/or previous breast cancer (n = 34). Nipple fluid was obtained from 81/90 women (90%) and bilaterally in 77%. Mean discomfort rating was 0.6 (on a 0–10 scale), which was significantly lower than for mammography or MRI. These findings suggest that a new tool for biomarker detection in oxytocin-assisted nipple fluid of women at high risk for breast cancer is at hand

    Evaluation of a spring-powered captive bolt gun for killing kangaroo pouch young

    Get PDF
    Context: During commercial harvesting or non-commercial kangaroo culling programs, dependent young of shot females are required to be euthanased to prevent suffering and because they would be unlikely to survive. However, the current method for killing pouch young, namely a single, forceful blow to the base of the skull, is applied inconsistently by operators and perceived by the public to be inhumane. Aims: To determine whether an alternative method for killing pouch young, namely a spring-operated captive bolt gun, is effective at causing insensibility in kangaroo pouch young. Methods: Trials of spring-operated captive bolt guns were conducted first on the heads of 15 dead kangaroo young and then on 21 live pouch young during commercial harvesting. We assessed the effectiveness at causing insensibility in live animals and damage caused to specific brain areas. We also measured depth of bolt penetration and skull thickness. Performance characteristics (e.g. bolt velocity) of two types of spring-operated guns were also measured and compared with cartridge-powered devices. Key results: When tested on the heads of dead animals, the spring-operated captive bolt gun consistently produced a large entrance cavity and a well defined wound tract, which extended into the cerebrum, almost extending the full thickness of the brain, including the brainstem. When tested on live pouch young, the captive bolt gun caused immediate insensibility in only 13 of 21 animals. This 62% success rate is significantly below the 95% minimum acceptable threshold for captive bolt devices in domestic animal abattoirs. Failure to stun was related to bolt placement, but other factors such as bolt velocity, bolt diameter and skull properties such as thickness and hardness might have also contributed. Spring-operated captive bolt guns delivered 20 times less kinetic energy than did cartridge-powered devices. Conclusions: Spring-operated captive bolt guns cannot be recommended as an acceptable or humane method for stunning or killing kangaroo pouch young. Implications: Captive bolt guns have potential as a practical alternative to blunt head trauma for effective euthanasia and reducing animal (and observer) distress. However, operators must continue to use the existing prescribed killing methods until cartridge-powered captive bolt guns have been trialled as an alternative bolt propelling method. Additional keywords: animal welfare, blunt trauma, culling, euthanasia, humaneness, kangaroo harvesting

    Designing the ideal model for assessment of wound contamination after gunshot injuries: a comparative experimental study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Modern high-velocity projectiles produce temporary cavities and can thus cause extensive tissue destruction along the bullet path. It is still unclear whether gelatin blocks, which are used as a well-accepted tissue simulant, allow the effects of projectiles to be adequately investigated and how these effects are influenced by caliber size.</p> <p>Method</p> <p>Barium titanate particles were distributed throughout a test chamber for an assessment of wound contamination. We fired .22-caliber Magnum bullets first into gelatin blocks and then into porcine hind limbs placed behind the chamber. Two other types of bullets (.222-caliber bullets and 6.5 × 57 mm cartridges) were then shot into porcine hind limbs. Permanent and temporary wound cavities as well as the spatial distribution of barium titanate particles in relation to the bullet path were evaluated radiologically.</p> <p>Results</p> <p>A comparison of the gelatin blocks and hind limbs showed significant differences (<it>p </it>< 0.05) in the mean results for all parameters. There were significant differences between the bullets of different calibers in the depth to which barium titanate particles penetrated the porcine hind limbs. Almost no particles, however, were found at a penetration depth of 10 cm or more. By contrast, gas cavities were detected along the entire bullet path.</p> <p>Conclusion</p> <p>Gelatin is only of limited value for evaluating the path of high-velocity projectiles and the contamination of wounds by exogenous particles. There is a direct relationship between the presence of gas cavities in the tissue along the bullet path and caliber size. These cavities, however, are only mildly contaminated by exogenous particles.</p

    Similarities and differences between the E5 oncoproteins of bovine papillomaviruses type 1 and type 4: Cytoskeleton, motility and invasiveness in E5-transformed bovine and mouse cells

    Get PDF
    Bovine papillomaviruses (BPVs) are oncogenic viruses. In cattle, BPV-1/2 is associated with urinary bladder cancer and BPV-4 with upper GI tract cancer. BPV E5 is a small hydrophobic protein localised in the endoplasmic reticulum (ER) and Golgi apparatus (GA). E5 is the major transforming protein of BPVs, capable of inducing cell transformation in cultured mouse fibroblasts and, in cooperation with E7, in primary bovine cells. E5-induced cell transformation is accompanied by activation of several cellular protein kinases, including growth factor receptors, and alkalinisation of endosomes and GA. We have reported that BPV E5 causes swelling and fragmentation of the GA and extensive vacuolisation of the cytoplasm. We now show that E5 from both BPV-1 and BPV-4 disturbs the actin cytoskeleton and focal adhesions in transformed bovine cells, where these morphological and behavioural characteristics are accompanied by hyperphosphorylation of the cellular phosphotyrosine kinase c-src. Both BPV-1 and BPV-4 E5 increase the motility of transformed mouse cells, but only BPV-1 E5 causes transformed mouse cells to penetrate a matrigel matrix. BPV-1 transformed mouse cells, but not BPV-4 transformed mouse cells, have hyperhpsphorylated c-src
    corecore