90 research outputs found

    Shunt Hybrid Active Power Filter Based on Two Compensation Strategies with PI and Fuzzy Logic Controllers

    Get PDF
    Industrial designs have tremendously changed within the last decade, with its time and nonlinear variation loads in power frameworks spectrum expanding widely. This revolution has resulted in increased quality control problems such as current unbalance, current and voltage harmonics, flicker and poor power factor in control frameworks. The aim of this paper is to address this problem through the development of Synchronous Reference Frame and Reactive Power (SRF and P-Q) control methods. The DC voltage was regulated to its set reference for providing the current reference using proportional-Integral (PI) and fuzzy logic controllers. From the results, Fuzzy logic control was shown to achieve an adequate DC capacitor energy storage optimization, the sinusoidal type of the current and the change of the power factor. A low Total Harmonic Distortion (THD) that met the suggestions of IEEE- 519 standard on symphonious levels was achieved with the proposed method

    Mutations in DSTYK and dominant urinary tract malformations.

    Get PDF
    ABSTRACT Introduction Congenital abnormalities of the kidney of the urinary tract are the most common cause of pediatric kidney failure. These disorders are highly heterogeneous, and their etiology is poorly understood. Methods We performed genome-wide linkage analysis and whole-exome sequencing in a family with autosomal dominant congenital abnormalities of the kidney of the urinary tract (7 affected family members). We also performed sequence analysis in 311 unrelated patients, as well as histologic and functional studies. Results Linkage analysis identified five regions of the genome that were shared among all affected family members. Exome sequencing identified a single rare deleterious variant within these linkage intervals, a heterozygous splice-site mutation in dual serine/threonine and tyrosine protein kinase (DSTYK). This variant, which resulted in aberrant gene product splicing, was present in all affected family members. Additional independent DSTYK mutations, including nonsense and splice-site mutations, were detected among 7/311 unrelated patients. DSTYK is highly expressed in the maturing epithelia of all major organs, localizing to cell membranes. Knockdown in zebrafish resulted in multi-organ developmental defects, resembling loss of fibroblast growth factor (FGF) signaling. Consistent with this finding, DSTYK colocalizes with FGF receptors in the ureteric bud and metanephric mesenchyme. Finally, DSTYK knockdown in human embryonic kidney cells inhibited FGF-stimulated ERK-phosphorylation, the principal signal downstream of receptor tyrosine kinases. Conclusions We detected DSTYK mutations in 2.2% of patients with congenital abnormalities of the kidney and urinary tract whom we studied, suggesting that DSTYK is a major determinant of human urinary tract development, downstream of FGF signaling

    Golimumab

    No full text

    Shunt hybrid active power filter based on two compensation strategies with PI and fuzzy logic controllers

    Get PDF
    Industrial designs have tremendously changed within the last decade, with its time and nonlinear variation loads in power frameworks spectrum expanding widely. This revolution has resulted in increased quality control problems such as current unbalance, current and voltage harmonics, flicker and poor power factor in control frameworks. The aim of this paper is to address this problem through the development of Synchronous Reference Frame and Reactive Power (SRF and P-Q) control methods. The DC voltage was regulated to its set reference for providing the current reference using proportional-Integral (PI) and fuzzy logic controllers. From the results, Fuzzy logic control was shown to achieve an adequate DC capacitor energy storage optimization, the sinusoidal type of the current and the change of the power factor. A low Total Harmonic Distortion (THD) that met the suggestions of IEEE- 519 standard on symphonious levels was achieved with the proposed method
    corecore