35 research outputs found

    Characterization of a Human Powered Nebulizer Compressor for Resource Poor Settings

    Get PDF
    Background Respiratory disease accounts for three of the ten leading causes of death worldwide. Many of these diseases can be treated and diagnosed using a nebulizer. Nebulizers can also be used to safely and efficiently deliver vaccines. Unfortunately, commercially available nebulizers are not designed for use in regions of the world where lung disease is most prevalent: they are electricity-dependent, cost-prohibitive, and not built to be reliable in harsh operating conditions or under frequent use. To overcome these limitations, the Human Powered Nebulizer compressor (HPN) was developed. The HPN does not require electricity; instead airflow is generated manually through a hand-crank or bicycle-style pedal system. A health care worker or other trained individual operates the device while the patient receives treatment. This study demonstrates functional specifications of the HPN in comparison with a standard commercially available electric jet nebulizer compressor, the DeVilbiss Pulmo-Aide 5650D (Pulmo-Aide). Methods Pressure and flow characteristics were measured with a rotameter and pressure transducer, respectively. Volume nebulized by each compressor was determined by mass, and particle size distribution was determined via laser diffraction. The Hudson RCI Micro Mist nebulizer mouthpiece was used with both compressors. Results The pressure and flow generated by the HPN and Pulmo-Aide were: 15.17 psi and 10.5 L/min; and 14.65 psi and 11.2 L/min, respectively. The volume of liquid delivered by each was equivalent, 1.097 ± 0.107 mL (mean ± s.e.m., n = 13) for the HPN and 1.092 ± 0.116 mL for the Pulmo-Aide. The average particle size was also equivalent, 5.38 ± 0.040 micrometers (mean ± s.e.m., n = 7) and 5.40 ± 0.025 micrometers, respectively. Conclusions Based on these characteristics, the HPN’s performance is equivalent to a popular commercially available electric nebulizer compressor. The findings presented in this paper, combined with the results of two published clinical studies, suggest that the HPN could serve as an important diagnostic and therapeutic tool in the fight against global respiratory health challenges including: tuberculosis, chronic obstructive pulmonary disease, asthma, and lower respiratory infections

    Treatment of Asthma Exacerbations with the Human-Powered Nebuliser: A Randomised Parallel-Group Clinical Trial

    Get PDF
    Aims: The aim of this study was to compare a low-cost, human-powered nebuliser compressor with an electric nebuliser compressor for the treatment of mild to moderate asthma exacerbations in adults and children. Methods: This was a non-blinded, parallel-group, equivalence study, with 110 subjects between 6 and 65 years of age, conducted in the emergency department of a district hospital in Ilopango, El Salvador. Participants were assigned by random allocation to receive a 2.5-mg dose of salbutamol from the experimental human-powered nebuliser or the electric nebuliser control. All assigned participants completed treatment and were included in analysis. The study was not blinded as this was clinically unfeasible; however, data analysis was blinded. Results: The mean improvement in peak flow of the experimental and control groups was 37.5 (95% confidence interval (CI) 26.7–48.2) l/min and 38.7 (95% CI, 26.1–51.3) l/min, respectively, with a mean difference of 1.3 (95% CI, −15.1 to 17.7) l/min. The mean improvement in percent-expected peak flow for the experimental and control groups was 12.3% (95% CI, 9.1–15.5%) and 13.8% (95% CI, 9.8–17.9%), respectively, with a mean difference of 1.5% (95% CI, −3.6 to 6.6%). Conclusions: The human-powered nebuliser compressor is equivalent to a standard nebuliser compressor for the treatment of mild-to-moderate asthma. (Funded by the Opus Dean’s Fund, Marquette University College of Engineering; ClinicalTrials.gov NCT01795742.

    An Ethical Façade? Medical Students' Miscomprehensions of Substituted Judgment

    Get PDF
    Background: We studied how well first-year medical students understand and apply the concept of substituted judgment, following a course on clinical ethics. Method: Students submitted essays on one of three ethically controversial scenarios presented in class. One scenario involved a patient who had lost decisional capacity. Through an iterative process of textual analysis, the essays were studied and coded for patterns in the ways students misunderstood or misapplied the principle of substituted judgment. Results: Students correctly articulated course principles regarding patient autonomy, substituted judgment, and nonimposition of physician values. However, students showed misunderstanding by giving doctors the responsibility of balancing the interests of the patient against the interests of the family, by stating doctors and surrogates should be guided primarily by a best-interest standard, and by suggesting that patient autonomy becomes the guiding principle only when patients can no longer express their wishes. Conclusion: Students did not appear to internalize or correctly apply the substituted judgment standard, even though they could describe it accurately. This suggests the substituted judgment standard may run counter to students ’ moral intuitions

    General Didactics and Instructional Design: eyes like twins A transatlantic dialogue about similarities and differences, about the past and the future of two sciences of learning and teaching

    Get PDF

    On Moral Medicine: Theological Perspectives in Medical Ethics, 3rd Edition

    No full text
    In print for more than two decades, On Moral Medicine remains the definitive anthology for Christian theological reflection on medical ethics. This third edition updates and expands the earlier award-winning volumes, providing classrooms and individuals alike with one of the finest available resources for ethics-engaged modern medicine.https://epublications.marquette.edu/marq_fac-book/1058/thumbnail.jp
    corecore