1,245 research outputs found
An XMM-Newton view of the serendipitous sources in the PKS0312-770 field
We describe an XMM-Newton observation of the PKS0312-770 field, which facilitates the spectral analysis of serendipitous sources previously detected by CHANDRA. The combination of larger effective area and longer exposure duration allows a significant increase in detected photons, and a lower limit in source detection sensitivity. In particular the hard X-ray normal galaxy unveiled by Fiore et al (2000) is most likely explained as a moderately absorbed (N_H ~ 1e22 cm^-2) AGN. We detect 52 sources (45 previously unreported) at a limiting flux of ~2e-15 cgs in the 0.5-2keV band. The LogN-LogS curve is consistent with that derived from by XMM-Newton observations of the Lockman Hole field. The flux determinations allow to check for any inconsistency between the calibrations of the two observatories, which is discussed
In-orbit Vignetting Calibrations of XMM-Newton Telescopes
We describe measurements of the mirror vignetting in the XMM-Newton
Observatory made in-orbit, using observations of SNR G21.5-09 and SNR
3C58 with the EPIC imaging cameras. The instrument features that complicate
these measurements are briefly described. We show the spatial and energy
dependences of measured vignetting, outlining assumptions made in deriving the
eventual agreement between simulation and measurement. Alternate methods to
confirm these are described, including an assessment of source elongation with
off-axis angle, the surface brightness distribution of the diffuse X-ray
background, and the consistency of Coma cluster emission at different position
angles. A synthesis of these measurements leads to a change in the XMM
calibration data base, for the optical axis of two of the three telescopes, by
in excess of 1 arcminute. This has a small but measureable effect on the
assumed spectral responses of the cameras for on-axis targets.Comment: Accepted by Experimental Astronomy. 26 pages, 18 figure
Discovery of complex narrow X-ray absorption features from the low-mass X-ray binary GX13+1 with XMM-Newton
We report the detection of a complex of narrow X-ray absorption features from the low-mass X-ray binary GX13+1 during 3 XMM-Newton observations in 2000 March and April. The features are consistent with being due to resonant scattering of the K_alpha and K_beta lines of He- and H-like iron (Fe xxv and Fe xxvi) and H-like calcium (Ca xx) K_alpha. Only the Fe xxvi K_alpha line has been previously observed from GX13+1. Due to the closeness in energy the Fe xxv and Fe xxvi K_beta features may also be ascribed to Nixxvii and Nixxviii K_alpha, respectively. We also find evidence for the presence of a deep (tau~0.2) Fe xxv absorption edge at 8.83 keV. The equivalent widths of the lines do not show any obvious variation on a timescale of a few days suggesting that the absorbing material is a stable feature of the system and present during a range of orbital phases
Influence of a carbon over-coat on the X-ray reflectance of XEUS mirrors
We describe measurements of the X-ray reflectance in the range 2 to 10 keV of
samples representative of coated silicon wafers that are proposed for the
fabrication of the XEUS (X-ray Evolving Universe Spectrometer) mission. We
compare the reflectance of silicon samples coated with bare Pt, with that for
samples with an additional 10nm thick carbon over-coating. We demonstrate a
significant improvement in reflectance in the energy range ~1 to 4 keV, and at
a grazing incidence angle of 10 mrad (0.57 degrees). We consider the resulting
effective area that could be attained with an optimized design of the XEUS
telescope. Typically an improvement of 10 to 60 % in effective area, depending
on photon energy, can be achieved using the carbon overcoat.Comment: 7 pages, 5 separate figures Accepted Optics Communication
X-ray Spectroscopy of the Cluster of Galaxies Abell 1795 with XMM-Newton
The initial results from XMM-Newton observations of the rich cluster of
galaxies Abell 1795 are presented. The spatially-resolved X-ray spectra taken
by the European Photon Imaging Cameras (EPIC) show a temperature drop at a
radius of kpc from the cluster center, indicating that the ICM is
cooling. Both the EPIC and the Reflection Grating Spectrometers (RGS) spectra
extracted from the cluster center can be described by an isothermal model with
a temperature of keV. The volume emission measure of any cool
component ( keV) is less than a few % of the hot component at the cluster
center. A strong OVIII Lyman-alpha line was detected with the RGS from the
cluster core. The O abundance and its ratio to Fe at the cluster center is
0.2--0.5 and 0.5--1.5 times the solar value, respectively.Comment: Accepted: A&A Letters, 2001, 6 page
An XMM and Chandra view of massive clusters of galaxies to z=1
The X-ray properties of a sample of high redshift (z>0.6), massive clusters
observed with XMM-Newton and Chandra are described, including two exceptional
systems. One, at z=0.89, has an X-ray temperature of T=11.5 (+1.1, -0.9) keV
(the highest temperature of any cluster known at z>0.6), an estimated mass of
(1.4+/-0.2)x10^15 solar masses and appears relaxed. The other, at z=0.83, has
at least three sub-clumps, probably in the process of merging, and may also
show signs of faint filamentary structure at large radii,observed in X-rays. In
general there is a mix of X-ray morphologies, from those clusters which appear
relaxed and containing little substructure to some highly non-virialized and
probably merging systems. The X-ray gas metallicities and gas mass fractions of
the relaxed systems are similar to those of low redshift clusters of the same
temperature, suggesting that the gas was in place, and containing its metals,
by z=0.8. The evolution of the mass-temperature relation may be consistent with
no evolution or with the ``late formation'' assumption. The effect of point
source contamination in the ROSAT survey from which these clusters were
selected is estimated, and the implications for the ROSAT X-ray luminosity
function discussed.Comment: 9 pages, in Carnegie Observatories Astrophysics Series, Vol. 3:
Clusters of Galaxies: Probes of Cosmological Structure and Galaxy Evolution,
ed. J. S. Mulchaey, A. Dressler, and A. Oemler. See
http://www.ociw.edu/ociw/symposia/series/symposium3/proceedings.html for a
full-resolution versio
UV observations of the galaxy cluster Abell 1795 with the optical monitor on XMM-Newton
We present the results of an analysis of broad band UV observations of the
central regions of Abell 1795 observed with the optical monitor on XMM-Newton.
As have been found with other UV observations of the central regions of
clusters of galaxies, we find evidence for star formation. However, we also
find evidence for absorption in the cD galaxy on a more extended scale than has
been seen with optical imaging. We also report the first UV observation of part
of the filamentary structure seen in H, X-rays and very deep U band
imaging. The part of the filament we see is very blue with UV colours
consistent with a very early (O/B) stellar population. This is the first direct
evidence of a dominant population of early type stars at the centre of Abell
1795 and implies very recent star formation at the centre of this clusterComment: 6 pages, 3 figures accepted by A&A Letter
- …