1,245 research outputs found

    An XMM-Newton view of the serendipitous sources in the PKS0312-770 field

    Get PDF
    We describe an XMM-Newton observation of the PKS0312-770 field, which facilitates the spectral analysis of serendipitous sources previously detected by CHANDRA. The combination of larger effective area and longer exposure duration allows a significant increase in detected photons, and a lower limit in source detection sensitivity. In particular the hard X-ray normal galaxy unveiled by Fiore et al (2000) is most likely explained as a moderately absorbed (N_H ~ 1e22 cm^-2) AGN. We detect 52 sources (45 previously unreported) at a limiting flux of ~2e-15 cgs in the 0.5-2keV band. The LogN-LogS curve is consistent with that derived from by XMM-Newton observations of the Lockman Hole field. The flux determinations allow to check for any inconsistency between the calibrations of the two observatories, which is discussed

    In-orbit Vignetting Calibrations of XMM-Newton Telescopes

    Full text link
    We describe measurements of the mirror vignetting in the XMM-Newton Observatory made in-orbit, using observations of SNR G21.5-09 and SNR 3C58 with the EPIC imaging cameras. The instrument features that complicate these measurements are briefly described. We show the spatial and energy dependences of measured vignetting, outlining assumptions made in deriving the eventual agreement between simulation and measurement. Alternate methods to confirm these are described, including an assessment of source elongation with off-axis angle, the surface brightness distribution of the diffuse X-ray background, and the consistency of Coma cluster emission at different position angles. A synthesis of these measurements leads to a change in the XMM calibration data base, for the optical axis of two of the three telescopes, by in excess of 1 arcminute. This has a small but measureable effect on the assumed spectral responses of the cameras for on-axis targets.Comment: Accepted by Experimental Astronomy. 26 pages, 18 figure

    Discovery of complex narrow X-ray absorption features from the low-mass X-ray binary GX13+1 with XMM-Newton

    Get PDF
    We report the detection of a complex of narrow X-ray absorption features from the low-mass X-ray binary GX13+1 during 3 XMM-Newton observations in 2000 March and April. The features are consistent with being due to resonant scattering of the K_alpha and K_beta lines of He- and H-like iron (Fe xxv and Fe xxvi) and H-like calcium (Ca xx) K_alpha. Only the Fe xxvi K_alpha line has been previously observed from GX13+1. Due to the closeness in energy the Fe xxv and Fe xxvi K_beta features may also be ascribed to Nixxvii and Nixxviii K_alpha, respectively. We also find evidence for the presence of a deep (tau~0.2) Fe xxv absorption edge at 8.83 keV. The equivalent widths of the lines do not show any obvious variation on a timescale of a few days suggesting that the absorbing material is a stable feature of the system and present during a range of orbital phases

    Influence of a carbon over-coat on the X-ray reflectance of XEUS mirrors

    Full text link
    We describe measurements of the X-ray reflectance in the range 2 to 10 keV of samples representative of coated silicon wafers that are proposed for the fabrication of the XEUS (X-ray Evolving Universe Spectrometer) mission. We compare the reflectance of silicon samples coated with bare Pt, with that for samples with an additional 10nm thick carbon over-coating. We demonstrate a significant improvement in reflectance in the energy range ~1 to 4 keV, and at a grazing incidence angle of 10 mrad (0.57 degrees). We consider the resulting effective area that could be attained with an optimized design of the XEUS telescope. Typically an improvement of 10 to 60 % in effective area, depending on photon energy, can be achieved using the carbon overcoat.Comment: 7 pages, 5 separate figures Accepted Optics Communication

    X-ray Spectroscopy of the Cluster of Galaxies Abell 1795 with XMM-Newton

    Get PDF
    The initial results from XMM-Newton observations of the rich cluster of galaxies Abell 1795 are presented. The spatially-resolved X-ray spectra taken by the European Photon Imaging Cameras (EPIC) show a temperature drop at a radius of 200\sim 200 kpc from the cluster center, indicating that the ICM is cooling. Both the EPIC and the Reflection Grating Spectrometers (RGS) spectra extracted from the cluster center can be described by an isothermal model with a temperature of 4\sim 4 keV. The volume emission measure of any cool component (<1<1 keV) is less than a few % of the hot component at the cluster center. A strong OVIII Lyman-alpha line was detected with the RGS from the cluster core. The O abundance and its ratio to Fe at the cluster center is 0.2--0.5 and 0.5--1.5 times the solar value, respectively.Comment: Accepted: A&A Letters, 2001, 6 page

    An XMM and Chandra view of massive clusters of galaxies to z=1

    Full text link
    The X-ray properties of a sample of high redshift (z>0.6), massive clusters observed with XMM-Newton and Chandra are described, including two exceptional systems. One, at z=0.89, has an X-ray temperature of T=11.5 (+1.1, -0.9) keV (the highest temperature of any cluster known at z>0.6), an estimated mass of (1.4+/-0.2)x10^15 solar masses and appears relaxed. The other, at z=0.83, has at least three sub-clumps, probably in the process of merging, and may also show signs of faint filamentary structure at large radii,observed in X-rays. In general there is a mix of X-ray morphologies, from those clusters which appear relaxed and containing little substructure to some highly non-virialized and probably merging systems. The X-ray gas metallicities and gas mass fractions of the relaxed systems are similar to those of low redshift clusters of the same temperature, suggesting that the gas was in place, and containing its metals, by z=0.8. The evolution of the mass-temperature relation may be consistent with no evolution or with the ``late formation'' assumption. The effect of point source contamination in the ROSAT survey from which these clusters were selected is estimated, and the implications for the ROSAT X-ray luminosity function discussed.Comment: 9 pages, in Carnegie Observatories Astrophysics Series, Vol. 3: Clusters of Galaxies: Probes of Cosmological Structure and Galaxy Evolution, ed. J. S. Mulchaey, A. Dressler, and A. Oemler. See http://www.ociw.edu/ociw/symposia/series/symposium3/proceedings.html for a full-resolution versio

    UV observations of the galaxy cluster Abell 1795 with the optical monitor on XMM-Newton

    Full text link
    We present the results of an analysis of broad band UV observations of the central regions of Abell 1795 observed with the optical monitor on XMM-Newton. As have been found with other UV observations of the central regions of clusters of galaxies, we find evidence for star formation. However, we also find evidence for absorption in the cD galaxy on a more extended scale than has been seen with optical imaging. We also report the first UV observation of part of the filamentary structure seen in Hα\alpha, X-rays and very deep U band imaging. The part of the filament we see is very blue with UV colours consistent with a very early (O/B) stellar population. This is the first direct evidence of a dominant population of early type stars at the centre of Abell 1795 and implies very recent star formation at the centre of this clusterComment: 6 pages, 3 figures accepted by A&A Letter
    corecore