    Thermo-mechanical compatibility of CFRP versus steel reinforcement for concrete at high temperature

    Get PDF
    Optimization of the design of concrete structures has become a driver for the use of nonconventional reinforcing materials. One example of this is the emerging use of non-corrosive, highstrength, and lightweight carbon fibre reinforced polymer (CFRP) prestressing tendons. It is widely known that the bond between FRP reinforcing tendons and concrete deteriorates at elevated temperature due to a combination of factors. Lateral thermal expansion of FRP reinforcing tendons at elevated temperature has been shown to have consequences for the bond performance of these systems. This paper presents the results of an experimental study carried out to assess the occurrence of heat-induced longitudinal splitting cracks in concrete specimens reinforced with CFRP or steel prestressing tendons. A novel testing methodology, namely a Heat-Transfer Rate Inducing System (H-TRIS), is used to subject specimens to thermal loading which replicates that experienced by equivalent specimens in a standard fire resistance test. A comparison between CFRP and steel tendons is made, and the occurrence of longitudinal splitting cracks is evaluated in terms of the time to occurrence and thermal gradient within the concrete. Results are compared against an available analytical model

    Thermal incompatibility between CFRP tendons and concrete

    Get PDF

    Fretting Fatigue Performance of Unidirectional, Laminated Carbon Fibre Reinforced Polymer Straps at Elevated Service Temperature

    Get PDF
    The fretting fatigue performance of laminated, unidirectional (UD), pin-loaded, carbon fibre-reinforced polymer (CFRP) straps that can be used as bridge hanger cables was investigated at a sustained service temperature of 60 °C. The aim of this paper is to elucidate the influence of the slightly elevated service temperature on the tensile fatigue performance of CFRP straps. First, steady state thermal tests at ambient temperature and at 60 °C are presented, in order to establish the behaviour of the straps at these temperatures. These results indicated that the static tensile performance of the straps is not affected by the increase in temperature. Subsequently, nine upper stress levels (USLs) between 650 and 1400 MPa were chosen in order to establish the S–N curve at 60 °C (frequency 10 Hz; R = 0.1) and a comparison with an existing S–N curve at ambient temperature was made. In general, the straps fatigue limit was slightly decreased by temperature, up to 750 MPa USL, while, for the higher USLs, the straps performed slightly better as compared with the S–N curve at ambient temperature
    corecore