19 research outputs found

    Avaliação de métodos de baixo custo para medição de vazão em córregos

    Full text link

    Exercise training prior to myocardial infarction attenuates cardiac deterioration and cardiomyocyte dysfunction in rats

    Get PDF
    OBJECTIVES: The present study was performed to investigate 1) whether aerobic exercise training prior to myocardial infarction would prevent cardiac dysfunction and structural deterioration and 2) whether the potential cardiac benefits of aerobic exercise training would be associated with preserved morphological and contractile properties of cardiomyocytes in post-infarct remodeled myocardium. METHODS: Male Wistar rats underwent an aerobic exercise training protocol for eight weeks. The rats were then assigned to sham surgery (SHAM), sedentary lifestyle and myocardial infarction or exercise training and myocardial infarction groups and were evaluated 15 days after the surgery. Left ventricular tissue was analyzed histologically, and the contractile function of isolated myocytes was measured. Student's t-test was used to analyze infarct size and ventricular wall thickness, and the other parameters were analyzed by the Kruskal-Wallis test followed by Dunn's test or a one-way analysis of variance followed by Tukey's test (

    Impact of COVID-19 on cardiovascular testing in the United States versus the rest of the world

    Get PDF
    Objectives: This study sought to quantify and compare the decline in volumes of cardiovascular procedures between the United States and non-US institutions during the early phase of the coronavirus disease-2019 (COVID-19) pandemic. Background: The COVID-19 pandemic has disrupted the care of many non-COVID-19 illnesses. Reductions in diagnostic cardiovascular testing around the world have led to concerns over the implications of reduced testing for cardiovascular disease (CVD) morbidity and mortality. Methods: Data were submitted to the INCAPS-COVID (International Atomic Energy Agency Non-Invasive Cardiology Protocols Study of COVID-19), a multinational registry comprising 909 institutions in 108 countries (including 155 facilities in 40 U.S. states), assessing the impact of the COVID-19 pandemic on volumes of diagnostic cardiovascular procedures. Data were obtained for April 2020 and compared with volumes of baseline procedures from March 2019. We compared laboratory characteristics, practices, and procedure volumes between U.S. and non-U.S. facilities and between U.S. geographic regions and identified factors associated with volume reduction in the United States. Results: Reductions in the volumes of procedures in the United States were similar to those in non-U.S. facilities (68% vs. 63%, respectively; p = 0.237), although U.S. facilities reported greater reductions in invasive coronary angiography (69% vs. 53%, respectively; p < 0.001). Significantly more U.S. facilities reported increased use of telehealth and patient screening measures than non-U.S. facilities, such as temperature checks, symptom screenings, and COVID-19 testing. Reductions in volumes of procedures differed between U.S. regions, with larger declines observed in the Northeast (76%) and Midwest (74%) than in the South (62%) and West (44%). Prevalence of COVID-19, staff redeployments, outpatient centers, and urban centers were associated with greater reductions in volume in U.S. facilities in a multivariable analysis. Conclusions: We observed marked reductions in U.S. cardiovascular testing in the early phase of the pandemic and significant variability between U.S. regions. The association between reductions of volumes and COVID-19 prevalence in the United States highlighted the need for proactive efforts to maintain access to cardiovascular testing in areas most affected by outbreaks of COVID-19 infection

    Experimental validation of methodologies for continuous measurement of flow in the Ribeirão da Onça basin

    No full text
    Desde 2004, o grupo de estudos do Laboratório de Hidráulica Computacional (LHC) estuda as taxas de recargas hidráulicas do Aquifero Guarani, na Bacia do Ribeirão da Onça. Entretanto, não havia se estudado a quantificação do escoamento superficial. Para sanar esta deficiência, este trabalho visou analisar as metodologias de estimativa de vazão com qualidade para a Bacia do Ribeirão da Onça. Para a realização do trabalho, foi adquirido o equipamento Flo-Tote3, capaz de medir velocidade e nível d\'água. A princípio, o equipamento foi verificado e comparado em laboratório, medindo velocidades 3% inferiores que o molinete e estimando vazões de 0,5 a 7,2% de diferença que o vertedor triangular. No Ribeirão da Onça, foi escolhida e construída uma seção de controle de vazão e instalado o Flo-Tote. O equipamento mediu velocidades 5% inferiores que o molinete, com variações de 0,3 a 8,7%. Além disso, um vertedor circular foi instalado em 6 ocasiões, resultando em vazões de 3 a 15% inferiores as vazões estimadas pelo molinete, em virtude do vazamento que ocorreu entre o vertedor e a parede de concreto. A partir de dezembro de 2007, foram iniciadas medições de níveis d\'água com a construção do linígrafo e estimadas as vazões de modo contínuo com o auxílio de equações teóricas. Como a jusante da seção de controle de vazão existe um sistema de bombeamento, as equações para determinar a vazão sofrem interferencias. Entretanto, foi aplicado o método das isotáquias, que utiliza valores de velocidades e níveis d\'água para o cálculo da vazão e que não sofre interferências com o represamento e instalações de vertedores. Apesar de ocorrer problemas de falta de energia e de manutenção, o escoamento superficial foi quantificado com qualidade para futuros estudos da área afim.Since 2004, the group of studies of the Computational Hydraulic Laboratory (LHC) studied the rates of water recharge in the Guarani Aquifer recharges water in the Ribeirão da Onça basin. However, it had not studied the quantification of runoff. To remedy this deficiency, this study aimed to analyze the methodologies for estimation of flow quality for the Ribeirão da Onça basin. To carry out the work, it was acquired a Flo-Tote3, capable of measuring velocities and water levels. First, this equipment was checked and compared in the laboratory, measuring velocities 3% below, those obtained using flowmeters and 0.5 to 7.2% differences when compared with results using triangular weir. In Ribeirão da Onça, was chosen and built a section of control flow and installed the Flo-Tote. The equipment measured velocities 5% below the current meters, with variations from 0.3 to 8.7%. In addition, a circular weir was installed on 6 occasions, resulting in flow rates from 3 to 15% lower than those estimated by current meters because of the flow that occurred between the bridge and weir. Since December 2007, started the measurements of water levels and the estimated flow on a continuous basis with the aid of theoretical equations. As the downstream section of the control flow is a pumping system, the equations to determine the flow are interfered. However, it was applied the method of the lines of the same velocities, which uses values of velocities and water levels to calculate the flow without interference with the impoundment and installation of weirs. Despite the problems of lack of energy and maintenance, the runoff was quantified with quality for future studies of the area

    Avaliação de métodos de baixo custo para medição de vazão em córregos

    No full text
    Com o aumento das taxas de polui&#231;&#227;o e sobre-explota&#231;&#227;o, a disponibilidade de &#225;gua em muitas regi&#245;es do mundo tem diminu&#237;do. Nesse contexto, o gerenciamento quali-quantitativo dos recursos h&#237;dricos dispon&#237;veis torna-se de primordial import&#226;ncia. Assim, este trabalho objetiva avaliar a aplicabilidade de dois m&#233;todos de medi&#231;&#227;o de vaz&#227;o de baixo custo, por&#233;m com precis&#227;o adequada: m&#233;todo eletromagn&#233;tico e m&#233;todo do bueiro. Os m&#233;todos foram aplicados em campo (bacia do Ribeir&#227;o da On&#231;a), visando &#224; identifica&#231;&#227;o de suas vantagens e desvantagens, tendo como refer&#234;ncia o m&#233;todo tradicional de medi&#231;&#227;o de vaz&#227;o (molinete). Comparando as vaz&#245;es com medi&#231;&#245;es convencionais, o medidor eletromagn&#233;tico apresentou um desvio m&#233;dio de -5%, por&#233;m possibilitou a medi&#231;&#227;o de velocidades em condi&#231;&#245;es de turbul&#234;ncia, ocasionadas pelas paredes laterais do canal. O m&#233;todo do bueiro apresentou desvios de vaz&#227;o de 2,1%, por&#233;m apresentou limita&#231;&#245;es em situa&#231;&#245;es de cheia. Os dois m&#233;todos de baixo custo apresentaram bons resultados referente &#224; determina&#231;&#227;o da vaz&#227;o, por&#233;m &#233; fundamental o conhecimento de suas limita&#231;&#245;es operacionais

    The estimation of the uncertainty associated with rating curves of the river Ivinhema in the state of Paraná/Brazil

    No full text
    The estimation of the uncertainty associated with stage-discharge relations is a challenge to the hydrologists. Bayesian inference with likelihood estimator is a promissory approach. The choice of the likelihood function has an important impact on the capability of the model to represent the residues. This paper aims evaluate two likelihood functions with DREAM algorithm to estimate specific non-unique stage-discharge rating curves: normal likelihood function and Laplace likelihood function. The result of BaRatin is also discussed. The MCMC of the DREAM and the BaRatin algorithm have been compared and its results seem consistent for the studied case. The Laplace likelihood function presented as good results as normal likelihood function for the residues. Other gauging stations should be evaluated to attend more general conclusions

    The estimation of the uncertainty associated with rating curves of the river Ivinhema in the state of Paraná/Brazil

    No full text
    The estimation of the uncertainty associated with stage-discharge relations is a challenge to the hydrologists. Bayesian inference with likelihood estimator is a promissory approach. The choice of the likelihood function has an important impact on the capability of the model to represent the residues. This paper aims evaluate two likelihood functions with DREAM algorithm to estimate specific non-unique stage-discharge rating curves: normal likelihood function and Laplace likelihood function. The result of BaRatin is also discussed. The MCMC of the DREAM and the BaRatin algorithm have been compared and its results seem consistent for the studied case. The Laplace likelihood function presented as good results as normal likelihood function for the residues. Other gauging stations should be evaluated to attend more general conclusions

    Redes e sua Implementação em Laboratórios de Informática

    No full text
    O LIpE - Laboratório de Informática para Educação – tem a proposta de utilizar a informática como ferramenta principal para o processo de ensino-aprendizado, fomentando continuamente projetos relacionados que podem ser devidamente utilizados para o processo educativo de usuários dos mais diversos perfis, priorizando sempre o usuário mínimo, ou seja, aquele que tem o menor conhecimento na área, devido à aguda necessidade do indivíduo estar atualizado e informatizado atualmente. Pode-se citar aulas de alfabetização digital a crianças, jovens e adultos, aulas de lógica e programação de jogos utilizando a ferramenta scratch e minicurso de arduíno, sempre tendo como apoio o uso de softwares livres e a metodologia participativa, conceito amplamente empregado pela equipe de redes com a participação dos envolvidos. A implementação de servidores de arquivos e web atua como  meio  primordial pelo qual as atividades do LIpE são realizadas, portanto necessitam de uma rede interconectada que ofereça serviços de internet, HD compartilhado, gerenciamento de usuários, criação do website do LIpE, além da manutenção desses serviços. Vale ressaltar que tal implementação não pode ser comparada apenas ao mero serviço técnico tradicional, pois é parte essencial na prática da extensão a qual o LIpE objetiva fundamentalmente. Além disso, através da metodologia participativa, as mudanças no funcionamento são orientadas pelos próprios usuários da rede em questão e passadas à nossa equipe, fazendo assim com que a técnica não se sobreponha às necessidades do usuário como ocorre em diversos meios e sim, que ocorra o oposto. O LIpE prima pela difusão do conhecimento, elaborando manuais e oficinas de rede com conteúdo prático e linguagem clara e intuitiva para que o conteúdo técnico seja apropriado por todos, inicialmente qualificando os integrantes das outras equipes de trabalho, quanto a outros graduandos, tendo como objetivo expandir futuras oficinas voltadas à comunidade externa, ou até mesmo ministrada por pessoa externas à UFRJ, criando os professores multiplicadores. Podemos citar como ferramenta para tal o mediawiki, desenvolvido de forma conjunta pelos integrantes do laboratório, que reúne em forma de manuais minuciosos, grande parte do conhecimento acumulado referente às diferentes equipes do LIpE. É importante ressaltar que o processo da construção do conhecimento compartilhado possibilita a formação da graduação pela extensão, permitindo assim, a expansão do conhecimento e, consequentemente, um maior aprendizado para todos os envolvidos
    corecore