179 research outputs found

    Coronary artery spasm and non-Q-wave myocardial infarction following intravenous ephedrine in two healthy women under spinal anaesthesia

    Get PDF
    Vasovagal episodes occur frequently in young healthy patients undergoing venous cannulation and loco-regional anaesthesia. We report two cases of severe coronary vasospasm and non-Qwave infarction in healthy young women after administration of ephedrine for vasovagal symptoms at the onset of spinal anaesthesia. In the light of unopposed vagal predominance predisposing patients to coronary vasospasm, even in young healthy patients, atrophine and not ephedrine should be the first line treatment for bradycardia with or without hypotension under spinal anaesthesi

    Stimulation induced variability of pulse plethysmography does not discriminate responsiveness to intubation

    Get PDF
    Background. Hypnotic depth but not haemodynamic response to painful stimulation can be measured with various EEG-based anaesthesia monitors. We evaluated the variation of pulse plethysmography amplitude induced by an electrical tetanic stimulus (PPG variation) as a potential measure for analgesia and predictor of haemodynamic responsiveness during general anaesthesia. Methods. Ninety-five patients, ASA I or II, were randomly assigned to five groups [Group 1: bispectral index (BIS) (range) 40-50, effect site remifentanil concentration 1 ng ml−1;Group 2: BIS 40-50, remifentanil 2 ng ml−1; Group 3: BIS 40-50, remifentanil 4 ng ml−1; Group 4: BIS 25-35, remifentanil 2 ng ml−1; Group 5: BIS 55-65, remifentanil 2 ng ml−1]. A 60 mA tetanic stimulus was applied for 5 s on the ulnar nerve. From the digitized pulse oximeter wave recorded on a laptop computer, linear and non-linear parameters of PPG variation during the 60 s period after stimulation were computed. The haemodynamic response to subsequent orotracheal intubation was recorded. The PPG variation was compared between groups and between responders and non-responders to intubation (anova). Variables independently predicting the response were determined by logistic regression. Results. The probability of a response to tracheal intubation was 0.77, 0.47, 0.05, 0.18 and 0.52 in Groups 1-5, respectively (P<0.03). The PPG variability was significantly higher in responders than in non-responders but it did not improve the prediction of the response to tracheal intubation based on BIS level and effect site remifentanil concentration. Conclusion. Tetanic stimulation induced PPG variation does not reflect the analgesic state in a wide clinical range of surgical anaesthesi

    Heart rate variability does not discriminate between different levels of haemodynamic responsiveness during surgical anaesthesia†

    Get PDF
    Background Hypnotic depth but not haemodynamic responsiveness is measured with EEG-based monitors. In this study we compared heart rate variability (HRV) in unstimulated patients and stimulation-induced HRV at different levels of anaesthesia. Methods A total of 95 ASA I or II patients were randomly assigned to five groups (Group 1: BIS 45(5), remifentanil 1 ng ml−1; Group 2: BIS 45(5), remifentanil 2 ng ml−1; Group 3: BIS 45(5), remifentanil 4 ng ml−1; Group 4: BIS 30(5), remifentanil 2 ng ml−1; Group 5: BIS 60(5), remifentanil 2 ng ml−1). A time- and frequency-domain analysis of the RR interval (RRI) from the electrocardiogram was performed. HRV before induction, before and after a 5 s tetanic stimulus of the ulnar nerve, and before and after tracheal intubation was compared between groups, between stimuli, and between responders to intubation [systolic arterial pressure (SAP) increase >20 mm Hg, a maximal heart rate (HR) after intubation >90 min−1 or both] and non-responders (anova). Results Induction of anaesthesia significantly lowered HR and HRV. Mean RRI before stimulation was higher in G3 than in G1, G2, and G4 (P < 0.001), whereas the other HRV parameters were similar. Intubation induced a greater HRV response than tetanic stimulation. The mean RRI after intubation was lower in G3 compared with the other groups and the sd of the RRI after tetanic stimulation was lower in G3 compared with G5. Otherwise, unstimulated HRV and stimulation-induced HRV were similar in responders and non-responders. Conclusion HRV parameters discriminate between awake and general anaesthesia, are different after tracheal intubation and a 5 s ulnar nerve stimulation, but do not discriminate between different levels of haemodynamic responsiveness during surgical anaesthesi

    Different Learning Curves for Axillary Brachial Plexus Block: Ultrasound Guidance versus Nerve Stimulation

    Get PDF
    Little is known about the learning of the skills needed to perform ultrasound- or nerve stimulator-guided peripheral nerve blocks. The aim of this study was to compare the learning curves of residents trained in ultrasound guidance versus residents trained in nerve stimulation for axillary brachial plexus block. Ten residents with no previous experience with using ultrasound received ultrasound training and another ten residents with no previous experience with using nerve stimulation received nerve stimulation training. The novices' learning curves were generated by retrospective data analysis out of our electronic anaesthesia database. Individual success rates were pooled, and the institutional learning curve was calculated using a bootstrapping technique in combination with a Monte Carlo simulation procedure. The skills required to perform successful ultrasound-guided axillary brachial plexus block can be learnt faster and lead to a higher final success rate compared to nerve stimulator-guided axillary brachial plexus block

    Prediction of the haemodynamic response to tracheal intubation: comparison of laser-Doppler skin vasomotor reflex and pulse wave reflex

    Get PDF
    Background. The laser-Doppler skin vasomotor reflex (SVmR) caused by tetanic stimulation of the ulnar nerve may be a test that can predict the haemodynamic response to tracheal intubation. A decrease in pulse wave amplitude (pulse wave reflex, PWR) may be an alternative index of this response. We compared the abilities of PWR and SVmR to predict the haemodynamic response to tracheal intubation and studied how alfentanil, muscle relaxation, stimulation site and stimulation pattern affected the two reflexes. Methods. Anaesthesia was induced and maintained with 2% sevoflurane and 50% nitrous oxide in two groups of 10 ASA status I patients. Tetanic stimuli were applied to the flexor muscles of the forearm and the ulnar nerve before and after administration of vecuronium. The change in skin blood flow (laser-Doppler) and pulse wave amplitude (pulse oximetry) after a 5 and 10 s stimulation was measured on the opposite hand. If skin blood flow (laser-Doppler) decreased by more than 10%, a computer-controlled infusion of alfentanil was started and the target plasma concentration was increased in steps until this response was suppressed (<10%). The trachea was intubated and arterial pressure and heart rate responses were recorded. Plasma alfentanil concentration was measured. Results. When PWR and SVmR were suppressed, the haemodynamic response to tracheal intubation was reduced in 100 and 53% of patients respectively. PWR and SVmR responses decreased with increasing plasma alfentanil concentration. The SVmR response to muscle stimulation was reduced by muscle relaxants. The pulse wave response to both muscle and neural stimulation was reduced by relaxants. The responses to 5 and 10 s stimulations were similar. Conclusion. An absent SVmR does not predict a blunted arterial pressure or heart rate response to tracheal intubation. The PWR may be a better predicto

    An international proficiency test to detect, identify and quantify ricin in complex matrices

    Get PDF
    While natural intoxications with seeds of Ricinus communis have long been known, the toxic protein ricin contained in the seeds is of major concern due to its history of criminal, terrorist and military use. In order to harmonize detection capabilities in expert laboratories an international proficiency test was organized that aimed at identifying good analytical practices (qualitative measurements) and determining a consensus concentration on a highly pure ricin reference material (quantitative measurements). Sample materials included highly pure ricin as well as the related R. communis agglutinin spiked into buffer, milk and meat extract; additionally, an organic fertilizer naturally contaminated with R. communis shred was investigated in the proficiency test. The qualitative results showed that either a suitable combination of immunological, MS-based and functional approaches or sophisticated MS-based approaches alone successfully allowed to detect and identify ricin in all samples. In terms of quantification, it was possible to determine a consensus concentration for the highly pure ricin reference material. The results provide a basis for further steps in quality assurance and improve biopreparedness in expert laboratories worldwide.JRC.D.2-Standards for Innovation and sustainable Developmen

    Pharmacokinetic parameter sets of alfentanil revisited: optimal parameters for use in target controlled infusion and anaesthesia display systems

    Get PDF
    Background In open TCI and anaesthesia display systems, the choice of pharmacokinetic (PK) parameter sets of opioids is clinically relevant. Accuracy and bias of the PK models may be affected by administration mode and the co-administered hypnotic drug. We retrospectively evaluated the performance of eight PK parameter sets for alfentanil in two data sets (infusion and bolus application). Methods With the dosing history from two studies in orthopaedic patients anaesthetized with propofol or inhalation anaesthetics the alfentanil plasma concentration over time was calculated with eight PK parameter sets. Median absolute performance error (MDAPE), log accuracy, median performance error (MDPE), log bias, Wobble, and Divergence were computed. Mann-Whitney rank test with Bonferroni correction was used for comparison between bolus and infusion data, repeated measures analysis of variance on ranks was used for comparison among parameter sets. Results The parameters by Scott (original and weight adjusted) and Fragen had a MDAPE ≀30% and a median log accuracy <0.15 independent of the administration mode, while MDPE was within ±20% and log bias nearly within ±0.1, respectively. The sets by Maitre and Lemmens were within these limits only in the bolus data. All other parameter sets were outside these limits. Conclusions In healthy orthopaedic patients, the PK parameters by Scott and by Maitre were equally valid when alfentanil was given as repeated boluses. When given as infusion, the Maitre parameters were less accurate and subject to a significant bias. We cannot exclude that the difference between bolus and infusion is partially because of the different hypnotics use

    Inflammatory and metabolic responses to high-fat meals with and without dairy products in men.

    Get PDF
    Postprandial inflammation is an important factor for human health since chronic low-grade inflammation is associated with chronic diseases. Dairy products have a weak but significant anti-inflammatory effect on postprandial inflammation. The objective of the present study was to compare the effect of a high-fat dairy meal (HFD meal), a high-fat non-dairy meal supplemented with milk (HFM meal) and a high-fat non-dairy control meal (HFC meal) on postprandial inflammatory and metabolic responses in healthy men. A cross-over study was conducted in nineteen male subjects. Blood samples were collected before and 1, 2, 4 and 6 h after consumption of the test meals. Plasma concentrations of insulin, glucose, total cholesterol, LDL-cholesterol, HDL-cholesterol, TAG and C-reactive protein (CRP) were measured at each time point. IL-6, TNF-α and endotoxin concentrations were assessed at baseline and endpoint (6 h). Time-dependent curves of these metabolic parameters were plotted, and the net incremental AUC were found to be significantly higher for TAG and lower for CRP after consumption of the HFM meal compared with the HFD meal; however, the HFM and HFD meals were not different from the HFC meal. Alterations in IL-6, TNF-α and endotoxin concentrations were not significantly different between the test meals. The results suggest that full-fat milk and dairy products (cheese and butter) have no significant impact on the inflammatory response to a high-fat meal

    Utility of the SmartPilotÂź View advisory screen to improve anaesthetic drug titration and postoperative outcomes in clinical practice: a two-centre prospective observational trial.

    Get PDF
    BACKGROUND The advisory system SmartPilotÂź View (DrĂ€gerwerk AG, LĂŒbeck, Germany) provides real-time, demographically adjusted pharmacodynamic information throughout anaesthesia, including time course of effect-site concentrations of administered drugs and a measure of potency of the combined drug effect termed the "'Noxious Stimulation Response Index' (NSRI). This dual-centre, prospective, observational study assesses whether the availability of SmartPilotÂź View alters the behaviour of anaesthetic drug titration of anaesthetists and improves the Anaesthesia Quality Score (AQS; percentage of time spent with MAP 60-80 mm Hg and Bispectral Index [BIS] 40-60 [blinded]). METHODS We recruited 493 patients scheduled for elective surgery in two university centres. A control group (CONTROL; n=170) was enrolled to observe drug titration in current practice. Thereafter, an intervention group was enrolled, for which SmartPilotÂź View was made available to optimise drug titration (SPV; n=188). The AQS, haemodynamic and hypnotic effects, recovery times, pain scores, and other parameters were compared between groups. RESULTS There were 358 patients eligible for analysis. Anaesthesia quality score was similar between CONTROL and SPV (median AQS [Q1-Q3]) 25.3% [7.4-41.5%] and 22.2% [8.0-44.4%], respectively; P=0.898). Compared with CONTROL, SPV patients had less severe hypotension and hypertension, less BIS <40, faster tracheal extubation, and lower early postoperative pain scores. CONCLUSIONS Adding SmartPilotÂź View information did not affect average drug titration behaviour. However, small improvements in control of MAP and BIS and early recovery suggest improved titration for some patients without increasing the risk of overdosing or underdosing. CLINICAL TRIAL REGISTRATION NCT01467167
    • 

    corecore