31 research outputs found

    Results of a Prospective Trial to Compare 68Ga-DOTA-TATE with SiPM-Based PET/CT vs. Conventional PET/CT in Patients with Neuroendocrine Tumors

    No full text
    We prospectively enrolled patients with neuroendocrine tumors (NETs). They underwent a single 68Ga-DOTA-TATE injection followed by dual imaging and were randomly scanned using first either the conventional or the silicon photomultiplier (SiPM) positron emission tomography/computed tomography (PET/CT), followed by imaging using the other system. A total of 94 patients, 44 men and 50 women, between 35 and 91 years old (mean ± SD: 63 ± 11.2), were enrolled. Fifty-two out of ninety-four participants underwent SiPM PET/CT first and a total of 162 lesions were detected using both scanners. Forty-two out of ninety-four participants underwent conventional PET/CT first and a total of 108 lesions were detected using both scanners. Regardless of whether SiPM-based PET/CT was used first or second, maximum standardized uptake value (SUVmax) of lesions measured on SiPM was on average 20% higher when comparing two scanners with all enrolled patients, and the difference was statistically significant. SiPM-based PET/CT detected 19 more lesions in 13 patients compared with conventional PET/CT. No lesions were only identified by conventional PET/CT. In conclusion, we observed higher SUVmax for lesions measured from SiPM PET/CT compared with conventional PET/CT regardless of the order of the scans. SiPM PET/CT allowed for identification of more lesions than conventional PET/CT. While delayed imaging can lead to higher SUVmax in cancer lesions, in the series of lesions identified when SiPM PET/CT was used first, this was not the case; therefore, the data suggest superior performance of the SiPM PET/CT scanner in visualizing and quantifying lesions

    Initial experience with a SiPM-based PET/CT scanner: influence of acquisition time on image quality

    No full text
    Abstract Background A newly introduced PET/CT scanner (Discovery Meaningful Insights—DMI, GE Healthcare) includes the silicon photomultiplier (SiPM) with time-of-flight (TOF) technology first used in the GE SIGNA PET/MRI. In this study, we investigated the impact of various acquisition times on image quality using this SiPM-based PET/CT. Methods We reviewed data from 58 participants with cancer who were scanned using the DMI PET/CT scanner. The administered dosages ranged 295.3–429.9 MBq (mean ± SD 356.3 ± 37.4) and imaging started at 71–142 min (mean ± SD 101.41 ± 17.52) after administration of the radiopharmaceutical. The patients’ BMI ranged 19.79–46.16 (mean ± SD 26.55 ± 5.53). We retrospectively reconstructed the raw TOF data at 30, 60, 90, and 120 s/bed and at the standard image acquisition time per clinical protocol (180 or 210 s/bed depending on BMI). Each reconstruction was reviewed blindly by two nuclear medicine physicians and scored 1–5 (1—poor, 5—excellent quality). The liver signal-to-noise ratio (SNR) was used as a quantitative measure of image quality. Results The average scores ± SD of the readers were 2.61 ± 0.83, 3.70 ± 0.92, 4.36 ± 0.82, 4.82 ± 0.39, and 4.91 ± 0.91 for the 30, 60, 90, and 120 s/bed and at standard acquisition time, respectively. Inter-reader agreement on image quality assessment was good, with a weighted kappa of 0.80 (95% CI 0.72–0.81). In the evaluation of the effects of time per bed acquisition on semi-quantitative measurements, we found that the only time point significantly different from the standard time were 30 and 60 s (both with P  25, images can be acquired as fast as 90 s/bed using the SiPM PET/CT and still result in very good image quality (average score > 4)

    Conductometric Sensing with Individual InAs Nanowires

    No full text
    In this work, we isolate individual wurtzite InAs nanowires and fabricate electrical contacts at both ends, exploiting the single nanostructures as building blocks to realize two different architectures of conductometric sensors: (a) the nanowire is drop-casted onto—supported by—a SiO2/Si substrate, and (b) the nanowire is suspended at approximately 250 nm from the substrate. We test the source-drain current upon changes in the concentration of humidity, ethanol, and NO2, using synthetic air as a gas carrier, moving a step forward towards mimicking operational environmental conditions. The supported architecture shows higher response in the mid humidity range (50% relative humidity), with shorter response and recovery times and lower detection limit with respect to the suspended nanowire. These experimental pieces of evidence indicate a minor role of the InAs/SiO2 contact area; hence, there is no need for suspended nanostructures to improve the sensing performance. Moreover, the sensing capability of single InAs nanowires for detection of NO2 and ethanol in the ambient atmosphere is reported and discussed

    18F-florbetaben whole-body PET/MRI for evaluation of systemic amyloid deposition

    No full text
    Abstract Background Florbetaben, a 18F-labeled stilbene derivative (Neuraceq®, formerly known as BAY-949172), is a diagnostic radiopharmaceutical developed to visualize β-amyloid plaques in the brain. Here, we report a pilot study evaluating patients with suspected cardiac amyloidosis for systemic extent of disease. Methods We prospectively enrolled nine patients, 61–86 year old (mean ± SD 69.4 ± 8.6), referred from the cardiac amyloid clinic. First, dynamic imaging of the heart was acquired immediately after injection of 222–318.2 MBq (mean ± SD 270.1 ± 33.3) of 18F-florbetaben using the GE SIGNA PET/MRI. This was followed by a whole-body PET/MRI scan 60–146.4 min (mean ± SD 98 ± 33.4) after injection. Cardiac MRI sequences included ECG-triggered cine SSFP, T2-weighted, and late gadolinium-enhanced imaging. Whole-body MRI sequences included MRAC and axial T1-weighted imaging. Results High early uptake and delayed high uptake in the left ventricle correlated with amyloid deposition in five patients, while low uptake on early and delayed cardiac imaging was noted in four patients. Cardiac function measurements were successfully obtained in all participants. Areas of increased abnormal 18F-florbetaben accumulation were noted on delayed whole-body imaging in the bone marrow (seven patients), stomach (diffuse in five patients and focal in one patient), brain (five patients), salivary glands (three patients), tongue (three patients), spleen (three patients), skeletal muscles (three patients), ocular muscles (two patients), thyroid (two patients), pleura (two patients), kidneys (two patients), and lungs (two patients). Conclusions Whole-body 18F-florbetaben PET/MRI is promising for localization of systemic amyloid deposition. This technique may provide important structural and functional information regarding the organs involved by disease, with potential to guide biopsy and evaluate response to treatment. Trial registration Clinicaltrials.gov registration: NCT03119558

    Laccase-Catalyzed 1,4-Dioxane-Mediated Synthesis of Belladine N-Oxides with Anti-Influenza A Virus Activity

    Get PDF
    Belladine N-oxides active against influenza A virus have been synthetized by a novel laccase-catalyzed 1,4-dioxane-mediated oxidation of aromatic and side-chain modified belladine derivatives. Electron paramagnetic resonance (EPR) analysis confirmed the role of 1,4-dioxane as a co-oxidant. The reaction was chemo-selective, showing a high functional-group compatibility. The novel belladine N-oxides were active against influenza A virus, involving the early stage of the virus replication life cycle

    D690 PET/CT vs DMI PET/CT: DMI showed an additional focal avid FDG uptake area (black arrow).

    No full text
    <p>46 years-old man with myocardial sarcoidosis who underwent PET/CT for initial staging. DMI images were acquired 39.1 minutes after standard acquisition and 109.2 minutes after <sup>18</sup>F-FDG injection. A) D690 Maximum-intensity-projection (MIP); B) DMI MIP; C) D690 coronal fused image D) DMI coronal fused image.</p
    corecore