    First application of a new portable, miniaturized system for extracorporeal membrane oxygenation

    Get PDF
    Extracorporeal assist systems for respiratory and circulatory failure are increasingly used in intensive care medicine. Important technical innovations over the past years have resulted in improved biocompatibility and, consequently, reduced complication rates. Extracorporeal membrane oxygenation (ECMO) technology experienced a surge of use during the influenza A (H1N1) pandemic, but transport of unstable patients with life-threatening ARDS is still hazardous. We describe the first successful application of a newly developed, compact and easily portable ECMO device in a patient with severe ARDS due to influenza A (H1N1). Support with the miniaturized ECMO resulted in immediate improvement of gas exchange and a highly protective ventilation. Inspiratory pressure was decreased from 40 to 29 cmH2O and tidal volume per kilogram of predicted bodyweight could be reduced from 6.5 to 3.3 mL. Small and efficient heart-lung assist systems will become a tool of growing importance in intensive care medicine, both for profound respiratory and cardiac failure in the future. The reduced weight and compact design of the device greatly facilitates transport and handling of unstable patients on ECMO

    Fatal Pseudomonas aeruginosa pneumonia in a previously healthy woman was most likely associated with a contaminated hot tub

    Get PDF
    Community-acquired pneumonia due to Pseudomonas aeruginosa in previously healthy individuals is a rare disease that is associated with high fatality. On 14 February 2010 a previously healthy 49-year-old woman presented to an emergency room with signs and symptoms of pneumonia, 2 days after returning from a spa holiday in a wellness hotel. Blood cultures and respiratory specimens grew P. aeruginosa. Despite adequate antimicrobial therapy, the patient died of septic multiorgan failure on day nine of hospitalization. On February 26, nine water samples were taken from the hotel facilities used by the patient: In the hot tub sample 37,000 colony-forming units of P. aeruginosa/100 ml were detected. Two of five individual colonies from the primary plate used for this hot tub water sample were found to be genetically closely related to the patients’ isolates. Results from PFGE, AFLP and MLST analysis allowed the two lung isolates gained at autopsy and the whirlpool bathtub isolates to be allocated into one cluster. The patient most likely acquired P. aeruginosa from the contaminated water in the hotel’s hot tub. The detection of P. aeruginosa in high numbers in a hot tub indicates massive biofilm formation in the bath circulation and severe deficiencies in hygienic maintenance. The increasing popularity of hot tubs in hotels and private homes demands increased awareness about potential health risks associated with deficient hygienic maintenance

    Impact of a major soil fumigant spill on the planktonic ecosystem of Shasta Lake California.

    No full text
    On July 14, 1991, approximately 70 000 L of the soil fumigant Vapam®, metam sodium, was spilled into the upper Sacramento River, California. Twelve hours before this spill reached Shasta Lake we sampled several sites in a subsequently impacted area and two control stations. Thereafter, samples were collected at approximately 5-d intervals for 26 d. We observed an almost immediate and subsequent 99.9% decrease in zooplankton biomass within 2.0 km of the river inflow. Lake-water chlorophyll concentrations crashed immediately to 20% of prespill values, but rebounded to approximately 750% prespill values after 9 d as a result of a spill-driven diatom bloom. Dissolved inorganic nitrogen and phosphorus concentrations increased severalfold immediately after the spill but returned to prespill concentrations as the algal bloom peaked. Effects of the spill were clearly related to distance from the river inflow with strong effects observed within 2.0 km, and weak or no effects observed at 8.0 km into the reservoir. A dilution experiment, using varying mixtures of contaminated and control station lake water, strongly confirmed the principal findings of the field study. Our field and experimental data showed far more severe effects of the spill than single species bioassays and lake pesticide concentrations predicted. </jats:p

    Technical Complications during Veno-Venous Extracorporeal Membrane Oxygenation and Their Relevance Predicting a System-Exchange – Retrospective Analysis of 265 Cases

    Get PDF
    Objectives Technical complications are a known hazard in veno-venous extracorporeal membrane oxygenation (vvECMO). Identifying these complications and predictive factors indicating a developing system-exchange was the goal of the study. Methods Retrospective study on prospectively collected data of technical complications including 265 adult patients (Regensburg ECMO Registry, 2009-2013) with acute respiratory failure treated with vvECMO. Alterations in blood flow resistance, gas transfer capability, hemolysis, coagulation and hemostasis parameters were evaluated in conjunction with a system-exchange in all patients with at least one exchange (n = 83). Results Values presented as median (interquartile range). Patient age was 50(36–60) years, the SOFA score 11(8–14.3) and the Murray lung injury Score 3.33(3.3–3.7). Cumulative ECMO support time 3411 days, 9(6–15) days per patient. Mechanical failure of the blood pump (n = 5), MO (n = 2) or cannula (n = 1) accounted for 10% of the exchanges. Acute clot formation within the pump head (visible clots, increase in plasma free hemoglobin (frHb), serum lactate dehydrogenase (LDH), n = 13) and MO (increase in pressure drop across the MO, n = 16) required an urgent system-exchange, of which nearly 50% could be foreseen by measuring the parameters mentioned below. Reasons for an elective system-exchange were worsening of gas transfer capability (n = 10) and device-related coagulation disorders (n = 32), either local fibrinolysis in the MO due to clot formation (increased D-dimers [DD]), decreased platelet count; n = 24), or device-induced hyperfibrinolysis (increased DD, decreased fibrinogen [FG], decreased platelet count, diffuse bleeding tendency; n = 8), which could be reversed after system-exchange. Four MOs were exchanged due to suspicion of infection. Conclusions The majority of ECMO system-exchanges could be predicted by regular inspection of the complete ECMO circuit, evaluation of gas exchange, pressure drop across the MO and laboratory parameters (DD, FG, platelets, LDH, frHb). These parameters should be monitored in the daily routine to reduce the risk of unexpected ECMO failure

    Results from a national survey on COVID-19-associated mucormycosis in Germany: 13 patients from six tertiary hospitals

    No full text
    Background Most COVID-19-associated mucormycosis (CAM) cases are reported from India and neighbouring countries. Anecdotally cases from Europe have been presented. Objective To estimate the disease burden and describe the clinical presentation of CAM in Germany. Methods We identified cases through German mycology networks and scientific societies, and collected anonymised clinical information via FungiScope (R). Results We identified 13 CAM cases from six tertiary referral hospitals diagnosed between March 2020 and June 2021. Twelve patients had severe or critical COVID-19, eleven were mechanically ventilated for a median of 8 days (range 1-27 days) before diagnosis of CAM. Eleven patients received systemic corticosteroids. Additional underlying medical conditions were reported for all but one patient, five were immunocompromised because of malignancy or organ transplantation, three were diabetic. Eleven patients developed pneumonia. Mortality was 53.8% with a median time from diagnosis of mucormycosis to death of 9 days (range 0-214 days) despite treatment with liposomal amphotericin B and/or isavuconazole in 10 of 13 cases. CAM prevalence amongst hospitalised COVID-19 patients overall (0.67% and 0.58% in two centres) and those admitted to the intensive care unit (ICU) (1.47%, 1.78% and 0.15% in three centres) was significantly higher compared to non-COVID-19 patients (P < .001 for respective comparisons). Conclusion COVID-19-associated mucormycosis is rare in Germany, mostly reported in patients with comorbidities and impaired immune system and severe COVID-19 treated in the ICU with high mortality compared to mainly rhino-orbito-cerebral CAM in patients with mild COVID-19 in India. Risk for CAM is higher in hospitalised COVID-19 patients than in other patients
    corecore