203 research outputs found

    The cryogenic system for the superconducting solenoid magnet of the CMS experiment

    Get PDF
    The design concept of the CMS experiment, foreseen for the Large Hadron Collider (LHC) project at CERN, is based on a superconducting solenoid magnet. The large coil will be made of a four layers winding generating the 4 T uniform magnetic induction required by the detector. The length of the solenoid is 13 m with an inner diameter of 5.9 m. The mass kept at liquid helium temperature totals 220 t and the electromagnetic stored energy is 2.7 GJ. The windings are indirectly cooled with a liquid helium flow driven by a thermosyphon effect. The external cryogenic system consists of a 1.5 kW at 4.5 K (entropy equivalent) cryoplant including an additional liquid nitrogen precooling unit and a 5000 litre liquid helium buffer. The whole magnet and cryogenic system will be tested at the surface by 2003 before final installation in the underground area of LHC

    About optimal location of sensors and actuators for the control of flexible structures

    Get PDF
    This work deals with the problem of efficient location of sensors and actuators encountered in the domain of active control of flexible structure. It appears that the optimal solution depends upon the type ofcontrol scheme that is used as well as the kinds of sensors and actuators that are implemented, and on the criterion that is considered. This paper recalls and discusses some approaches that are presented in the literature and presents some results that are obtained with a mock-up equipped with piezoelectric sensors and actuators

    Active stabilization studies at the sub-nanometer level for future linear colliders

    Get PDF
    The next collider which will be able to contribute significantly to the comprehension of matter is a high energy linear collider. The luminosity of this collider will have to be of 1035cm-2s-1, which imposes a vertical beam size of 0,7nm. The relative motion between the last two focusing magnets should not exceed a third of the beam size above 4Hz. Ground motion and acoustic noise can induce vibrations that have to be compensated with active stabilisation. In this paper, we describe the three aspects needed for such a development. We have assessed sensors capable of measuring sub-nanometre displacements, performed numerical calculations using finite element models to get the dynamic response of the structure, and developed a feedback loop for the active stabilisation. Combining the expertise into a mecatronics project made it possible to obtain a displacement RMS at 5Hz of 0.13nm at the free end of our prototype

    Vibration stabilization for a cantilever magnet prototype at the subnanometer scale

    Get PDF
    In the future linear colliders, the size of the beams is in the nanometer range, which requires stabilization of the final magnets before the interaction point. In order to guarantee the desired luminosity, an absolute displacement lower than 1/3 of the beam size, above a few hertz, has to be obtained. This paper describes an adapted instrumentation, the developed feedback loops dedicated to the active compensation and an adapted modelling able to simulate the behaviour of the structure. The obtained results at the subnanometer scale at the free end of a cantilever magnet prototype with a combination of the developed active compensation method and a commercial active isolation system are described

    Active stabilization of a mechanical structure

    Get PDF
    This article [1] refers to a particular stage of our attempt to reach the stabilization of the linear collider final focus quadrupole. All along this final focus, an absolute displacement has to be lower than the third of nanometre above a few hertz. The presented intermediary step consists in doing active vibrations control of an elemen-tary mechanical structure in cantilever mode which is similar to the final focus. We consider mainly the active compensation and the latest results on a large prototype. Other aspects are also treated such as modelling, active isolation and instrumentation dedicated to the ground motion

    Study of coupled heat and water transfer in proton exchange membrane fuel cells by the way of internal measurements

    Get PDF
    Abstract. Measurements of electrode temperatures within a proton exchange membrane fuel cell were performed using platinum wires. A temperature difference of 7°C between the electrodes and the bipolar plates was observed for a cell operating at a current density of 1.5 A.cm -2 . These measurements show a strong non-uniformity of the temperature profile through membrane electrode assembly (MEA) that future phenomenological models must take into account. In addition, the simultaneous measurements of heat and water flux through the MEA leads to the conclusion that produced water crosses the diffusion layer in vapor phase. A very simple heat transfer model is proposed

    Modelling of simple cases in view of active stabilisation for a future linear collider

    Get PDF
    Final focus magnet stabilisation is an important issue when working with nanometre size beams. The present study focuses on mechanical stabilisation. As a first step, the case of a 1m free-fixed aluminium beam placed on a table with active stabilisation has been studied. This work describes three aspects, namely, sensors and actuators to measure and compensate ground motion, mechanical simulations and a feedback loop. Measurements done with low frequency velocity sensors (down to 0.1Hz) in our Annecy lab during office hours show that the displacement RMS on the active table is 1nm at 4Hz compared to 10nm without active stabilisation. Simulations of the dynamic response of the beam have been compared to measurements done with accelerometers placed on the clamping and on the free end of the aluminium beam. The results are in good agreement. We are therefore able to predict by simulation the response of a structure subjected to an external excitation. A first sketch of a feedback loop to compensate specific vibrations has also been developed and allows the simultaneous elimination of several resonance peaks on a reduced-size mock-up. This algorithm will be applied to stabilise a larger mock-up, leading to more realistic experimental conditions. In future tests, the active table will globally stabilise in a range of frequencies from 0.5Hz to 50Hz whereas the feedback loop will compensate single strong resonances

    What Does a habitus of the Soul Do? : The Case of the habitus of Faith in Bonaventure, Peter John Olivi and John Duns Scotus

    Get PDF
    While a habitus can be described as a disposition towards a certain type of act, such a definition is not sufficient to encompass the diversity of uses the medieval thinkers made of this concept. It is the aim of this paper to examine the habitus of faith in the voluntarist Franciscan tradition in order to illustrate several of its functions and how these varied from author to author. Studying how the habitus of faith works for Bonaventure, Peter John Olivi and John Duns Scotus allows us to examine different takes on these functions and illustrate the variety of possible positions even within a tradition that emphasizes the freedom and agency of the moral subject above all. We will emphasize the capacity a habitus grants to pick out its proper objects, in the present case, the objects of faith; the capacity to elicit certain acts that without it would not have been possible or at least that would not have had the moral value the habitus grants them; the capacity to unite several powers in the accomplishment of a given act.Peer reviewe
    • …
    corecore