8 research outputs found
External cardiac defibrillation during wet-surface cooling in pigs
Objective: During surface cooling with ice-cold water, safety and effectiveness of transthoracic defibrillation was assessed. Methods: In a pig ventricular fibrillation cardiac arrest model, once (n = 6), defibrillation was done first in a dry and then in a wet condition using the ThermoSuit System (Life Recovery Systems, HD, LLC, Kinnelon, NJ), which circulates a thin layer of ice-cold water (≈4°C) over the skin surface. Another time (n = 6), defibrillation was done first in a wet and then in a dry condition. Success of defibrillation was defined as restoration of spontaneous circulation, and the current and voltage of the defibrillation signal was measured. Results: There was a tendency toward less number of shocks needed for achieving restoration of spontaneous circulation in the wet condition as compared with the number of shocks needed in the dry condition. The energy delivered in both dry and wet conditions was 144 ± 3 J. Discussion: Transthoracic defibrillation is safe and effective in a wet condition after cooling with ice-cold water. © 2007 Elsevier Inc. All rights reserved
Establishment and characterization of a primary and a metastatic melanoma cell line from Grey horses
Major results from the first plasma campaign of the Wendelstein 7-X stellarator
After completing the main construction phase of Wendelstein 7-X (W7-X) and successfully commissioning the device, first plasma operation started at the end of 2015. Integral commissioning of plasma start-up and operation using electron cyclotron resonance heating (ECRH) and an extensive set of plasma diagnostics have been completed, allowing initial physics studies during the first operational campaign. Both in helium and hydrogen, plasma breakdown was easily achieved. Gaining experience with plasma vessel conditioning, discharge lengths could be extended gradually. Eventually, discharges lasted up to 6 s, reaching an injected energy of 4 MJ, which is twice the limit originally agreed for the limiter configuration employed during the first operational campaign. At power levels of 4 MW central electron densities reached 3 1019 m-3, central electron temperatures reached values of 7 keV and ion temperatures reached just above 2 keV. Important physics studies during this first operational phase include a first assessment of power balance and energy confinement, ECRH power deposition experiments, 2nd harmonic O-mode ECRH using multi-pass absorption, and current drive experiments using electron cyclotron current drive. As in many plasma discharges the electron temperature exceeds the ion temperature significantly, these plasmas are governed by core electron root confinement showing a strong positive electric field in the plasma centre.Peer reviewe
Major results from the first plasma campaign of the Wendelstein 7-X stellarator
\u3cp\u3eAfter completing the main construction phase of Wendelstein 7-X (W7-X) and successfully commissioning the device, first plasma operation started at the end of 2015. Integral commissioning of plasma start-up and operation using electron cyclotron resonance heating (ECRH) and an extensive set of plasma diagnostics have been completed, allowing initial physics studies during the first operational campaign. Both in helium and hydrogen, plasma breakdown was easily achieved. Gaining experience with plasma vessel conditioning, discharge lengths could be extended gradually. Eventually, discharges lasted up to 6 s, reaching an injected energy of 4 MJ, which is twice the limit originally agreed for the limiter configuration employed during the first operational campaign. At power levels of 4 MW central electron densities reached 3 10\u3csup\u3e19\u3c/sup\u3e m\u3csup\u3e-3\u3c/sup\u3e, central electron temperatures reached values of 7 keV and ion temperatures reached just above 2 keV. Important physics studies during this first operational phase include a first assessment of power balance and energy confinement, ECRH power deposition experiments, 2nd harmonic O-mode ECRH using multi-pass absorption, and current drive experiments using electron cyclotron current drive. As in many plasma discharges the electron temperature exceeds the ion temperature significantly, these plasmas are governed by core electron root confinement showing a strong positive electric field in the plasma centre.\u3c/p\u3