8 research outputs found

    Charge identification of fragments with the emulsion spectrometer of the FOOT experiment

    No full text

    Development and characterization of a Δ E-TOF detector prototype for the FOOT experiment

    No full text
    This paper describes the development and characterization of a ΔE-TOF detector composed of a plastic scintillator bar coupled at both ends to silicon photomultipliers. This detector is a prototype of a larger version which will be used in the FOOT (FragmentatiOn Of Target) experiment to identify the fragments produced by ion beams accelerated onto a hydrogen-enriched target. The final ΔE-TOF detector will be composed of two layers of plastic scintillator bars with orthogonal orientation and will measure, for each crossing fragment, the energy deposited in the plastic scintillator (ΔE), the time of flight (TOF), and the coordinates of the interaction position in the scintillator. To meet the FOOT experimental requirements, the detector should have energy resolution of a few percents and time resolution of 70 ps, and it should allow to discriminate multiple fragments belonging to the same event. To evaluate the achievable performances, the detector prototype was irradiated with protons of kinetic energy in the 70–230 MeV range and interacting at several positions along the bar. The measured energy resolution σΔE∕ΔE was 6–14%, after subtracting the fluctuations of the deposited energy. A time resolution σ between 120 and 180 ps was obtained with respect to a trigger detector. A spatial resolution σ of 1.9 cm was obtained for protons interacting at the center of the bar

    The Drift Chamber detector of the FOOT experiment: Performance analysis and external calibration

    No full text
    The study that we present is part of the preparation work for the setup of the FOOT (FragmentatiOn Of Target) experiment whose main goal is the measurement of the double differential cross sections of fragments produced in nuclear interactions of particles with energies relevant for particle therapy. The present work is focused on the characterization of the gas-filled drift chamber detector composed of 36 sensitive cells, distributed over two perpendicular views. Each view consists of six consecutive and staggered layers with three cells per layer. We investigated the detector efficiency and we performed an external calibration of the space–time relations at the level of single cells. This information was then used to evaluate the drift chamber resolution. An external tracking system realized with microstrip silicon detectors was adopted to have a track measurement independent on the drift chamber. The characterization was performed with a proton beam at the energies of 228 and 80 MeV. The overall hit detection efficiency of the drift chamber has been found to be 0.929±0.008 , independent on the proton beam energy. The spatial resolution in the central part of the cell is about 150±10 μ m and 300±10 μ m and the corresponding detector angular resolution has been measured to be 1.62±0.16 mrad and 2.1±0.4 mrad for the higher and lower beam energies, respectively. In addition, the best value on the intrinsic drift chamber resolution has been evaluated to be in the range 60−100 μ m. In the framework of the FOOT experiment, the drift chamber will be adopted in the pre-target region, and will be exploited to measure the projectile direction and position, as well as for the identification of pre-target fragmentation events

    Characterization of 150 μm\mu m thick silicon microstrip prototype for the FOOT experiment

    No full text
    International audienceThe goals of the FOOT (FragmentatiOn Of Target) experiment are to measure the proton double differential fragmentation cross-section on H, C, O targets at beam energies of interest for hadrontherapy (50–250 MeV for protons and 50–400 MeV/u for carbon ions), and also at higher energy, up to 1 GeV/u for radioprotection in space. Given the short range of the fragments, an inverse kinematic approach has been chosen, requiring precise tracking capabilities for charged particles. One of the subsystems designed for the experiment will be the MSD (Microstrip Silicon Detector), consisting of three x-y measurement planes, each one made by two single sided silicon microstrip sensors. In this document, we will present a detailed description of the first MSD prototype assembly, developed by INFN Perugia group and the subsequent characterization of the detector performance. The prototype is a wide area(∼ 100 cm2^{2}) single sensor, 150 μm thick to reduce material budget and fragmentation probability along the beam path, with 50 μm strip pitch and 2 floating strip readout approach. The pitch adapter to connect strips with the readout channels of the ASIC has been implemented directly on the silicon surface. Beside the interest for the FOOT experiment, the results in terms of cluster signal, signal-to-noise ratio, dynamic range of the readout chips, as well as long-term stability studies in terms of noise, are relevant also for other experiments where the use of thin sensors is crucial

    Characterization of 150 μm thick silicon microstrip prototype for the FOOT experiment

    No full text
    International audienceThe goals of the FOOT (FragmentatiOn Of Target) experiment are to measure the proton double differential fragmentation cross-section on H, C, O targets at beam energies of interest for hadrontherapy (50–250 MeV for protons and 50–400 MeV/u for carbon ions), and also at higher energy, up to 1 GeV/u for radioprotection in space. Given the short range of the fragments, an inverse kinematic approach has been chosen, requiring precise tracking capabilities for charged particles. One of the subsystems designed for the experiment will be the MSD (Microstrip Silicon Detector), consisting of three x-y measurement planes, each one made by two single sided silicon microstrip sensors. In this document, we will present a detailed description of the first MSD prototype assembly, developed by INFN Perugia group and the subsequent characterization of the detector performance. The prototype is a wide area(∼ 100 cm2^{2}) single sensor, 150 μm thick to reduce material budget and fragmentation probability along the beam path, with 50 μm strip pitch and 2 floating strip readout approach. The pitch adapter to connect strips with the readout channels of the ASIC has been implemented directly on the silicon surface. Beside the interest for the FOOT experiment, the results in terms of cluster signal, signal-to-noise ratio, dynamic range of the readout chips, as well as long-term stability studies in terms of noise, are relevant also for other experiments where the use of thin sensors is crucial
    corecore