109 research outputs found

    Reflections of Medical Students on Visiting Chronically Ill Older Patients in the Home

    Full text link
    Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/66114/1/j.1532-5415.2006.00918.x.pd

    Assessment of diaphragm motion using ultrasonography in a patient with facio-scapulo-humeral dystrophy: A case report.

    Get PDF
    Diaphragm is the main inspiratory respiratory muscle and little is known about diaphragm ultrasound in facio-scapula-humeral muscular dystrophy, a neuromuscular disease characterized by an asymmetric skeletal muscle involvement. Diaphragm function evaluation DIAGNOSIS:: Diaphragm muscle weakness attested by the drop of vital capacity (VC) value from sitting position (74%) to supine position (46%). A diaphragm ultrasound was performed in supine position, from the anterior subcostal window OUTCOMES:: We found an opposite side to side hemi diaphragm displacement, either during sniff maneuver or during deep inspiration maneuver, showing a cranial abnormal reduced motion of the right hemi diaphragm whereas the left hemi diaphragm moved caudally. Diaphragm weakness may be present with an asymmetric pattern and an opposite motion during inspiration or sniff manoeuver in facio-scapula-humeral muscular dystrophy. A future study with a systematic evaluation of a greater number of FSHD1 patients will be necessary to characterize this population

    Reliability of home CPAP titration with different automatic CPAP devices

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>CPAP titration may be completed by automatic apparatus. However, differences in pressure behaviour could interfere with the reliability of pressure recommendations. Our objective was to compare pressure behaviour and effective pressure recommendations between three Automatic CPAP machines (Autoset Spirit, Remstar Auto, GK 420).</p> <p>Methods</p> <p>Sixteen untreated obstructive sleep apnea patients were randomly allocated to one of the 3 tested machines for a one-week home titration trial in a crossover design with a 10 days washout period between trials.</p> <p>Results</p> <p>The median pressure value was significantly lower with machine GK 420 (5.9 +/- 1.8 cm H<sub>2</sub>O) than with the other devices both after one night and one week of CPAP titration (7.4 +/- 1.3 and 6.6 +/- 1.9 cm H<sub>2</sub>O). The maximal pressure obtained over the one-week titration was significantly higher with Remstar Auto (12.6 +/- 2.4 cm H<sub>2</sub>O, Mean +/- SD) than with the two other ones (10.9 +/- 1.0 and 11.0 +/- 2.4 cm H<sub>2</sub>O). The variance in pressure recommendation significantly differed between the three machines after one night and between Autoset Spirit and the two other machines after 1 week.</p> <p>Conclusion</p> <p>Pressure behaviour and pressure recommendation significantly differ between Auto CPAP machines both after one night and one week of home titration.</p

    Randomised short-term trial of high-span versus low-span APAP for treating sleep apnoea

    Get PDF
    PURPOSE: Auto-titrating continuous positive airway pressure (APAP) devices were developed to improve treatment efficacy and compliance in patients with obstructive sleep apnoea syndrome (OSAS). Since there are insufficient data on the optimal pressure range setting, we aimed to compare the adherence, efficacy and tolerability of treatment with high-span versus low-span APAP. METHODS: Seventy-six newly diagnosed OSAS patients fulfilling the treatment criteria were randomised to receive high-span (HS, range 4-15cmH2O, n?=?38) or low-span (LS, range 8-12cmH2O, n?=?38) APAP. Patients were assessed at 1 and 3 months. RESULTS: Median Epworth sleepiness scale (ESS) was 13 (IQR, 6-16) and median apnoea-hypopnoea index (AHI) was 35.9 (IQR, 27.6-56.3). There were no significant differences in baseline demographic and clinical characteristics between groups. Overall, no significant differences were found at the first month assessment. After 3 months of therapy, we found again no differences in residual AHI or ESS. However, the group HS proved less adherent than group LS, respectively, with median 87 % (IQR, 60.5-97.5) versus 94 % (IQR, 80.0-98.3) of the nights using =4 h (P?=?0.014) and mean (±SD) usage 5.7?±?1.6 versus 6.4?±?1.2 h/night (P?=?0.049). The group HS reported more frequently nasal congestion, excessive oronasal dryness and nocturnal awakenings of at least moderate intensity, the latter with statistical significance (P?=?0.005). CONCLUSIONS: Both pressure ranges appear to be equally effective to correct AHI and to improve symptoms. Though, patients with high-span APAP were less compliant to treatment, raising issues about the tolerability of wide pressure range settings of these devices.T Pinto has received financial support from Linde and Vitalaire (Healthcare Providers) for attending symposia and honoraria for speaking at symposia from Philips. After the conclusion of the study, JC Winck has started working in a global position for Linde. The remaining authors declare that they have no conflict of interest

    Subjecting Elite Athletes to Inspiratory Breathing Load Reveals Behavioral and Neural Signatures of Optimal Performers in Extreme Environments

    Get PDF
    Background: It is unclear whether and how elite athletes process physiological or psychological challenges differently than healthy comparison subjects. In general, individuals optimize exercise level as it relates to differences between expected and experienced exertion, which can be conceptualized as a body prediction error. The process of computing a body prediction error involves the insular cortex, which is important for interoception, i.e. the sense of the physiological condition of the body. Thus, optimal performance may be related to efficient minimization of the body prediction error. We examined the hypothesis that elite athletes, compared to control subjects, show attenuated insular cortex activation during an aversive interoceptive challenge. Methodology/Principal Findings: Elite adventure racers (n = 10) and healthy volunteers (n = 11) performed a continuous performance task with varying degrees of a non-hypercapnic breathing load while undergoing functional magnetic resonance imaging. The results indicate that (1) non-hypercapnic inspiratory breathing load is an aversive experience associated with a profound activation of a distributed set of brain areas including bilateral insula, dorsolateral prefrontal cortex and anterior cingulated; (2) adventure racers relative to comparison subjects show greater accuracy on the continuous performance task during the aversive interoceptive condition; and (3) adventure racers show an attenuated right insula cortex response during and following the aversive interoceptive condition of non-hypercapnic inspirator

    Association between sleep duration and blood pressure in adolescents

    Get PDF
    In adults, sleep has an important role in the development of cardiovascular diseases. However, in young adolescents, the effect is unclear. The purpose of this cross-sectional study was to evaluate the association between sleep duration and blood pressure (BP) in subjects of 13 years of age. We evaluated 1771 adolescents as part of a population-based cohort (Epidemiological Health Investigation of Teenagers). Sleep duration was estimated based on the difference between self-reported usual bedtimes and wake-up times, and adolescents were classified into three categories: 8.5 h (reference class), >8.5 h and 8.5 and <9.5 h: OR=1.56, 95% CI 1.07–2.27; 9.5 h: OR=1.83, 95% CI 1.23–2.70). Among males, no significant association was found between sleep duration and BP. Sleep duration was positively associated with BP in both sexes, although after adjustment for potential confounders, this association was significant only for female adolescents
    corecore