50 research outputs found

    Clinical impact of molecular breast imaging as adjunct diagnostic modality in evaluation of indeterminate breast abnormalities and unresolved diagnostic concerns

    Get PDF
    Purpose Improvements in molecular breast imaging (MBI) have increased the use of MBI as adjunct diagnostic modality and alternative to MRI. We aimed to assess the value of MBI in patients with equivocal breast lesions on conventional imaging, especially in terms of its ability to rule out malignancy. Methods We selected patients who underwent MBI in addition to conventional diagnostics due to equivocal breast lesions between 2012 and 2015. All patients underwent digital mammography, target ultrasound and MBI. MBI was performed using a single-head Dilon 6800 gamma camera after administration of 600 MBq 99mTc-sestamibi. Imaging was reported according to BI-RADS classification and compared with pathology or follow-up of ≥6 months. Results Of 226 women included, pathology was obtained in 106 (47%) and (pre)malignant lesions were found in 25 (11%). Median follow-up was 5.4 years (IQR 3.9-7.1). Sensitivity was higher for MBI compared to conventional diagnostics (84% vs. 32%; P = 0.002), identifying malignancy in 21 and 6 patients, respectively, but specificity did not differ (86% vs. 81%; P = 0.161). Positive and negative predictive value were 43% and 98% for MBI and 17% and 91% for conventional diagnostics. MBI was discordant with conventional diagnostics in 68 (30%) patients and correctly changed diagnosis in 46 (20%) patients, identifying 15 malignant lesions. In subgroups with nipple discharge (N = 42) and BI-RADS 3 lesions (N = 113) MBI detected 7 of 8 occult malignancies. Conclusion MBI correctly adjusted treatment in 20% of patients with diagnostic concerns after conventional work-up, and could rule out malignancy with a high negative predictive value of 98%.</p

    Minimally invasive complete response assessment of the breast after neoadjuvant systemic therapy for early breast cancer (micra trial) : interim analysis of a multicenter observational cohort study

    Get PDF
    Background The added value of surgery in breast cancer patients with pathological complete response (pCR) after neoadjuvant systemic therapy (NST) is uncertain. The accuracy of imaging identifying pCR for omission of surgery, however, is insufficient. We investigated the accuracy of ultrasound-guided biopsies identifying breast pCR (ypT0) after NST in patients with radiological partial (rPR) or complete response (rCR) on MRI. Methods We performed a multicenter, prospective single-arm study in three Dutch hospitals. Patients with T1-4(N0 or N +) breast cancer with MRI rPR and enhancement <= 2.0 cm or MRI rCR after NST were enrolled. Eight ultrasound-guided 14-G core biopsies were obtained in the operating room before surgery close to the marker placed centrally in the tumor area at diagnosis (no attempt was made to remove the marker), and compared with the surgical specimen of the breast. Primary outcome was the false-negative rate (FNR). Results Between April 2016 and June 2019, 202 patients fulfilled eligibility criteria. Pre-surgical biopsies were obtained in 167 patients, of whom 136 had rCR and 31 had rPR on MRI. Forty-three (26%) tumors were hormone receptor (HR)-positive/HER2-negative, 64 (38%) were HER2-positive, and 60 (36%) were triple-negative. Eighty-nine patients had pCR (53%; 95% CI 45-61) and 78 had residual disease. Biopsies were false-negative in 29 (37%; 95% CI 27-49) of 78 patients. The multivariable associated with false-negative biopsies was rCR (FNR 47%; OR 9.81, 95% CI 1.72-55.89; p = 0.01); a trend was observed for HR-negative tumors (FNR 71% in HER2-positive and 55% in triple-negative tumors; OR 4.55, 95% CI 0.95-21.73; p = 0.058) and smaller pathological lesions (6 mm vs 15 mm; OR 0.93, 95% CI 0.87-1.00; p = 0.051). Conclusion The MICRA trial showed that ultrasound-guided core biopsies are not accurate enough to identify breast pCR in patients with good response on MRI after NST. Therefore, breast surgery cannot safely be omitted relying on the results of core biopsies in these patients

    A novel highly selective 5-HT6 receptor antagonist attenuates ethanol and nicotine seeking but does not affect inhibitory response control in Wistar rats

    No full text
    Recent studies suggest a potential role for 5-hydroxytryptamine(6) (5-HT6) receptors in the regulation of addictive behavior. In the present study, our aim was to investigate whether the novel highly selective 5-HT6 receptor antagonist compound (CMP) 42 affected nicotine and ethanol seeking behavior in Wistar rats. We have also studied whether CMP 42 had beneficial effects in a model of impulse control, as measured in the 5-choice serial reaction time task (5-CSRTT). Rats were trained to nose poke to receive intravenous infusions of nicotine or an ethanol drop. CMP 42 (3-30 mg/kg intraperitoneally, i.p.) was administered to investigate the effects on nicotine self-administration. Rats were also tested for cue-induced reinstatement of nicotine and ethanol seeking. In addition, the effects of CMP 42 were studied on the number of anticipatory responses in the 5-CSRTT. CMP 42 was effective in reducing nicotine self-administration and reinstatement of nicotine seeking at a dose of 30 mg/kg (i.p.). CMP 42 was also effective in reducing reinstatement of ethanol seeking (30 mg/kg i.p.). In contrast, CMP 42 did not affect anticipatory responding at doses tested, indicating no effects on impulse control. These results add to a body of evidence implicating the 5-HT6 receptor as a viable target for the control of drug abuse. Specifically, we demonstrated for the first time effects on nicotine self-administration and on nicotine and ethanol reinstatement. Further, these effects are probably not mediated by effects on impulse control
    corecore