278,404 research outputs found
Flow Induced by the Impulsive Motion of an Infinite Flat Plate in a Dusty Gas
Flow Induced by the Impulsive Motion of an Immite Flat Plate in a Dusty Gas. The problem of
flow induced by an infinite flat plate suddenly set into motion parallel to its own plane in an incompressible
dusty gas is of considerable physical interest in its own right as well as because of its close relation to the
non-linear, steady (constant-pressure) laminar boundary layer. Its solution provides complete and exact
information about modifications of the boundary layer growth and skin friction due to particle-fluid
interaction. Moreover, it provides a basis for judging the accuracy of approximations which have been
employed in more complex problems of viscous fluid-particle motion. The uncoupled thermal Rayleigh
problem for small relative temperature differences is directly inferred and this answers questions about the
modifications of the surface heat transfer rate and about the possibility of similarity with the velocity
boundary layer. Similarity is possible when, in addition to a Prandtl number of unity, the streamwise
relaxation processes are also similar
Penetration depth time history measurement method
A new method for measuring the depth time history of rigid body penetration into brittle materials under a deceleration of ~10^5 g. The method includes: sabot-projectile, sabot-projectile separation and penetration depth detection systems. Relatively small intrinsic time error (3%) and depth error (0.3–0.7 mm) results. Penetration depth time history in a series of 4140 steel projectile penetrations into a mortar are measured at velocities of 100 to 500 m/sec with sufficient accuracy such that differentiation with respect to time yields stopping force, via Newton's second law
Recommended from our members
Fabrication of a high sensitive Ag-nanoparticle substrate and its application to the detection of toxic substances
Surface Enhanced Raman Scattering (SERS) is typically observed with the substrate in a liquid medium and it has been proposed as a promising technique for detecting low levels of pollutants in liquids. A technique is presented for self-assembly to immobilize Ag nanoparticles (Ag-NPs), with diameters ranging from 100 to 800nm on a solid support. Experimental results have been obtained through experiments using Ag-NPs active substrates to detect Rhodamine 6G (R6G) and crystal violet in the deionized water. Further, the SERS spectrum and Raman spectrum of phoxim were also measured, showing the enhancement in the performance of the active substrate as a result
On radiative transfer in the low Reynolds number blunt body stagnation region at hypersonic speeds. Part 1 - Emission dominated case
Effect of radiative heat transfer in low Reynolds number hypersonic flow about blunt bod
Recommended from our members
Enhanced Raman Detection System based on a Hollow-core Fiber Probe design
This paper focus on an enhanced Raman-based detection probe and its performance evaluated. The probe employs a hollow-core fiber design to allow liquid micro-sample to be analyzed. The hollow-core fiber is used both to transmit the light signal used to excite the sample and to collect the Raman scattering signal received from the micro-sample under analysis. In order to maximize the performance of the system, various parameters have been studied experimentally, including the diameter and the height of the liquid sample in the probe. The aim has been optimizing both as a means to enhance the Raman scattering signal received from the liquid sample. As a result, a Raman-based detection probe using a reflector approach was developed and evaluated. This design enabling a greater area for interaction with the sample to be formed and to concentrate the excitation light into it. This then increases the efficiency of the light-liquid interaction and improves the collection efficiently of the forward Raman scattering light signal. With the use of this design, the detected Raman scattering signal was increased by a factor of 103~104 over what otherwise would be achieved. A key feature is that with the use of a hollow-core fiber to collect the liquid sample, only a very small volume is needed, making this well suited to practical applications where limited amounts of material are available e.g. biofluids or high value liquids. The system designed and evaluated thus provides the basis of an effective all-fiber Raman-based detection system, capable of being incorporated into portable analysis equipment for rapid detection and in-the-field use
Finite-Amplitude Instability of the Compressible Laminar Wake. Strongly Amplified Disturbances
The interaction between mean flow and finite‐amplitude disturbances in certain experimentally observed unstable, compressible laminar wakes is considered theoretically without explicitly assuming small amplification rates. Boundary‐layer form of the two‐dimensional mean‐flow momentum, kinetic energy and thermal energy equations and the time‐averaged kinetic energy equation of spatially growing disturbances are recast into their respective von Kármán integral form which show the over‐all physical coupling. The Reynolds shear stresses couple the mean flow and disturbance kinetic energies through the conversion mechanism familiar in low‐speed flows. Both the mean flow and disturbance kinetic energies are coupled to the mean‐flow thermal energy through their respective viscous dissipation. The work done by the disturbance pressure gradients gives rise to an additional coupling between the disturbance kinetic energy and the mean‐flow thermal energy. The compressibility transformation suggested by work on turbulent shear flows is not applicable to this problem because of the accompanying ad hoc assumptions about the disturbance behavior. The disturbances of a discrete frequency which corresponds to the most unstable fundamental component, are first evaluated locally. Subsequent mean‐flow and disturbance profile‐shape assumptions are made in terms of a mean‐flow‐density Howarth variable. The compressibility transformation, which cannot convert this problem into a form identical to the low‐speed problem of Ko, Kubota, and Lees because of the compressible disturbance quantities, nevertheless, yields a much simplified description of the mean flow
- …